• Title/Summary/Keyword: Humidity Control

Search Result 1,163, Processing Time 0.023 seconds

A Study on the Optical Characteristics According to the Lacquer Drying Conditions for the Conservation of Lacquerwares (칠기문화재 보존을 위한 옻칠 건조조건에 따른 광학적 특성 연구)

  • Hwang, In Sun;Park, Jung Hae;Kim, Soo-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.610-621
    • /
    • 2018
  • In conservation treatment lacquer has been used variously as a restoration material. However, dealing with Lacquer is very difficult as it dried in high humidity that can be harmful to the base materials. Also being natural varnish, dried lacquer layer is very different from the drying condition and the quality of the lacquer. These make difficult to predict the result of drying lacquer. In this study, using the humidity control machine, firstly, the main contents of the two different type of lacquer was experimented. And these lacquers was cured in various conditions. The duration time was checked until totally hardened. After that, obtained lacquer layers was analyzed to understand optical properties. Therefore, this study made a result about the relationship between characteristics of lacquer layer and the hardening condition. As a result, duration time of the Korean lacquer drying which has average 13.4% more urushiol than the Chinese lacquer is recorded a twice or triple decrease over it of the Chinese one. And, in all types of lacquer, the higher humidity makes the faster a pace of lacquer dried. In same lacquer, the shorter the duration time of drying lacquer is much darker and glossier. However, gloss deteriorated in saturated humidity. In humidity lower than RH 70%, lacquer is not hardened in 336 hours. When the layer totally cured through long period more than 30 days, the drying lacquer is appeared high brightness and almost transparent. Thus, in lower than RH 70%, it is hard to obtain durable layer.

Development of Neuro-Fuzzy System for Cold Storage Facility (저온저장고의 뉴로-퍼지 제어시스템 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.117-126
    • /
    • 2003
  • This study was conducted to develop precision control system fur cold storage facility that could offer safe storage environment for green grocery. For that reason of neuro-fuzzy control system with learning ability algorithm and single chip neuro-fuzzy micro controller was developed for cold storage facility. Dynamic characteristics and hunting of neuro-fuzzy control system were far superior to on-off and fuzzy control system. Dynamic characteristics of temperature were faster than on-off control system by 1,555 seconds(123% faster) and fuzzy control system by 460 seconds(36.4% faster). When system was arrived at steady state. hunting was ${\pm}$0.5$^{\circ}C$ in on-off control system, ${\pm}$0.4$^{\circ}C$ in fuzzy control system, and ${\pm}$0.3$^{\circ}C$ in neuro-fuzzy control system. Hunting of humidity and wind velocity was also controlled precisely by 70 to 72.5% and 1m/s For storage experiment with onion, characteristics of neuro-fuzzy control system were tested. Dynamic characteristics of neuro-fuzzy control system made cold storage facility conducted precooling ability and minimized hunting.

Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter (이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • This study was conducted to provide data necessary for reducing the condensation on greenhouse covering in winter season. The variation of VPD (Vapor Pressure Deficit) and condensation flux was analyzed in experimental tomato greenhouse. VPD values in experimental plastic greenhouse were greater than 0.2 kPa of disease prevention threshold, and lower than 0.5 kPa of threshold for dehumidification. The surface temperature of inside covering was slightly higher than the average temperature of outside and above curtain, and changed according to outside temperature. The humidity above curtain was nearly 100% and good condition for condensation. The humidity below curtain was 75~90% and comparatively stable condition for growing. The condensation flux value in experimental greenhouse corresponded with result of Seginer and Kantz (1986).

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

Changes in Evapotranspiration and Growth of Gold Mound, Japanese Spurge, and Ivy Plants According to Wind Speed (송악, 노랑조팝, 수호초의 풍속에 따른 증발산량 및 생육의 변화)

  • Park, Jihwan;Na, Haeyoung
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.72-76
    • /
    • 2021
  • The amount of evapotranspiration (water absorption) according to wind speed showed the same trend in gold mound (Spiraea × bumalda), Japanese spurge (Pachysandra terminalis), and ivy (Hedera japonica Tobler). All the three plants showed maximum water absorption at 4 m·s-1; water absorption tended to decrease as wind speed decreased. The control group without wind speed treatment had the most amount of water absorption compared with the groups that were subjected to wind exposure. However, the plant growth of all three plants increased to the maximum value when wind speeds were 2 and 1 m·s-1. When comparing the relationship among water absorption, air temperature, and relative humidity, the water absorption of plants tended to be low from May 20 to 26, when air temperature and relative humidity were the lowest. The results of this study will help establish an urban wall-planting system taking building wind into consideration. Further, this study may help in the selection of plant types for ecological parks in windy islands.

Design of Adaptive Neuro-Fuzzy Inference System Based Automatic Control System for Integrated Environment Management of Ubiquitous Plant Factory (유비쿼터스 식물공장의 통합환경관리를 위한 적응형 뉴로-퍼지 추론시 스템 기반의 자동제어시스템 설계)

  • Seo, Kwang-Kyu;Kim, Young-Shik;Park, Jong-Sup
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.169-175
    • /
    • 2011
  • The adaptive neuro-fuzzy inference system (ANFIS) based automatic control system framework was proposed for integrated environment management of ubiquitous plant factory which can collect information of crop cultivation environment and monitor it in real-time by using various environment sensors. Installed wireless sensor nodes, based on the sensor network, collect the growing condition's information such as temperature, humidity, $CO_2$, and the control system is to monitor the control devices by using ANFIS. The proposed automatic control system provides that users can control all equipments installed on the plant factory directly or remotely and the equipments can be controlled automatically when the measured values such as temperature, humidity, $CO_2$, and illuminance deviated from the decent criteria. In addition, the better quality of the agricultural products can be gained through the proposed automatic control system for plant factory.

