• Title/Summary/Keyword: Human operator

Search Result 452, Processing Time 0.031 seconds

A Study on Regulatory Law for Management System of Combined Medical Device (결합 의료기기 관리제도의 규제관련 법률에 관한 연구)

  • Choi, Yong Jun;Choi, Mi Lim;Lee, Jeong Chan;Jung, Yong Gyu
    • Journal of Service Research and Studies
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • According to recent trends in technological advances and globalization, medical device industry may improve the constitution to meet worldwide medical equipment management system. Also it is holding a strand of mitigation to reach the level of international regulation. In addition, recent legislation tends are to stay limited ranges of industry regulations at least and take as open attitude for integration of new technologies combined medical devices. A greater environmental risk is not likely to work in medical technology, Combinded medical device is used as close to zero risk in most of the human body, which is classified as Class 1. Even medical device such as little or no risk in handling, it is possible to minimize the unnecessary administrative power and a waste of time to occur. For the medical device may be improving people's choices and access, medical equipment operator is expanding to include dealers, because this will be exalted to particular area of the business of the company. In this paper, we investigate the legal prerequisites for the establishment of a medical device. And propose improved regulations in topics in order to facilitate the repair and distribution markets for fair trade.

  • PDF

A Study on Decision of Minimum Required Channel Width Considering Ship Types by Fast Time Simulation (배속 시뮬레이션 기반의 선종별 최소 항로 폭에 관한 연구)

  • Kim, Hyun-suk;Lee, Yun-sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.309-316
    • /
    • 2020
  • Waterway design should prioritize appropriate channel width to ensure preferential safe passage for the arrival and departure of vessels. To calculate the minimum channel width required for safe passage a comprehensive review of several factors is required. These factors include vessel maneuverability, determined by vessel size, type and speed; environmental factors such as wind, tide, and wave action; human factors, including personal experience and operator judgment as well as marine traffic and navigation support facilities for decision making. However, the Korean channel width design standard is based only on vessel length, and requires improvement when compared with the standards of PIANC, USA, and Japan. This study aims to estimate the appropriate channel width required for one-way traffic in a straight channel, considering various vessel and environmental factors, using Fast Time Simulation (FTS). When the wind speed is 25 knots, with a current speed of 2 knots and a normal vessel speed of 10 knots FTS shows that a 150K GT Cruise Ship requires a minimum channel width of 0.67-0.91 the vessel length (L), whereas a 120K TEU Container Ship and a 300K DWT VLCC require 0.79-1.17 and 1.02-1.59, respectively. Such results can be used to calculate the minimum channel width required for safe passage as an improved Korean design standard.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

The Changes of Defibrillation Time Depending on the Manual External Defibrillator Device (제세동 시행도구에 따른 제세동 지연시간의 변화)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • Objectives: This study is to research delay time comparison for later defibrillation after hands off according to the changes in defibrillation electrodes. Study purpose: In defibrillation treatment that is the only way for cardiac arrest by arrhythmia, it is to find defibrillator device which can minimize late defibrillation delay time after important affect of hands off. Study object and method: After hands off according to the defibrillator device, we collected total 40 people for emergency medicine doctor, internal medicine doctor, general surgeon, nurse, emergency medical technician who are working at 2 CN, CS University hospitals in Gwangju Jeollanamdo district to find out hand off shock interval(HOSI). We then researched their general properties like occupation sector, experiences in clinic, gender, completion of AHA ACLS-P training and more. Then 40 participants continued ventricular fibrillation cardiac arrest simulation training (using human-model mannequin) designed by researcher and performed their roles as defibrillation operator. Each of participant used manual paddle and performed 4 times of defibrillation (150J) during 8 minutes of CPR and in 8day, the defibrillator devices were replaced from manual paddle to self-adhesive electrodes pads and 4 times of defibrillation (150J) under same simulation condition as manual paddle were performed. Study result: In comparison for delay time of later defibrillation after hands off of manual paddle and self adhesive electrodes pad, the self adhesive electrodes pad ($7.0{\pm}0.5sec$) seemed to reduce delay time of later defibrillation significantly (p<0.05) compared to manual paddle ($10.0{\pm}0.9sec$). The self adhesive electrodes pad, according to the general properties of participants, had no particular change in delay time after later defibrillation for the statistics (p>0.05) but the manual paddle had statistically significant differences for the occupation sector, experiences in clinic and gender (p<0.05). Conclusion: In defibrillation, the self adhesive electrodes pad($7.0{\pm}0.5sec$) showed short HOSI compared to manual paddle ($10.0{\pm}0.9sec$) significantly (p<0.05) and it applied identically for both existence and non-existence of ACLS-P training completion, experiences in clinic, gender and occupation sector. The manual paddle had also significant difference in experiences in clinic and occupation sector (p<0.05). which means the effect on HOSI according to the job mastery. Therefore, if the clinic experience is short or in case for the occupations without frequent defibrillation treatment has a danger of lowering success rate for the defibrillation using manual paddle. Therefore, it is true that using self adhesive electrodes pad for defibrillation electrodes when performing manual defibrillation in pre-hospital as well as in-hospital steps can generally minimize delay time of later defibrillation after hands off.

