• Title/Summary/Keyword: Hybrid Storage System

Search Result 327, Processing Time 0.026 seconds

The Small Photovoltaic power supply using Hybrid Supercapacitor (하이브리드 커패시터를 적용한 소형 태양광 전원장치)

  • Kim, Tae-Yeop
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.826-831
    • /
    • 2019
  • The stand-alone photovoltaic power systems are widely used for lighting equipment and CCTV. In order for these devices to be competitive, the life of power storage devices such as batteries is very important. The characteristic Hybrid supercapacitor is the high power density and long life. We have proposed a stand-alone photovoltaic power system that uses hybrid supercapacitor. The charge and discharge characteristics and the internal resistance of the hybrid capacitor were measured to configure the power converter. A stable maximum output point tracking control algorithm is proposed even with the change in solar radiation. In order to verify the validity of the proposed system, a prototype was fabricated and tested using a 18W hybrid capacitor and a 10W solar cell.

Study of Operation Strategy for Hybrid PEM Fuel Cell and Supercapacitor (고분자 전해질 연료전지와 슈퍼캐패시터 하이브리드 시스템의 운전 전략에 관한 연구)

  • Park Kwang-Jin;Ji Hyun-Jin;Bae Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.756-763
    • /
    • 2006
  • PEMFC has several technical problems such as water management, long term stability and performance degradation as. PEMFC has been studied not only to solve water management, but also to generate power in stable manner to system by using a hybrid system with auxiliary energy storage device. The purpose of this study is to couple PEMFC with supercapacitor to make a hybrid system and to design and test control strategies for stable power generation in case of changing output power. The polarization curve and dynamic behaviors while changing power were investigated to find out characteristics of PEMFC stack. A DC/DC converter was fabricated in order to increase fuel cell and supercapacitor voltage and to charge supercapacitor. We found that the operation strategy 2 was recommended to the system because of solving water management problem and increasing the dynamic behavior.

Optimal unidirectional grid tied hybrid power system for peak demand management

  • Vineetha, C.P.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.47-68
    • /
    • 2016
  • A well designed hybrid power system (HPS) can deliver electrical energy in a cost effective way. In this paper, model for HPS consisting of photo voltaic (PV) module and wind mill as renewable energy sources (RES) and solar lead acid battery as storage device connected to unidirectional grid is developed for peak demand reduction. Life time energy cost of the system is evaluated. One year hourly site condition and load pattern are taken into account for analysing the HPS. The optimal HPS is determined for least life time energy cost subject to the constraints like state of charge of the battery bank, dump load, renewable energy (RE) generation etc. Optimal solutions are also found out individually for PV module and wind mill. These three systems are compared to find out the most feasible combination. The results show that the HPS can deliver energy in an acceptable cost with reduced peak consumption from the grid. The proposed optimization algorithm is suitable for determining optimal HPS for desired location and load with least energy cost.

Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid (독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석)

  • Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

Design and Construction Experiences of Solar Thermal Chemical Reaction Hybrid Power Generation (태양열 화학반응 복합발전시스템의 설계 및 시공 사례)

  • Lee, Sang-Nam;Kang, Yong-Heack;Kim, Jin-Soo;Yoon, Hwan-Ki;Yu, Chang-Kyun;Kim, Jong-Kyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.688-692
    • /
    • 2007
  • Solar thermal power generation allows additional benefits of cheap thermal storage and easy hybridization with other fossil fuel-driven power generation. KIER has been performing the project for solar thermal chemical reaction hybrid power generation. The project is to build and operate the first solar thermal chemical reaction hybrid power generation system in Korea. For concentrating solar thermal energy $m^2$ dish type concentrator was adapted and a heliostat is installed for reflecting horizontal insolation to the dish concentrator. At the moment building the dish concentrator including mirror and heliostat with sun tracking system was completed and it's performance are being closely evaluated. This paper will introduce some detailed designs and construction procedures which we have experienced so far.

  • PDF

DC Common Method of Hybrid PCS Overseas Demonstration Operation (DC Common 방식 Hybrid PCS 해외 실증 운전)

  • Hong, Seokyong;Yang, Daeki;Yu, Seungyeong;Jung, Sehyung;Kim, Minkook;oh, Seongjin;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.348-349
    • /
    • 2018
  • 본 논문은 DC Common 방식의 Hybrid PCS (Power Conditioning System)의 해외 실증사례에 대해 서술하고 있다. 본 시스템은 계통, PV(Photovoltaic), BESS (Battery Energy Storage System)로 구성되어 있으며 UAE의 Dubai에 60kW급 2기, 200kW급 1기를 실증한 사례를 설명한다. 각 구성품 들의 사양과 Destin Power사 Hybrid PCS를 소개하고 사양을 서술하였으며 실제 운영을 통하여 제품의 신뢰성을 검증하였다.

  • PDF

New Hybrid System with DC Common Method (DC Common 방식의 새로운 Hybrid 시스템)

  • Ha, Yong-Ho;Yang, Dae-ki;Yu, Seung-yeong;Hong, Seok-yong;Kim, Min-kook;Oh, Seong-jin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.219-220
    • /
    • 2019
  • 본 논문은 DC Common 방식의 새로운 Hybrid 시스템에 대해 제안하고 있다. 제안하는 시스템은 주간에 PV를 통해 배터리를 충전하고 야간에는 BESS(Battery Energy Storage System)로 발전하여 추가 배전용량의 증설 없이 신재생에너지의 발전량을 증가시킬 수 있는 시스템이다. 본 시스템은 계통 연계형 및 PV용 전력변환장치로 구성되며 SiC(Silicon Carbide) 소자를 사용하여 손실을 최소화 하였다. 따라서 각 구성품들의 사양과 Destinpower사가 개발한 알고리즘이 적용된 Hybrid 시스템을 소개한다.

  • PDF

The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water (콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석)

  • Baek, Nam-Choon;Jeong, Seon-Yeong;Yoon, Eung-Sang;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

An Efficient Hybrid Lighting Management System Implementation on Multi Protocol (다중 프로토콜 기반의 효율적인 하이브리드 조명관리 시스템 구현)

  • Hong, Sung-Il;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.550-558
    • /
    • 2013
  • In this paper, we propose an efficient hybrid lighting management system implementation on multiple protocol. The proposed hybrid lighting management system was implemented by configured as the data display part for management and control of lighting device and the data conversion-processing part the communication part of gateway. The data were designed the DB to enable to storage in real-time, and implemented able to manage by real time wireless remote control and schedule setting. The proposed an efficient hybrid lighting management system, it was possible the real-time monitoring and remote lighting control by peristalsis with smart devices and portable PC etc., and it could be obtained reduction effect of energy and electricity, communication cost.