• 제목/요약/키워드: Hydraulic Gun

검색결과 105건 처리시간 0.026초

친수환경 조성을 위한 연구 (A study for a hydrophilic environment creation)

  • 신문섭;이동주;유대성;강신중;이건탁
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.690-694
    • /
    • 2005
  • It is necessary that the construction of submerged breakwater could minimize and compensate the negative effect on the marine environment and ecosystem caused by the Saemangeum reclamation. The important merit of this proposal is that the space between Saemangeum embankment and submerged breakwater is expected to become nursery ground for fish and shellfishes. The purpose of this study was investigated hydraulic characteristic of submerged breakwater to investigate the possibility of mitigation in the fisheries ground by hydraulic experiment.

  • PDF

무선 전자식 장비를 이용한 지중열전도도 측정 기술 (Ground Thermal Conductivity Test with A Wireless Probe)

  • 김지영;이의준;장기창;강은철;고건혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2381-2384
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

  • PDF

살수식 여과조의 질산화작용에 대한 수리학적 부하량과 C/N 비의 영향 (Impacts of the Hydraulic Loading Rate and C/N Ratio on Nitrification in a Trickling Filter with Styrofoam Bead Media in Seawater)

  • 최태건;김병기;박정환
    • 한국수산과학회지
    • /
    • 제52권3호
    • /
    • pp.256-267
    • /
    • 2019
  • Styrofoam beads, which are relatively inexpensive and can provide a large specific surface area, were tested as filter media. Styrofoam beads with a diameter of $3{\pm}0.5mm$ were used; the specific surface area of the beads was $1,034m^2{\cdot}m^{-3}$. Five independent recirculating culture systems were used in the experiment. Each system consisted of one culture tank and three trickling bio-filters. Using the systems, nitrification efficiency was evaluated with respect to hydraulic loading rate (HLR) and carbon/nitrogen (C/N) ratio. The lowest ammonia and nitrogen concentrations were $0.84mg{\cdot}L^{-1}$ and $1.30mg{\cdot}L^{-1}$, respectively, observed at an HLR of $50.9m^3{\cdot}m^{-2}{\cdot}h^{-1}$. Nitrification efficiency in the culture tank was highest at a C/N ratio of 0, with ammonia and nitrite nitrogen concentrations of $0.32mg{\cdot}L^{-1}$ and $0.90mg{\cdot}L^{-1}$, respectively. Ammonia and nitrite nitrogen concentrations in the culture tank abruptly changed at C/N ratios ${\geq}3$.

실린더형 정전용량 센서 및 변위 측정시스템 설계 (Design of Stroke Measurement System and Cylinder-type Capactive Sensor)

  • 이재건;이인곤;박성균;홍익표
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.910-912
    • /
    • 2015
  • 본 논문에서는 중장비나 댐의 수문 등의 적용된 유압 실린더의 변위(stroke)를 검출하여 유압 실린더의 정밀제어 또는 자동화를 위한 정전용량 센서(Capacitive Sensor) 및 변위 검출 시스템을 설계하였다. 기존 실린더의 변위 검출 방식인 코일을 이용한 자기장 센서, LVDT 센서 등은 높은 정확도에 비해 충격 및 진동 완화 또는 센서 보호 하우징(Housing) 등 부수적인 설비에 따른 높은 비용, 큰 부피와 같은 문제가 있다. 따라서 이러한 개선하기 위해 유압 실린더 내의 직접 적용되어 실린더의 변위 검출이 가능한 정전용량 센서를 설계하였으며, 설계한 정전용량 센서를 통하여 실린더의 변위에 따른 커패시턴스 값을 검출하여 실린더 위치 측정이 가능한 시스템을 설계 및 검증 하였다.

  • PDF

Thermal-hydraulic safety analysis of radioisotope production in HANARO using MCNP6 and COMSOL multiphysics: A feasibility study

  • Taeyun Kim;Bo-Young Han;Seongwoo Yang;Jaegi Lee ;Gwang-Min Sun;Byung-Gun Park;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3996-4001
    • /
    • 2023
  • The High-flux Advanced Neutron Application Reactor (HANARO) produces radioisotopes (RIs) (131I, 192Ir, etc.) through neutron irradiation on various RI production targets. Among them, 177Lu and 166Ho are particularly promising owing to their theranostic characteristics that facilitate simultaneous diagnosis and treatment. Prior to neutron irradiation, evaluating the nuclear heating of the RI production target is essential for ensuring the thermal-hydraulic safety of HANARO. In this study, the feasibility of producing 177Lu and 166Ho using irradiation holes of HANARO was investigated in terms of thermal-hydraulic safety. The nuclear heating rates of the RI production target by prompt and delayed radiation were calculated using MCNP6. The calculated nuclear heating rates were used as an input parameter in COMSOL Multiphysics to obtain the temperature distribution in an irradiation hole. The degree of temperature increase of the 177Lu and 166Ho production targets satisfied the safety criteria of HANARO. The nuclear heating rates and temperature distribution obtained through the in silico study are expected to provide valuable insight into the production of 177Lu and 166Ho using HANARO.

