• 제목/요약/키워드: Human red blood cell

검색결과 90건 처리시간 0.025초

인공적혈구의 제조 및 이용 (Synthesis and Use of Artificial Red Cells)

  • 하종식;조응행;김구자
    • The Korean Journal of Physiology
    • /
    • 제24권1호
    • /
    • pp.15-26
    • /
    • 1990
  • Hemoglobin was purified from the outdated human red blood cells. Phospholipids were purified from egg yolk and stored in chloroform. The artificial red blood cells (hemosome) were prepared by encapsulation of hemoglobin with phospholipid mutilayer using rotary vacuum evaporator. The shape and size of hemosomes were measured by phase contrast microscope and image analyzer. The function of hemosomes was tested by measuring oxygen dissociation curve using blood gas analyzer. In order to test whether hemosomes are useful as blood substitute they were infused into rats of which one third of total blood were drawn. The results obtained are summarized at followings. 1) Hemosomes were spherical shape and their mean diameter was 0.7 um. 2) Oxygen dissociation curve of hemosomes showed the same figure as that of normal red blood cells. 3) All rats given 1/3 transfusion with hemosomes survived until sacrificed whereas three of four rats given 1/3 transfusion with saline died within 1 hour and the rest of them died within 24 hours.

  • PDF

인체적용시험을 통한 홍삼기반 'SSR'이 인체 피로도 감소 및 혈액성분 변화에 미치는 영향분석 (Analysis of the Effects of Red Ginseng Ingredient-based 'SSR' in Decreasing Fatigue and Inducing Changes in Blood Composition through a Clinical Trial)

  • 신경섭;이홍기;박선미
    • 한국식품영양학회지
    • /
    • 제34권2호
    • /
    • pp.196-206
    • /
    • 2021
  • The main purpose of this study was to examine the correlation between the consumption of red ginseng-based 'SSR' for 30 days and the reduction in human fatigue, blood component changes, and immune cell activity in 35 human subjects. 'SSR' is composed of zinc oxide, folic acid, and D-α-tocopherol with red ginseng as the main component. According to the protocol criteria of the study, 35 subjects who understood the purpose of the study and signed an informed consent form were selected. The fatigue survey was conducted through a questionnaire, and after taking 'SSR', a decreased tendency of physical, mental, and neurosensory fatigue was observed. In hematological analysis, no significant changes were observed in the levels of WBC, RBC, and hemoglobin; however, AST (SGOT) and ALT (SGPT) levels were statistically significantly decreased. In immunological analysis, it was observed that the proliferative effect of T cells (CD3+CD4+) was greater than that of NK cells (CD16+CD56+). The collected data were subjected to t-test analysis using the SPSS 25.0 statistical program. The result from this study proposes that 'SSR' can be used as a functional food material as it reduces human fatigue and enhances immune function.

Effect of Osmotic Stress on Human Red Cell Rheology: Cell Deformability, Aggregability and Blood Viscosity

  • Ku, Yun-Hee;Shin, Se-Hyun;Suh, Jang-Soo
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.7-12
    • /
    • 2006
  • The present study investigated the effects of the osmotic environment on the rheological properties of erythrocytes and their suspensions. In an iso-osmotic medium, erythrocytes forming a biconcave discocyte under resting conditions, exhibited high deformability. In a low-osmotic medium, the deformability of erythrocytes, which swelled and exhibited a spherical shape, significantly decreased at a high shear stress and the high-shear viscosity of the cell suspension was slightly higher than that of normal blood. Hyper-osmotic stress, however, which caused to form echinocytes, decreased cell deformability but exhibited smaller viscosity in low shear rates than iso-osmotic blood viscosity. These results showed a close relation with the aggregability measurements, in that hypertonic blood showed lower aggregability than the hypotonic and isotonic RBC suspensions. These findings indicate that the physicochemical environment has a strong influence on the rheological properties of the erythrocyte and its suspensions.

