• 제목/요약/키워드: Hybrid imaging

검색결과 122건 처리시간 0.028초

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권4호
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

수동형 SONAR 시스템을 사용한 지하 진원지의 추정 (Position estimation of underground acoustic source origin using a passive SONAR system)

  • 장순석;이제형;안흥구;최현호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.103-108
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about loom underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구 (The Study on Composition ratio of Iodine in Hybrid X-ray Sensor)

  • 공현기;박지군;최장용;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

뇌척추질환 전용 수술중 CT 광학융합 시스템에 관한 연구 (A Study on Intraoperative CT Optical Hybrid System for Brain and Spine Disease)

  • 정창원;김지언;김규겸;김태훈;유종현;전홍영;홍지민;김대원;윤권하
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 춘계학술발표대회
    • /
    • pp.506-507
    • /
    • 2017
  • 최근 의료영상진단기기 개발 동향은 ICT 기술과 접목하는 융합진단 영상기기 개발연구로 활발하게 진행되고 있다. 특히, 수술중 CT의 개발은 임상적 미수요 충족을 위한 최첨단 기술개발로 위급한 환자를 의료영상 촬영을 위한 지정장소로 이동해야하는 문제점을 해결하여 현장 어느 곳에서 촬영할 수 있고, 환자의 다양한 의료영상을 융합하여 환자의 병변에 대한 명확한 위치와 형태 그리고 상태를 파악할 수 있도록 하며 수술을 위한 네비게이션 기능을 포함한다. 본 논문에서는 수술중 CT에 대한 설계한 사항에 대해 기술하고자 한다. 제안한 시스템의 개발은 다양한 임상현장에서 신속하게 진단과 수술을 지원할 수 있을 것으로 기대하고 있다.

Magnetic Resonance Imaging: Historical Overview, Technical Developments, and Clinical Applications

  • Jahng, Geon-Ho;Park, Soonchan;Ryu, Chang-Woo;Cho, Zang-Hee
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.35-53
    • /
    • 2020
  • The authors congratulate the cerebrations for the 30 years of the Korean Society of Medical Physics (http://www.ksmp.or.kr/). The paper is published to recognize the anniversary. Geon-Ho Jahng invited Professor Z. H. Cho to join to submit this manuscript because he has been one of the leaders in the field of magnetic resonance imaging (MRI) during the last 40 years. In this review, we describe the development and clinical histories of MRI internationally and domestically. We also discuss diffusion and perfusion MRI, molecular imaging using MRI and MR spectroscopy (MRS), and the hybrid systems, such as positron emission tomography-MRI (PET-MRI), MR-guided focused ultrasound surgery (MRgFUS), and MRI-guided linear accelerators (MRI-LINACs). In each part, we discuss the historical evolution of the developments, technical developments, and clinical applications.

Design and fabrication of plastic diffractive / refractive hybrid lenses for image communication

  • Choi, Ho-Young;Yeo, Sang-Ok;Song, Jin-Han;Moon, Hee-Jong;Park, Man-Hyo;Park, Myung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.163-164
    • /
    • 2000
  • We discuss the design and fabrication of CCD or C-MOS imaging lenses with hybrid diffractive / refractive optics. The hybrid lenses are made of optical grade plastic materials. We have been able to significantly reduce the number of elements while maintaining very high optical quality. This paper describes the conception, design, fabrication and evaluation of hybrid lenses in comparison with conventional refractive lenses. The new lens has excellent optical quality, very light weight, compact size and low manufacturing cost.

  • PDF

소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용 (Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.64-72
    • /
    • 2002
  • 목적 : 소아 뇌 질환에서의 자기공명분광법의 임상적 적용에 있어서 단일화적소 양성자 자기공명분광법과 고식적 이차원 양성자 자기공명분광법에 비해 혼성 이차원 양성자 자기공명분광법이 가지는 장점에 대하여 알아보고자 하였다. 대상 및 방법 : 생후 3일에서 15세까지의 79명의 소아 (정상소아 36명, 저산소성-허혈성 뇌 손상 10명, 대사성 질환 20명, 뇌막염-뇌염 3명, 뇌종양 7명, 신경섬유종증 1명, Sturge-Weber 증후군 1명, lissencephaly 1명)를 대상으로 81회의 혼성 이차원 양성자 자기공명분광검사를 시행하였다. 성인자원자(n=5)에서 단일화적소 양성자 자기공명분광법, 고식적 이차원 양성자 자기공명분광법, 그리고 혼성 이차원 양성자 자기공명분광법 모두를 실시하였고, 환아군 중 일부(n=12)에서 PRESS기법을 이용한 단일화적소 분광법과 혼성 이차원 양성자 자기공명 분광법을 함께 시행하였다. 1.5-T 초전도영상장치 하에서 standard head quatrature coil을 이용하여 양성자 자기공명분광을 얻었다. Phase encoding step은 16$\times$16으로 하였고, FOV는 환자 뇌의 크기에 따라 다양하게 하였으며, FOV내의 혼성 관심 체적 (hybrid VOI)은 $75{\times}75{\times}15{\;}\textrm{mm}^3$ 또는 그 이하로 함으로써 원하지 않는 지방에 의한 신호를 없애도록 하였다. PRESS기법 (TR/TE= 1,500 msec/135 또는 270 msec)을 적용하였고, 물에 의한 신호를 억제하기 위하여 chemical shift selective saturation pulse를 사용하였다. 혼성 이차원 양성자 자기공명분광검사의 획득시간(data acquistion time)과 분광의 질(spectral quality)을 단일화적소 양성자 자기공명분광법과 고식적이차원양성자 자기공명분광법의 그것과 비교하였다. 결과: 혼성 이차원 양성자 자기공명분광법은 79명의 소아 전 예에서 성공적으로 시행되었다. 단일화적소 양성자 자기공명분광법의 획득시간은 4.3분인 반면에, 혼성 이차원 양성자 자기공명분광법의 획득시간(data acquition time)은 6분 미만으로, 이는 소아의 뇌영상용으로 쓰기에 충분히 짧은 소요시간이었다. 혼성 이차원 양성자 자기공명분광법에 의한 분광은 단일화적소 자기공명분광법에 의한 분광과 거의 비슷한 민감도와 분광분해 능을 나타내었으며, 반면에 고식적인 이차원 양성자 자기공명분광법에 의한 분광보다는 훨씬 우수하였다.

  • PDF

비정질 셀레늄 기반에서 CsI:Na 응용을 위한 Na의 조성비 연구 (The study of Na Doping rate for application CsI:Na in the amorphous selenium)

  • 차병열;박지군;강상식;이규홍;남상희;최흥국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.412-414
    • /
    • 2003
  • This paper is about research of scintillator layer, which is used for Hybrid method to increase electric signals in a-Se, the material of Direct method. In case of the thermal evaporation, CsI has column structure which is an disadvantage as scintillator. But it decreases scattering of incident X-ray, has better Light output intensity than other scintillation materials. CsI was made by Thermal evaporation. The Doping material, Na, 0.1, 0.3, 0.5, 0.7g were added in each sample. Analysis of absorbed wavelength, PL(Photoluminescence), Light output intensity, SEM, and XRD analysis were performed to analyze optical characteristics. Doping rate of CsI:Na to use as scintillation layer in a-Se based detector could be optimized.

  • PDF