환기 병용형 냉난방 시스템 설계 및 현장 적용 사례 연구 (A Case Study of Hybrid Air Conditioning and Ventilation System)

  • 이홍철;황인주;신현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.89-94
    • /
    • 2008
  • In this study it was evaluated that hybrid air conditioning and ventilation system to reduce energy consumption and keep on comfortable indoor environment in an underground shopping center. Room temperature by hybrid HAVC system was controled as $1.8{\sim}2.1^{\circ}C$ low and indoor humidity was controled as $4.1{\sim}5.0%RH$ low, and response was fast in $2.0{\sim}2.5$ times compared with conventional system. And also transportation efficiency of hybrid HVAC system was improved in about 27%, and total energy consumption rate of hybrid HVAC system is decreased in 16% compared with conventional system.

  • PDF

고연성 하이브리드 FRP 리바의 화학적 환경 노출 후 부착 성능 (Bond Performance of Ductile Hybrid FRP Rebar After Chemical Environmental Exposures)

  • 원종필;박찬기;서정민;공태웅;성상경;최석원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.333-336
    • /
    • 2004
  • In this study focuses on bond properties of hybrid FRP rebar after chemical environmental exposure. Hybrid FRP rebar bond specimens were subjected to four type of exposure conditions. Bond properties were investigated by direct bond test. Bond test results, hybrid FRP rebars were found to have better bond strength with concrete than currently using GFRP rebar. Also, hybrid FRP rebar had more than about $80\%$ in bond strength of steel rebar.

  • PDF

RFID 시스템을 위한 저전력 Hybrid ARQ 방식 (A Low-Power Hybrid ARQ Scheme for RFID System)

  • 최성혜;조인휘
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 한국컴퓨터종합학술대회 논문집 Vol.32 No.1 (A)
    • /
    • pp.265-267
    • /
    • 2005
  • RFID 시스템에서 소형화 추세 및 배터리 사용에 따라 태그 및 리더의 전송 전력을 최소화할 수 있는 저전력 설계가 반드시 필요하다. 또한 리더와 Tag는 무선으로 통신을 수행하며, 동시에 Tag는 이동성을 가지므로 에러율이 유선방식에 비해 상당히 높다. 그러나 현재 ISO표준에서는 에러발생시 MAC계층에서 단지 CRC체크 후 재전송을 하는 방식으로 에너지 효율성 및 전송효율이 떨어진다. 본 논문에서는 이 같은 문제를 해결하기 위해서 유통 물류 등에 사용되는 900MHz대역의 RFID시스템에서 에너지 소모 최소화와 신뢰성을 보장할 수 있는 방법으로 Hybrid ARQ를 제안한다. 기존의 Hybrid ARQ를 개선시켜 에너지 효율성을 고려한 최적패킷 길이를 사용하고, 에너지 소모가 적은 BCH Code를 채택한다. 성능 분석 및 시뮬레이션 결과, 제안하는 Hybrid ARQ 방식이 기존의 전송방식보다 에너지 효율성 및 신뢰성을 향상시킴을 보여준다.

  • PDF

차륜형 이동로봇의 자율 벽면-주행을 위한 하이브리드 제어 (Autonomous Wall-Following of Wheeled Mobile Robots using Hybrid Control Approach)

  • 임미섭;임준홍;오상록
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3105-3107
    • /
    • 1999
  • In this paper, we propose a new approach to autonomous wall-following of wheeled mobile robots using hybrid control system. The hybrid control approach IS introduced to the motion control of nonholonomic mobile robots in the Indoor navigation problems. In hybrid control architecture, the discrete states are defined by the user-defined constraints, and the reference motion commands are specified In the abstracted motions. The hybrid control system applied to motion planning and autonomous navigation with obstacle avoidance In indoor navigation problem. Simulation results show that it is an effective method for the autonomous navigation in indoor environments.

