• Title/Summary/Keyword: Hybrid bus

Search Result 111, Processing Time 0.022 seconds

A Novel Algorithm for Optimal Location of FACTS Devices in Power System Planning

  • Kheirizad, Iraj;Mohammadi, Amir;Varahram, Mohammad Hadi
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.177-183
    • /
    • 2008
  • The particle swarm optimization(PSO) has been shown to converge rapidly during the initial stages of a global search, but around global optimum, the search process becomes very slow. On the other hand, the genetic algorithm is very sensitive to the initial population. In fact, the random nature of the GA operators makes the algorithm sensitive to initial population. This dependence to the initial population is in such a manner that the algorithm may not converge if the initial population is not well selected. In this paper, we have proposed a new algorithm which combines PSO and GA in such a way that the new algorithm is more effective and efficient and can find the optimal solution more accurately and with less computational time. Optimal location of SVC using this hybrid PSO-GA algorithm is found. We have also found the optimal place of SVC using GA and PSO separately and have compared the results. It has been shown that the new algorithm is more effective and efficient. An IEEE 68 bus test system is used for simulation.

A Novel Variable-Speed Renewable-Energy Generation System of Induction Generator and PWM Converter for Small-Scale Hybrid Power Applications

  • Ahmed, Tarek;Nishida, Katsumi;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1339-1342
    • /
    • 2005
  • This paper presents a simple AC-DC power conditioner for a squirell-cage induction generator(IG) operating under variable shaft speeds. The necessary reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM power converter size. A simple control compensating for changes in the electrical loads as well as the variation in speed was developed to regulate the voltages of the IG system by controlling the rotor flux through its reactive and active currents control implementation. This proposed power conditioning scheme can be used efficiently as a wind power generation system where the output voltage of the IG is maintained constant voltage despite the variable frequency and the DC bus voltage of the PWM converter can be used for either DC applications such as battery charging or AC power applications with 60/50 Hz by connecting a stand alone inverter. The experimental and simulated operating performance results of a 5 kW IG scheme at various speeds and leads are presented.

  • PDF

Analysis System for Practical Dynamic Load with Hybrid Method under Random Frequency Vibration (불규칙 가진시 하이브리드기법을 이용한 실동하중 해석시스템)

  • Song, Joon-Hyuk;Yang, Sung-Mo;Kang, Hee-Yong;Yu, Hyo-Sun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.33-38
    • /
    • 2008
  • Most structures of vehicle are composed of many substructures connected to one another by various types of mechanical joints. In vehicle engineering, it is important to study these jointed structures under random frequency vibration for the evaluations of fatigue life and stress concentration exactly. It is rarely obtained the accurate load history of specified positions in a jointed structure because of the errors such as modeling, measurement, and etc. In the beginning of design, exact load data are actually necessary for the fatigue strength and life analysis to minimize the cost and time of designing. In this paper, the hybrid method of practical dynamic load determination is developed by the combination of the principal stresses from F. E. Analysis and test of a jointed structure. Least square pseudo inverse matrix is adopted to obtain an inverse matrix of analyzed stresses matrix. The error minimization method utilizes the inaccurate measured error and the shifting error that the whole data is stiffed over real data. The least square criterion is adopted to avoid these errors. Finally, to verify the proposed system, a heavy-duty bus is analyzed. This measurement and prediction technology can be extended to the different jointed structures.

A Study on the Parallel Routing in Hybrid Optical Networks-on-Chip (하이브리드 광학 네트워크-온-칩에서 병렬 라우팅에 관한 연구)

  • Seo, Jung-Tack;Hwang, Yong-Joong;Han, Tae-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.8
    • /
    • pp.25-32
    • /
    • 2011
  • Networks-on-chip (NoC) is emerging as a key technology to overcome severe bus traffics in ever-increasing complexity of the Multiprocessor systems-on-chip (MPSoC); however traditional electrical interconnection based NoC architecture would be faced with technical limits of bandwidth and power consumptions in the near future. In order to cope with these problems, a hybrid optical NoC architecture which use both electrical interconnects and optical interconnects together, has been widely investigated. In the hybrid optical NoCs, wormhole switching and simple deterministic X-Y routing are used for the electrical interconnections which is responsible for the setup of routing path and optical router to transmit optical data through optical interconnects. Optical NoC uses circuit switching method to send payload data by preset paths and routers. However, conventional hybrid optical NoC has a drawback that concurrent transmissions are not allowed. Therefore, performance improvement is limited. In this paper, we propose a new routing algorithm that uses circuit switching and adaptive algorithm for the electrical interconnections to transmit data using multiple paths simultaneously. We also propose an efficient method to prevent livelock problems. Experimental results show up to 60% throughput improvement compared to a hybrid optical NoC and 65% power reduction compared to an electrical NoC.

