• Title/Summary/Keyword: Hybrid Grid System.

Search Result 198, Processing Time 0.033 seconds

Analysis on the Limiting Method after Half Cycle of Hybrid Superconducting Fault Current Limiter using Simulation (시뮬레이션을 이용한 하이브리드 초전도 전류제한기의 반주기 후 한류 방식 분석)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Hyun, Ok-Bae;Seol, Kyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.63-64
    • /
    • 2008
  • The increase of fault current due to large demand has caused the capacity of power machines in power grid to increase. To protect the power system effectively from the large fault current, several superconducting fault current limiters have been proposed. however, in order to apply superconducting fault current limiters into power system, there are many problems such as cost, recovery, AC loss, and cryogenic. In order to solve these problems, hybrid superconducting fault current limiter(HSFCL) was proposed. However, HSFCL also has a problem that is protective coordination in distribution system with HFSCL. In this paper, HSFCL limiting after half cycle modeled and analyzed about protective coordination.

  • PDF

A Study on Multi-level Converter Based on Distribution Active Hybrid Solid State Transformer (멀티레벨 컨버터 기반 배전용 능동형 하이브리드 반도체 변압기에 대한 연구)

  • Yun, Chun-gi;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.84-86
    • /
    • 2018
  • Active hybrid solid state transformer(AHSST) is newly emerging as a device to maintan the power quality of power distribution. AHSST has a simple structure in which a power electronics device is connected in series to a conventional distribution transformer. The connected power electronics device maintains the constant voltage regardless of the primary grid voltage fluctuation through the secondary voltage control to improve the power quality. It also has a simple structure compare to conventional solid state transformer system and can achieve the same performance with fractionally-rated converter. This paper proposes an multi-level converter based on AHSST system that has a simpler control method and wider voltage control range than the conventional AHSST. The proposed system is verified by simulations.

  • PDF

Development of 3-D Flow Analysis Code Using Unstructured Grid System (II) - Code's Performance Evaluation - (비정렬격자계를 사용하는 3차원 유동해석코드 개발 (II) - 코드성능평가 -)

  • Kim, Jong-Tae;Kim, Jong-Eun;Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1057-1064
    • /
    • 2005
  • A conservative finite-volume numerical method using unstructured meshes, which is developed by the authors, is evaluated for its application to several 2-D benchmark problems using a variety of quadrilateral, triangular and hybrid meshes. The present pressure-based numerical method for unstructured mesh clearly demonstrates the same accuracy and robustness as that fur typical structured mesh.

A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

A basic study on protective relay testing using RTDS in power system applying SFCL (초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Kim, Jae-Ho;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

Optimized Hybrid Modulation Strategy for AC Bypass Transformerless Single-Phase Photovoltaic Inverters

  • Deng, Shuhao;Sun, Yao;Yang, Jian;Zhu, Qi;Su, Mei
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2129-2138
    • /
    • 2016
  • The full-bridge inverter, widely used for single-phase photovoltaic grid-connected applications, presents a leakage current issue. Therefore, an AC bypass branch is introduced to overcome this challenge. Nevertheless, existing modulation strategies entail drawbacks that should be addressed. One is the zero-crossing distortion (ZCD) of the AC current caused by neglecting the AC filter inductor voltage. Another is that the system cannot deliver reactive power because the AC bypass branch switches at the power frequency. To address these problems, this work proposes an optimized hybrid modulation strategy. To reduce ZCD, the phase angle of the inverter output voltage reference is shifted, thereby compensating for the neglected leading angle. To generate the reactive power, the interval of the negative power output is calculated using the power factor. In addition, the freewheeling switch is kept on when power is flowing into the grid and commutates at a high frequency when power is fed back to the DC side. In this manner, the dead-time insertion in the high-frequency switching area is minimized. Finally, the performances of the proposed modulation strategy and traditional strategies are compared on a universal prototype inverter. Experimental results validate the theoretical analysis.

Numerical Study of High Resolution Schemes for GH2/GO2 Rocket Combustor using Single Shear Coaxial Injector (단일 전단 동축 분사기를 가지는 GH2/GO2 로켓 연소기의 고해상도 수치해석)

  • Jeong, Seung-Min;Um, Jae-Ryeong;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.72-83
    • /
    • 2018
  • In this study, a series of CFD analyses were carried out for a hydrogen rocket combustor with a single shear coaxial injector. A hybrid RANS/LES approach was used for the turbulent combustion analysis with a two-dimensional axisymmetric configuration. Three reaction mechanisms, three spatial discretization methods, and three levels of grid resolution were compared to determine an appropriate CFD approach. The performance of the CFD prediction were investigated by comparing the wall heat flux with experimental data. Investigation of the flow field results provides an insight into the characteristics of the turbulent reacting flow of a rocket combustor with a shear coaxial injector.

Hybrid design method for air-core solenoid with axial homogeneity

  • Huang, Li;Lee, Sangjin;Choi, Sukjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.50-54
    • /
    • 2016
  • In this paper, a hybrid method is proposed to design an air-core superconducting solenoid system for 6 T axial uniform magnetic field using Niobium Titanium (NbTi) superconducting wire. In order to minimize the volume of conductor, the hybrid optimization method including a linear programming and a nonlinear programming was adopted. The feasible space of solenoid is divided by several grids and the magnetic field at target point is approximated by the sum of magnetic field generated by an ideal current loop at the center of each grid. Using the linear programming, a global optimal current distribution in the feasible space can be indicated by non-zero current grids. Furthermore the clusters of the non-zero current grids also give the information of probable solenoids in the feasible space, such as the number, the shape, and so on. Applying these probable solenoids as the initial model, the final practical configuration of solenoids with integer layers can be obtained by the nonlinear programming. The design result illustrates the efficiency and the flexibility of the hybrid method. And this method can also be used for the magnet design which is required the high homogeneity within several ppm (parts per million).

Analysis on Operation Characteristics of Hybrid Superconductor Fault Current Limiter(SFCL) with First Half Cycle Non-Limiting Operation (반주기 이후 하이브리드 초전도 전류제한기의 동작 특성 분석)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.239-244
    • /
    • 2011
  • Due to large demand, the increase of fault current has caused the capacity of power machines in power grid to increase. Among several countermeasures, the superconducting fault current limiter (SFCL) has been noticed as one of the promising countermeasures to solve these problems. However, in spite of excellent current limiting performances of the SFCL, the application of SFCL to power system has been delayed due to both the limited space for the SFCL's installation and its longer recovery time after the fault removal. In order to solve these problems, a hybrid type SFCL was developed. In this paper, we studied the operation characteristics of the hybrid SFCL with first half cycle non-limiting operation by modelling using PSCAD/EMTDC and experiment. It was shown through the simulation using PSCAD/EMTDC and the simulated experiment that the fault current limiting and the fast recovery operations of the hybrid SFCL with the first half cycle non-limiting operation were achieved.

Control Strategy for Hybrid Module with Energy Storage for Island Mode (에너지 저장 장치를 갖는 태양광 하이브리드 모듈의 제어 전략)

  • Choi, Bong-Yeon;Jang, Jin-Woo;Lee, Soon-Ryung;Kim, Young-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.477-478
    • /
    • 2013
  • This paper presents the control mehtod of a photovoltaic(PV) hybrid generation with energy storage system(ESS). To stabilize power control between PV generation system with ESS and local load, the proposed control method performs grid-connected and islanding operations. Through the simulation results the theoretical analysis of proposed method is verified.

  • PDF