  • PDF

실리카-타이타니아 하이브리드 코팅막의 제조 및 특성평가 (Fabrication and characterization of silica-titania hybrid film using silane treated $TiO_2$ sol)

  • 한동희;강동준;김석준;강동필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.553-554
    • /
    • 2007
  • By sol-gel method, we have fabricated silica-titania hybrid film using silane treated colloidal $TiO_2$ and characterized the film through FT-IR, TGA, UV-VIS and AFM. The silica-titania hybrid film showed Ti-O-Si chemical bond at FT-IR peak of $910{\sim}940cm^{-1}$. The fabricated hybrid film showed thermal stability of around $350^{\circ}C$(5wt% loss temperature) and transparency more than 90%. In addition, the good surface smoothness was confirmed by AFM. Therefore, the silica-titania hybrid film with outstanding properties can be potential for application in electronics and displays.

  • PDF

층별변위 유한요소법에 기초한 점탄성층을 갖는 원통형 복합적층 패널의 진동해석 (Vibration Analyses of Cylindrical Hybrid Panel With Viscoelastic Layer Based On Layerwise Finite Elements)

  • 오일권;성태홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.772-778
    • /
    • 2005
  • Based on a full layerwise displacement shell theory, the vibration and damping characteristics of cylindrical sandwiched panels with viscoelastic layers are investigated. The transverse shear deformation and the normal strain of the cylindrical hybrid panels are fully taken into account for the structural damping modelling. The present finite element model is formulated by using Hamilton's virtual work principle and the cylindrical curvature of hybrid panels is exactly modeled. Modal loss factors and frequency response functions are analyzed for various structural parameters of cylindrical sandwich panels. Present results show that the full layerwise finite element method can accurately predict the vibration and damping characteristics of the cylindrical hybrid panels with surface damping treatments and constrained layer damping.

  • PDF

선호도 기반 최적화 방법을 사용한 복합 구조 제어 시스템 설계 (Hybrid Structural Control System Design Using Preference-Based Optimization)

  • 박원석;박관순;고현무
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2006
  • An optimum design method for hybrid control systems is proposed in this study. By considering both active and passive control systems as a combined or a hybrid system, the optimization of the hybrid system can be achieved simultaneously. In the proposed approach, we consider design parameters of active control devices and the elements of the feedback gain matrix as design variables for the active control system. Required quantity of the added dampers are also treated as design variables for the passive control system. In the proposed method, the cost of both active and passive control devices, the required control efforts and dynamic responses of a target structure are selected as objective functions to be minimized. To effectively address the multi-objective optimization problem, we adopt a preference-based optimization model and apply a genetic algorithm as a numerical searching technique. As an example to verify the validity of the proposed optimization technique, a wind-excited 20-storey building with hybrid control systems is used and the results are presented.

  • PDF

공동주택용 하이브리드 환기설비에 관한 연구 (A Study of Hybrid Ventilation System applying to an Apartment House)

  • 이성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF

상온양생에 의한 하이브리드 섬유를 혼입한 50MPa급 3성분계 무시멘트 모르타르 강도발현 (50MPa Ternary Non-Cement Mortar Strength Development Mixing with Hybrid Fibers Cured by Room Temperature)

  • 조성원;조성은;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.179-180
    • /
    • 2020
  • CO2 emissions are caused by cement manufacturing process. To solve this problem construction industry are using industrial by-products to replace cement. In this study, three different industrial by products were used and mixed with hybrid fibers to enhance bond strength. As the result, Regardless of the mixing rate of silica fume, the compressive strength of the ternary non cent mortar was higher than that of OPC and binary. And mixed hybrid fibers cured by room temperature compressive strength were 23% higher than those without hybrid fibers.

  • PDF

하이브리드 미터를 이용한 양생조건에 따른 응결 및 압축강도 추정 (Estimation of Setting Time and Compressive Strength of the Concrete According to Curing Conditions Using a Hybrid Meter)

  • 박재웅;정준택;임군수;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.187-188
    • /
    • 2023
  • This study aimed to evaluate a feasibility of estimating setting time and compressive strength of curing conditions using a Hybrid meter. As a result, It was determined that the measured hardness value at the initial set, final set and at 5MPa of the Hybrid meter were not affected by curing conditions. And the Hybrid meter(A) is confirmed to have a higher correlation, so it is judged to be more suitable for pratical use.

  • PDF