AUTOMATIC CABBAGE FEEDING, PILING, AND UNLOADING SYSTEM FOR TRACTOR IMPLEMENTED CHINESE CABBAGE HARVESTER

  • Song, K.S.;Hwang, H.;Hong, J.T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.489-497
    • /
    • 2000
  • Since Chinese cabbages weigh 3 to 5kgf and are big in size at the time of harvest, handling operations such as harvesting, loading and unloading including transportation require the highest labor demand among all other cultivation processes. Recently, though several cabbage harvesters were developed in Japan and Europe, those harvesters were not suitable for Chinese cabbages cultivated in Korea because of the size and shape. The cabbage harvester is almost meaningless without any proper cabbage piling and pallet unloading mechanism. Most harvesters developed so far adopted a sort of slide and free falling way in collecting cabbages into the pallet. Three or four labors are usually required for cleaning incoming cabbages and loading those in the pallet. Because of the required time for piling cabbages without severe damage and the required space capacity to carry empty and loaded pallets, harvesting speed should be adjusted in accordance with time required for consecutive operations. Up to now, any automatic or semi-automatic collecting device has not been developed in the world to pile cabbages on the layer one by one into the pallet in the ordered way with little damage and to unload pallet from the harvester continuously during the harvest process. To compromise system expenses and function, Semi-automatic cabbage piling and pallet unloading mechanism was devised and it required one labor. The foldable mesh pallet with a size of 1050mm x 1050mm x 1000mm and holding capacity of around 70 cabbages was utilized. The prototype for piling and unloading mechanism was composed of three parts such as feeding device, automatic piling device with retractable bellows, and pallet unloading device. Prior to developing the prototype, the geometric properties and the amount of the damage of the cabbage caused during the piling operation were investigated. Considering the height of the pallet, a series of cabbage carrying plates were mounted to the bracket chain to lift and to carry cabbages to the loading device. Indoor laboratory experiments showed that the cabbage carrying chain conveyor worked successfully. Considering the conveying speed 0.46m/sec of the pull up belt from the cabbages on the ground, the speed of cabbage carrying chain conveyor worked property in the range of 0.26m/sec to 0.36m/sec. The system allowed the operator to modify the position of cabbage slightly. Overall system worked successfully resulting into almost same capacity without severe damage to the cabbage as human did.

  • PDF

The Correlation Between Deltamethrin Exposure and Urinary 3-PBA Concentrations in Rats (Deltamethrin에 노출된 흰쥐의 뇨 중 3-PBA 검출 및 노출상관성)

  • Kim, Areumnuri;Chon, Kyongmi;Park, Kyung-Hun;Moon, Byeong-Chul;Ro, Jin-Ho;Paik, Min Kyoung
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.293-298
    • /
    • 2017
  • BACKGROUND: Pyrethroids (PYRs) are a widely used insecticide in agriculture and household area. In mammals, PYRs such as deltamethrin is metabolized to 3-phenoxybenzoic acid (3-PBA) in liver that is mainly excreted in urine. This study is designed to single exposure of deltamethrin to rats in a dose-dependent manner and identify the correlation between deltamethrin exposure and its metabolite (3-PBA) in urine. METHODS AND RESULTS: Exposure levels of deltamethrin were control (0 mg/kg bw), low (0.0705 mg/kg bw), medium (0.705 mg/kg bw) and high (7.05 mg/kg bw) dose. Low concentration was derived by ussing Korea predictive operator exposure model (KoPOEM). Dermal exposure persisted for 6 h, and urine specimens were collected for 24 h. The urine matrix was removed after a series of procedures and 3-PBA was analyzed by gas chromatography/mass spectrometry. CONCLUSION: There was a strong correlation ($R^2=0.83$) between the amount of oral exposure to delta me thrin and urinary levelof3-PBAexcreted. In dermal exposure groups of deltamethrin except high-dose, also there was a good correlation between urinary 3-PBA and deltamethrin exposure, but not stronger than in oral deltamethrin exposure groups. Based on these results, therefore, the amount of 3-PBA in urine can be used as a good monitoring indicator that reflexing the exposure level of deltamethrin to human body.