  • PDF

Hemorheological measurements in experimental animals: further consideration of cell size - pore size relations in filtrometry

  • Nemeth, Norbert;Baskurt, Oguz K.;Meiselman, Herbert J.;Furka, Istvan;Miko, Iren
    • Korea-Australia Rheology Journal
    • /
    • 제21권3호
    • /
    • pp.155-160
    • /
    • 2009
  • Micropore filtration of dilute red blood cell (RBC) suspensions is a widely known method for determining red blood cell deformability. Use of this method for cells from various laboratory animal species does require considering the effects of the cell size to pore size ratio and of suspension hematocrit. In general, previous animal studies have utilized 5% hematocrit suspensions and five micron pores, and thus conditions similar to human clinical laboratory practice. However, when used for repeated sampling from small laboratory animals or for parallel multiple samples from different sites in large laboratory animals, the volume of blood sampled and hence the hematocrit of the test suspension may be limited. Our results indicate that hematocrit levels yielding stable values of RBC pore transit time are pore size and species specific: three micron pores = $2{\sim}5%$ for dog and $3{\sim}5%$ for rat; five micron pores $3{\sim}5%$ for dog and $1{\sim}5%$ for rat. An analytical approach using a common expression for calculating transit time is useful for determining the sensitivity of this time to hematocrit alterations and hence to indicate hematocrit levels that may be problematic.

Diagnostic Power of Blood Parameters as Screening Markers in Gastric Cancer Patients

  • Pietrzyk, Lukasz;Plewa, Zbigniew;Denisow-Pietrzyk, Marta;Zebrowski, Remigiusz;Torres, Kamil
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4433-4437
    • /
    • 2016
  • Background: Gastric cancer (GC) is the fifth most common cancer worldwide. Since development is usually asymptomatic, it is generally diagnosed at an advanced stage. The value of screening in patients with nonspecific symptoms for GC is controversial. Aim: The study aimed to evaluate whether hematological parameters (platelet count (PC), mean platelet volume (MPV), MPV/PC ratio, red blood cell distribution width (RDW), neutrophil to lymphocyte ratio (NLR), and platelet to lymphocyte ratio (PLR)) are useful markers to differentiate between gastric cancer patients and healthy individuals. Materials and Methods: Sixty-one patients with gastric cancer and sixty-one healthy individuals were enrolled to the survey and retrospective analysis of selected blood parameters were performed. Results: The mean values of PC, MPV, RDW, NLR, and PLR were significantly higher in GC patients compared to the control group. No statistical differences were observed in MPV/PC ratios. Likewise, no significant statistical differences were revealed in values of blood parameters among TNM stage groups. The RDW showed the highest diagnostic specificity and sensitivity. Conclusions: Hematological parameters: PC, MPV, RDW, NLR, PLR have diagnostic power and can discriminate patients with gastric cancer from patients without cancer. Blood parameters compared with clinical symptoms might alert physicians and patients and lead to performancce of upper gastrointestinal endoscopy, the gold standard in gastric cancer screening and therebly increase the early detection of cancer.

Immunogenicity of Recombinant Human Erythropoietin: Clinical Cases, Causes and Assays

  • Heo, Tae-Hwe;Kim, Young-Kwon;Yang, Seung-Ju;Cho, Hyun-Jeong;Kim, Sung-Jo
    • 대한의생명과학회지
    • /
    • 제15권2호
    • /
    • pp.161-166
    • /
    • 2009
  • Human erythropoietin(EPO) is a glycoprotein that enhances red blood cell production by stimulating proliferation and differentiation of erythroid progenitor cells in the bone marrow. Patients with chronic kidney disease(CKD) suffer from anemia caused by reduced production of EPO in the kidney. Recombinant human EPO protein has been used successfully for the treatment of anemia associated with CKD. Recently, attention has been paid to the development of side effect of EPO, pure red cell aplasia(PRCA), in some patients with CKD. PRCA is a rare disorder of erythropoiesis that leads to a severe anemia due to an almost complete cessation of red blood cell production. EPO-related PRCA is caused by the production of EPO-neutralizing antibodies(Abs) that eliminate the biological activity of EPO as well as endogenous EPO in patients undergoing therapy. Since 1988, almost 200 cases worldwide have been reported with Ab-positive PRCA after receiving EPO therapeutics. The underlying mechanisms of the breaking of immune tolerance to self-EPO have been investigated. Modification of formulation, organic compounds of container closures, and route of administration has been suggested for the possible mechanism of increased immunogenicity of EPO. A number of assays have been used to detect Abs specific to EPO. These assays are generally grouped into two major categories: binding Ab assays and neutralizing Ab assays(bioassays). There are several types of binding Ab assays, including radioimmunoprecipitation assay, enzyme-linked immunosorbent assay, and the BIAcore biosensor assay. In vitro cell-based bioassays have been utilized for the detection of neutralizing Abs. Finally, the recent experience with anti-EPO Abs may have considerable implications for the future development and approval of EPO preparations. Also, considering that millions of patients are being treated with EPO, clinicians need to be aware of signs and consequences of this rare but severe clinical case.

  • PDF

운동선수들의 혈액분석을 통한 Etrythropoietin 간접도핑검사 (Blood Analysis for Indirect Doping Control of Erythropoietin in Sports)

  • 이정란;김소영;홍지연;김명수;최명자
    • 약학회지
    • /
    • 제47권6호
    • /
    • pp.422-431
    • /
    • 2003
  • The use of recombinant human erythropoietin (rhEPO), a stimulator of erythropoiesis, banned in sports because of the medical risk associated with thrombosis. Due to analytical difficulties to differentiate between natural human EPO (hEPO) and rhEPO, blood parameters of erythropoiesis such as contents of hemoglobin (cut-off value <17.5 g/d l for man, and < 16.0 g/dl for women), hematocrit and reticulocytes (cut-off value <2.0%) were measured to focus the misuse of rhEPO. We conducted anti-doping test for 122 blood samples of the World Cup athletes. The mean values of key parameters are as follows; 14.5$\pm$1.0 g/dl for hemoglobin, 41.7$\pm$2.8% for hematocrit, and 1.3$\pm$0.4% for reticulocyte. Blood sample was found to be stable up to 8 hours for the reticulocyte measurement. In addition, the soluble transferrin receptor and ferritin levels were measured by immunoassay methods using plasma samples (n=28) in which the mean value was 0.8$\pm$0.5 $\mu\textrm{g}$/$m\ell$ and 54.6$\pm$33.7 ng/$m\ell$, respectively. The results indicate that all samples tested were negative for the blood parameters of indirect anti-doping test for hEPO misuse. The statistical evaluation suggest that several other parameters such as red blood cell, mean corpuscular hemoglobin concentration, mean corpuscular volume, mean corpuscular hemoglobin and white blood cell could be considered as factors influencing hEPO function in addition to five parameters mentioned.

한국산 장류콩 종자 렉틴의 생화학적 특성 (Biochemical Properties of Seed Lectin from Korean Soybean Cultivars Developed for Soy Source)

  • 왕옥산;노광수
    • KSBB Journal
    • /
    • 제24권2호
    • /
    • pp.170-176
    • /
    • 2009
  • 한국산 장류콩 종자로부터 최종적으로 Sephadex G-100상에서 분리한 lectin의 분자량, 적혈구 응집력, 온도, 열 안정성, 및 pH의 생화학적 특성을 조사하였다. 분리된 lectin을 SDS-PAGE한 결과, 분자량이 32 kDa와 22 kDa인 2개의 band가 나타났으며, Native PAGE에 의해서 108 kDa의 tetramer임을 알 수 있었다. Lectin은 trypsin을 처리한 사람의 A, B, AB, O 혈액과 쥐 혈액에서 혈구응집 반응이 일어나지 않았으나 토끼에서는 응집 반응이 일어났으며, trypsin을 처리하지 않은 모든 혈액에서는 응집반응이 일어나지 않았다. 이 lectin은 최적온도가 20-$50^{\circ}C$이며, 10-$60^{\circ}C$ 에서 열 안정성을 보였다. 최적 pH는 7.2로서 6.2 이하와 8.0 이상에서는 활성이 상설되었다.