Comparative analysis on environment control systems for glasshouses and plastic houses (유리온실과 플라스틱 온실의 환경조절시스템 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk;Yu, In-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.251-258
    • /
    • 2014
  • In order to set up the basic environmental control systems which the new concept greenhouses have to equip, greenhouse characteristics, environmental management and control systems in domestic glasshouses and plastic houses were investigated and analyzed comparatively. Survey results on the width, length, eaves height, and the number of spans etc. showed that glasshouses were bigger than plastic houses significantly. New concept greenhouses claim to be plastic houses, but it will be reasonable to follow the specifications of the glasshouse. Specifications to be applied to new concept greenhouses were proposed as follows; hot water heating systems, aluminum screens as the thermal curtain, evaporative cooling systems, roof vents on the ridge, circulation fans, $CO_2$ enrichment, hydroponic systems, and automatic irrigation control systems. Environmental measurement systems for the indoor and outdoor temperature, humidity, light, wind speed and indoor $CO_2$ concentration have to be fully equipped. The automatic control system has to be as a complex environmental control system, not a single item control system. Also, for stable dissemination, domestically producing complete greenhouse control system should be made as soon as possible.

Evolution of a Productive Bivoltine Hybrid of Silkworm Bombyx mori L.(SD7${\times}$SD12) with Shorter Larval Duration

  • Rao, P.Sudhakara;Basavaraja, H.K.;Kalpana, G.V.;Naik, V.Nishitha;Mahalingappa, K.C.;Pallavi, S.N.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2004
  • With an objective of evolving quantitatively and qualitatively superior bivolitine silkworm hybrid of Bombyxmori L. for tropics with shorter larval duration without compromising on productivity traits, a breeding programme was initiated at this institute during 1997 by utilizing breeding resource material from the institutes Germplasm collection. The breed SD7 is characterized with plain larvae spinning white oval cocoons and SD12 is characterized by sex-limited larval markings spinning white dumb-bell cocoons. After fixation, these breeds along with other newly evolved breeds were subjected for hybrid evaluation in the laboratory. Based on the hybrid studies, the hybrid SD7${\times}$SD12 was selected and evaluated for one year comprising three major sea- sons (6 trials) of tropics viz., Pre-monsoon (characterized by high temperature, low humidity and without any rain fall), Monsoon (characterized by moderate temperature, heavy rain fall with high humidity) and post-monsoon season (characterized by low temperature and low humidity with frequent rain fall) to know the fluctuations in the larval duration. The evaluation studies indicated that the hybrid is having shorter larval duration with productive merits. The hybrid SD7${\times}$SD12 recorded survival percent of 92.74, shell weight of 46.7 cg, shell ratio % of 24.0 and filament length of 1,200 meters with a shorter larval duration of 24 hrs; when compared to productive hybrid CSR2${\times}$CSR5(control). The breeding methodologies and hybrids usefulness for tropics were discussed.

Studies on Effects of Interior Plantscaping as Related to the Air Ions (공기이온으로 본 실내녹화 효과에 관한 연구)

  • Kim, Tae-Soon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.1-8
    • /
    • 2003
  • This study was carried out in order to investigate of effects of environmental conditions which influence negative ions development. Negative ions are nature' most powerful air-cleaning agents, are created by nature, and found at their most optimal levels where the air is most pure and healthy. Negative ions are regarded as one of the important factors which indicate the quality of the air. Therefore, the focus of this study was to clear relationship among negative ions development induced by plant cultivar and environmental conditions such as air temperature, light intensity and relative humidity. As the results of this study, it was found that negative ions development was promoted during the period with plants compared to the period without plants. In Particular, negative ions development was high under air temperature $20^{\circ}C$, relative humidity 90% and dark condition. Temperature and humidity factors on this experiment was strongly affected on negative ions development, but light intensity had almost slight effect. It was shown that these results can contribute to the application of environmental control techniques to negative ions. Among plant cultivar of Spathiphyllum spp. Mentha spicata, and Cupressu arizonica, Mentha spicata was higher negative ions than the other plants, and also the leaves were higher than the stems and roots. The effect of plants on the perception of the inte끼r air quality may, therefore, be one explanation of this results about negative ions. on the other hand, it seems that a green indoor environment might be an increase in general well-being due to the plants.

The Influence of Wearing Army Combat Uniform on the Thermal Responses in Heat Environment (서열환경하에서의 전투복착용이 체온조절에 미치는 영향)

  • Kim, Tae Gyou;Cho, Ho Hyun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.167-174
    • /
    • 2014
  • The physical properties of textile materials and thermal physiological responses of the human subjects were evaluated with 4 different types of the army combat uniforms including US, German, Korean and general uniforms for this study. 8 male adults were used as the human subjects and the tests were done in the environmental chamber that was $25{\pm}0.1^{\circ}C$ of temperature, $65{\pm}5%$ of relative humidity and below 0.3 m/sec of air velocity. The test protocol consisted the rest period for 20 min., the exercise period for 20 min., the rest period for 20 min., the exercise period under wind condition for 20 min., and the recovery period for 20 min. The human subjects walked with 4.5 km/hr for 10 min., ran 7.5 km/hr for 10 min. during the first exercise period and walked and ran with the same speeds under 3.5 m/sec of the air velocity that simulated outdoor condition during the second exercise period. The test results of the study were as follows; The wind condition affected the skin and microclimate temperature of the human subjects lower compared to without wind condition, but had insignificant effect on the humidity control. The low air permeability of Korean uniform caused blocking the elimination of the humidity from the body and the regulation of body temperature. However, Korean uniforms could be the excellent one with the designs considering the ventilation of the uniforms and the textile fabrics with better air permeability.