요동형 쌍원통 유압펌프내의 유동장 해석에 관한 연구 (Investigation of new in the Oil-Hydraulic Pump Consisting of Swing Twin-Cylinder)

  • 심우건;김기선
    • 한국진공학회지
    • /
    • 제14권1호
    • /
    • pp.7-16
    • /
    • 2005
  • 두 개의 쌍원통 실린더를 구성하고 있는 기름-물 펌프는 차세대 저진공 펌프로의 활용이 가능하다. 하지만 설계개선을 위한 유동 해석 결과가 충분하지 않다. 경제적 측면에서 상업화 이전에 수치해석 방법에 의한 유동해석이 요구되고 있다. 유동 해석에 사용되는 상업용 코드(Fluent)을 사용하여 펌프의 설계에 필요한 자료를 제공하였다. 쌍원통 실린더와 고정 실린더 사이의 속도와 압력 분포 등의 유동변수를 분석하기 위하여 2차원 해석을 수행하였다. 본 수치해석 방법은 쌍원통 실린더로 구성된 펌프의 성능향상에 유용하게 사용할 수 있다.

시설물별 태풍에 따른 피해특성 및 원인분석 (The Analysis of Damage Characteristic and Cause on Infrastructures by Typhoon)

  • 신창건;이종영;김석조;지영환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1602-1610
    • /
    • 2005
  • In this study was investigated and analyzed of damage characteristics for infrastructures by typhoon that have been many occur. The objective Structures were the road and hydraulic structure. The road structure was included the cut-slopes, retaining walls and bridges. The hydraulic structure is divided with the dike, small-scale dam, reservoir and floodgate. The analysis result of the bridge damage cause is river bottom height increase and passage ability decrease. The principal damage reasons of the cut-slope structure are weakening the ground due to the localized torrential downpour and drainage defective. Also, the principal damage reasons of the small-scale dam, reservoir, dike and the floodgate are continuous collapse of dike beside the floodgate.And we divided a typhoon damage occurrence cause with artificial and natural. As the result of analysis, the many damage occurrence cause will be removed by system improvement and technical development.

  • PDF

절취사면 용출수의 효율적인 배제에 대한 사례연구 (A Study Of Case On Prescription Of Spring Out Water In Cut Slope)

  • 신창건;서정유;홍남경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1095-1099
    • /
    • 2009
  • 절취사면의 붕괴 발생은 지질 및 지형적인 요인과 수리적인 요인 등 매우 다양한 요인들이 복합적으로 작용하여 발생한다. 이 중 수리적인 요인은 지질 및 지형적인 요인과 더불어 사면의 안정성 및 도로통행의 위험성에 중요한 요인으로 작용하고 있다. 사면내의 물은 전단강도의 저하 및 활동력의 증가를 시키며, 이는 사면의 붕괴를 유발한다. 또한 지하수의 용출수는 사면의 안정성 이외에 추가적인 도로유지관리에 문제를 일으킨다. 효율적인 방법으로 용출수 및 지표수를 제어한 사례를 제시하여 실무에 좋은 자료로 이용되고, 더 많은 사례연구가 이루어져 유사한 현장에 적용될 많은 자료가 필요할 것으로 판단된다.

  • PDF

Implementation of a new empirical model of steam condensation for the passive containment cooling system into MARS-KS code: Application to containment transient analysis

  • Lee, Yeon-Gun;Lim, Sang Gyu
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3196-3206
    • /
    • 2021
  • For the Korean design of the PCCS (passive containment cooling system) in an innovative PWR, the overall thermal resistance around a condenser tube is dominated by the heat transfer coefficient of steam condensation on the exterior surface. It has been reported, however, that the calculated heat transfer coefficients by thermal-hydraulic system codes were much lower than measured data in separate effect tests. In this study, a new empirical model of steam condensation in the presence of a noncondensable gas was implemented into the MARS-KS 1.4 code to replace the conventional Colburn-Hougen model. The selected correlation had been developed from condensation test data obtained at the JERICHO (JNU Experimental Rig for Investigation of Condensation Heat transfer On tube) facility, and considered the effect of the Grashof number for naturally circulating gas mixture and the curvature of the condenser tube. The modified MARS-KS code was applied to simulate the transient response of the containment equipped with the PCCS to the large-break loss-of-coolant accident. The heat removal performances of the PCCS and corresponding evolution of the containment pressure were compared to those calculated via the original model. Various thermal-hydraulic parameters associated with the natural circulation operation through the heat transport circuit were also investigated.