저압실 비행 훈련이 대한민국 공군 조종사의 혈액 성분에 미치는 영향 (Alterations in hematological parameters in Republic of Korea Air Force pilots during altitude chamber flight)

  • 김현수;전은령
    • 한국항공운항학회지
    • /
    • 제20권2호
    • /
    • pp.58-63
    • /
    • 2012
  • An altitude chamber, also known as a hypobaric chamber, is a device used during aerospace or high terrestrial altitude research or training to simulate the effects of high altitude on the human body. Although data from altitude chamber researches using experimental animals have been accumulated, studies in the humans exposed to hypobaric conditions are seldomly reported. Despite the importance of altitude chamber flight training in the field of aviation physiology, the hematological analysis of post-flight physiological changes has rarely been performed. The aims of the present study were to investigate the alterations in blood components during altitude chamber flight and to determine whether the differences between pre- and post-flight values are significant. Sixty experienced pilots in the Republic of Korea Air Force were enrolled in the altitude chamber flight training. Venous blood samples were obtained before and immediately after the flight. Compared with the pre-flight values($6.32{\times}10^3/mm^3$, $5.02{\times}10^6/mm^3$, 15.61 g/dL, respectively), white blood cell count, red blood cell count and hemoglobin level were significantly increased after the flight($6.77{\times}10^3/mm^3$, $5.44{\times}10^6/mm^3$, 16.26 g/dL; p=0.006, p=0.012, p<0.001, respectively). These alterations may be attributable to the exposure to hypobaric hypoxia, 100% oxygen supply for denitrogenation, considerable rise and fall in altitude and psychophysical stress due to these factors. In further studies, experimental groups and methods should be individualized to ensure objectivity and diversification. In addition, multiple time-frame analyses regarding the changing pattern of each blood component are also required to elucidate the physiological process for adapting to the high terrestrial altitude exposure.

Frequency of Red Blood Cell Antigens According to Parent Ethnicity in Korea Using Molecular Typing

  • Shin, Kyung-Hwa;Lee, Hyun-Ji;Kim, Hyung-Hoi;Hong, Yun Ji;Park, Kyoung Un;Kim, Min Ju;Kwon, Jeong-Ran;Choi, Young-Sil;Kim, Jun Nyun
    • Annals of Laboratory Medicine
    • /
    • 제38권6호
    • /
    • pp.599-603
    • /
    • 2018
  • Frequencies of red blood cell (RBC) blood group antigens differ by ethnicity. Since the number of immigrants is increasing in Korea, RBC antigens should be assessed in children/youths with parents of different ethnicities to ensure safe transfusions. We investigated the frequency of RBC antigens, except for ABO and RhD, in 382 children and youths with parents having Korean and non-Korean ethnicities. Subjects were divided into those with ethnically Korean parents (Korean group; N=252) and those with at least one parent of non-Korean ethnicity (non-Korean group; N=130). The 37 RBC antigens were genotyped using the ID CORE XT system (Progenika Biopharma-Grifols, Bizkaia, Spain). The frequencies of the Rh (E, C, e, $hr^S$, and $hr^B$), Duffy ($Fy^a$), MNS ($Mi^a$), and Cartwright ($Yt^b$) antigens differed significantly between the two groups. Eight and 11 subjects in the Korean and non-Korean groups, respectively, exhibited negative expression of high-frequency antigens, whereas 14 subjects in the non-Korean group showed positive expression of low-frequency antigens. The frequency of RBC antigens has altered alongside demographic changes in Korea and might lead to changes in distribution of RBC antibodies that cause acute or delayed hemolytic transfusion reaction.