Study on the Optimization of Hybrid Network Topology for Railway Cars (철도 차량용 하이브리드 네트워크 토폴로지 최적화 연구)

  • Kim, Jungtai;Yun, Ji-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.27-34
    • /
    • 2016
  • In the train system, railway vehicles are connected in a line. Therefore, this feature should be considered in composing network topology in a train system. Besides, inter-car communication should be distinguished from in-car communication. As for the inter-car communication, the hybrid topology was proposed to use rather than the conventional ring, star, daisy-chain, and bus topologies. In the hybrid topology, a number of cars are bound to be a group. Then star topology is used for the communication in a group and daisy-chain topology is used for the communication between groups. Hybrid topology takes the virtue of both star and daisy-chain topologies. Hence it maintains communication speed with reducing the number of connecting cables between cars. Therefore, it is important to choose the number of cars in a group to obtain higher performance. In this paper, we focus on the optimization of hybrid topology for railway cars. We first assume that the size of data and the frequency of data production for each car is identical. We also assume that the importance for the maximum number of cables to connect cars is variable as well as the importance of the communication speed. Separated weights are granted to both importance and we derive the optimum number of cars in a group for various number of cars and weights.

Development of a 100kW charging infra for electrical bus (전기버스용 100kW급 충전인프라 개발)

  • Lee, Chung-Woo;Oh, Seung-Hun;Lee, Yun-Jae;Choi, Eun-Sik;Kang, Byung-Kwan;Ryu, Kang-Yeul;Kim, Hee-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.117-118
    • /
    • 2013
  • Recent global warming to the promotion of electric vehicles (EV), plug-in hybrid (PEV), including the next generation of cars and solar power, wind power and other renewable energy, and next-generation power grid (smart grid) are getting attention. In addition, the system utilizes the battery life in the industry and the convenience of a variety of social systems, economics, environmental impact, and the inherent potential to change significantly, and you can not walk into a next-generation industrial strategy and the need increases more and more present, and its early commercialization In order to do this, as well as a key energy source, the battery charger for charging efficiency technologies is essential. In this paper, fast charge multiple battery modules and optional modules that can charge distribution charge will be introduced.

  • PDF

Basic Design of Phosphoric Acid Fuel Cell/Battery Hybrid Vehicle (인산형 연료전지/축전지 복합 구동 자동차 개념 설계)

  • Lee, Bong-Do;Lee, Won-Yong;Shin, Dong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.59-61
    • /
    • 1996
  • Fuel cell systems offer high efficiencies for energy conservation for transportation application. In addition, they can operate on alcohols and alternative fuels, while producing little or no noxious emissions. The goal of the fuel cell in transportation should be research and commercialization of fuel cell vehicles as economic competitors for internal combustion engine vehicle. The objective of the present study is to analyze feasibility of the fuel cell/battery combination as a power source for a bus.

  • PDF

Radial Basis Function Neural Network for Power System Transient Energy Margin Estimation

  • Karami, Ali
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.468-475
    • /
    • 2008
  • This paper presents a method for estimating the transient stability status of the power system using radial basis function(RBF) neural network with a fast hybrid training approach. A normalized transient energy margin(${\Delta}V_n$) has been obtained by the potential energy boundary surface(PEBS) method along with a time-domain simulation technique, and is used as an output of the RBF neural network. The RBF neural network is then trained to map the operating conditions of the power system to the ${\Delta}V_n$, which provides a measure of the transient stability of the power system. The proposed approach has been successfully applied to the 10-machine 39-bus New England test system, and the results are given.

A Study on the Performance Enhancement of HVDC System Using Hybrid Filter and Energy Recovery Filter (11차/13차 고조파를 동시에 제거하는 Single Tuned 필터)

  • Kim C.K.;Yang B.M.;Jeong G.J.;Ahan J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.717-721
    • /
    • 2003
  • Two non-conventional HVDC converter arrangements are compared. These include the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. Results show that both options have comparable steady state and transient performance. Danger of ferroresonance with the CSCC option is eliminated by controlling the amount of series compensation. The dynamic performance simulations is peformed by PSCAD/EMTDC

  • PDF

Transient Stability Assessment Using Improved SIME (개선된 SIME법을 이용한 과도 안정도 평가)

  • Lee, Jong-Seock;Ahn, Tae-Hyung;Yang, Jung-Dae;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.258-260
    • /
    • 1999
  • The Single Machine Equivalent(SIME) is a hybrid method resulting from the coupling of a time-domain program with the equal-area criterion. This paper presents the efficient filtering algorithm using improved SIME for Transient Stability Assessment. The main feature of the method is cascading contingency filtering. First contingency filtering is conducted by using the first-swing stability of equivalent One Machine Infinite Bus(OMIB) system. This stability is evaluated by checking its time trajectory. Selected cases through the first step are assessed on the second step using SIME under the detailed model of power systems. The efficiency of the algorithm is tested on PSS/E test system.

  • PDF