An Experimental Study on New Type Chip Brakeer(Part 1) (신形 칩折斷具에 관한 實驗的 硏究 (제1보))

  • 손명환;이호철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1121-1140
    • /
    • 1992
  • In metal cutting the shape of generated chip varies according to cutting conditions, characteristics of workpiece and geometry of cutting tool. The best surface roughness of machined workpiece is obtained when generating flow type contrinuous chip. If the generated chip is not broken, that is not only tangled workpiece and cutting tool, but also may give damage on the machined surface of workpiece or danger for a operator. The flow type continuous chip may bring the low productivity in high speed any heavy cutting, automatic machining process and non-human factory. There are two type of chip break process ; controlling cutting condition and using chip breaker. In present study we carried out the experiment on new type chip breaker compared with conventional type and proved the efficiency of a new type and showed the chip break condition to be applied in actual metal cutting. In the experiment SM 20 C as a workpiece material and WC as a tool material were used and cutting speed of 30-150m/min, feed of 0.071-0.210mm/rev and depth of cut of 1mm were applied as cutting condition. The results of the experiment are as follows : (1) The mechanism of chip curl can be explained more clearly by plastic flow of workpiece material and moment of shearing force. (2) The most effective radius of curled chip and flat distance from cutting edge is 2.0-2.5mm and 1.5mm in both types. (3) The effective inclination angle of chip break surface and side cutting edge angle are 30.deg.- 45.deg. and 20.deg. in conventional type, while the radius of arc surface, lower arc angle A, upper arc angle B and side cutting edge angle are 3mm, 20.deg.- 45.deg., 0.deg.- 45.deg. and 10.deg.- 20.deg. in new type. (4) The probability to be obtained 100% chip breaking ratio is much higher in new type than in conventional type.

The Implications of Increasing Safety and Environmental Standard for Ship Operators

  • Marsh, Captain A.G.
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.137-150
    • /
    • 1996
  • Safety is built in to the activities of the prudent ship operator. Ant investment made towards this end is likely to have a measurable payback in positive terms. That there must be an investment is inevitable, because the industry at large has let things slip too far too long. Those who have not allowed it to slip too far and who are the first to recognize that safety, far from costing money, in the long term actually preserves it, will be wieners. Too many seem to have lost sight of the fact that every one hundred pennies saved is a full one hundred pennies profit. Every hundred pennies of additional revenue contributes no more then fifteen pence to profit. Environmental protection is not so simple, nor so financially attractive. Man needs the minerals of the Earth as well as the products of the soil and sea survive. We(the human race) are still not in the position, politically or financially to manage the Earth's assets without causing damage. The evidence of our damage is evident in many different parts of the Glove and will in some cases haunt several generations still to come. We have learned a lot, and continue to learn, but despite the best intentions some Government needs for their people will be at the expense of people in another region for the foreseeable future. We sailors ply the seas with the raw materials of commerce as well as the finished and part finished goods. It does not always sit well to consider too deeply what effect the ship and the cargo it carries is having, or may have, on some communities, or on the sea through which sail. None my generation can hold up his head and claim to be without blame in the pollution of the seas. Times are changing though, and Governments are turning their attention more to the protection of our planet and its precious resources. This will not be without cost. The investment will have to be made not for our benefit, but for the benefit of generations yet to come, however the cost will have to be borne by society as a whole, not by the shipping community alone. The debate surrounding the choice between engineering our way to a better tomorrow, or adapting our working practices will continue. Each method has the same goal as its target and as long as we attain the goal does it really matter how we get there?

  • PDF

LiDAR Chip for Automated Geo-referencing of High-Resolution Satellite Imagery (라이다 칩을 이용한 고해상도 위성영상의 자동좌표등록)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.319-326
    • /
    • 2014
  • The accurate geo-referencing processes that apply ground control points is prerequisite for effective end use of HRSI (High-resolution satellite imagery). Since the conventional control point acquisition by human operator takes long time, demands for the automated matching to existing reference data has been increasing its popularity. Among many options of reference data, the airborne LiDAR (Light Detection And Ranging) data shows high potential due to its high spatial resolution and vertical accuracy. Additionally, it is in the form of 3-dimensional point cloud free from the relief displacement. Recently, a new matching method between LiDAR data and HRSI was proposed that is based on the image projection of whole LiDAR data into HRSI domain, however, importing and processing the large amount of LiDAR data considered as time-consuming. Therefore, we wmotivated to ere propose a local LiDAR chip generation for the HRSI geo-referencing. In the procedure, a LiDAR point cloud was rasterized into an ortho image with the digital elevation model. After then, we selected local areas, which of containing meaningful amount of edge information to create LiDAR chips of small data size. We tested the LiDAR chips for fully-automated geo-referencing with Kompsat-2 and Kompsat-3 data. Finally, the experimental results showed one-pixel level of mean accuracy.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF