• Title/Summary/Keyword: Human computer

Search Result 5,011, Processing Time 0.034 seconds

Analysis of the PTO Torque of a Transplanter by Planting Condition

  • Kim, Wan Soo;Chung, Sun Ok;Choi, Chang Hyun;Cho, Jong Seung;Choi, Dug Soon;Kim, Young Joo;Lee, Sang Dae;Hong, Soon Jung;Kim, Yong Joo;Koo, Seung Mo
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2016
  • Purpose: This study measured and analyzed the PTO (power take off) torque of a transplanter according to the planting conditions during field operation. Methods: A torque measurement system was constructed with torque sensors to measure the torque of a PTO shaft, a measurement device to acquire sensor signals, and a power controller to provide power for a laptop computer. The field operation was conducted at four planting distances (26, 35, 43, and 80 cm) and two planting depths using the transplanter on a field with similar soil conditions. One-way ANOVA with planting distance and Duncan's multiple range test at a significance level of 0.05 were used to analyze the PTO torque. The torque ratio was calculated based on the minimum torque using the average PTO torque measured under each planting condition. Results: The average torques on the PTO shaft for planting distances of 26, 35, 43, and 80 cm at a low planting depth were 11.05, 9.07, 7.04, and 3.75 Nm, respectively; the same for planting distances of 26, 35, 43, and 80 cm at a middle planting depth were 12.20, 9.86, 7.94, and 4.32 Nm, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at a low planting depth increased by 88, 142, and 195%, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at the middle planting depth increased by 84, 128, and 182%, respectively. Conclusions: PTO torque fluctuated by planting distance and depth. Moreover, the PTO torque increased for short planting distances. Therefore, farmers should determine the planting conditions of the transplanter by considering the load and durability of the machine. The results of this study provide useful information pertaining to the optimum PTO design of the transplanter considering the field load.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Visible Light Communication Based Wide Range Indoor Fine Particulate Matter Monitoring System (가시광통신 기반 광역 실내 초미세먼지 모니터링 시스템)

  • Shakil, Sejan Mohammad Abrar;An, Jinyoung;Han, Daehyun;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Fine particulate matter known as PM 2.5 refers to the atmospheric particulate matter that has a diameter less than 2.5 micrometer identified as dangerous element for human health and its concentration can provide us a clear picture about air dust concentration. Humans stay indoor almost 90% of their life time and also there is no official indoor dust concentration data, so our study is focused on measuring the indoor air quality. Indoor dust data monitoring is very important in hospital environments beside that other places can also be considered for monitoring like classrooms, cements factories, computer server rooms, petrochemical storage etc. In this paper, visible light communication system is proposed by Manchester encoding technique for electromagnetic interference (EMI)-free indoor dust monitoring. Important indoor environment information like dust concentration is transferred by visible light channel in wide range. An average voltage-tracking technique is utilized for robust light detection to eliminate ambient light and low-frequency noise. The incoming light is recognized by a photo diode and are simultaneously processed by a receiver micro-controller. We can monitor indoor air quality in real-time and can take necessary action according to the result.

Edge-Enhanced Error Diffusion Halftoning using Local mean and Spatial Activity (국부 평균과 공간 활성도를 이용한 에지 강조 오차확산법)

  • Kwak Nae-Joung;Kwon Dong-Jin;Kim Young-Gil;Ahn Jae-Hyeong
    • The KIPS Transactions:PartB
    • /
    • v.13B no.2 s.105
    • /
    • pp.77-82
    • /
    • 2006
  • Digital halftoning is the technique to obtain a bilevel-toned image from continuous-toned image. Among halftoning methods, the error diffusion method gives better subjective quality than other halftoning ones. But it also makes edges of objects blurred. To overcome the defect, we proposes the modified error diffusion to enhance the edges using the property that human vision perceives the local average luminance and doesn't perceive a little variation of the spatial variation. The proposed method computes a spatialactivity, which is the difference between a pixel luminance and the average of its $3{\times}3$ neighborhood pixels' Iuminance weighted according to the spatial positioning. The system also usesof edge enhancement (IEE), which is computed from the normalized spatial activitymultiplied by the average luminance. The IEE is added to the quantizer's input pixel and feeds into the halftoning quantizer. The quantizer produces the halftone image having the enhanced edge. The computer experimental results show that the proposed method produces clearer bilevel-toned images than conventional methodsand the edge of objects is preserved well. Also the performance of the preposed method is improved, compared with that of the conventional method by measuring the edge correlation and the local average accordance at some ranges of viewing distance.

Genetic polymorphisms of monoamine oxidase(MAO) B and serotonin transporter receptor(5-HTTR) influence variability in neurobehavioral symptoms by n-hexane exposur (n-Hexane 노출에 의한 신경행동학적 증상에 monoamine oxidase(B)와 serotonin transporter receptor 유전자다양성의 영향)

  • Kim, Ki-Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.2
    • /
    • pp.116-122
    • /
    • 2011
  • Human occupational exposure to n-hexane has been associated with neurobehavioral symptoms such as depression, irritablity, acute irritation symptom, concentration disturbance and fatigue. Effects of monoamine oxidase (MAO) B and serotonin transporter receptor (5-HTTR) polymorphisms on the neurobehavioral symptoms were investigated in 70 male workers from TV and computer monitor manufacturing plants exposed to n-hexane. Neurobehavioral symptoms were assessed through a self-reported questionnaire and ambient level of n-hexane was measured by NIOSH method. Blood and urine were collected from each workers to determine the MAO(B), 5-HTTR and urinary 2,5-hexanedione(2,5-HD). The mean concentration of volatile n-hexane was $18.8{\pm}28.8ppm$ and that of urinary 2,5-HD was $1.07{\pm}1.47mg/g$ creatinine. Statistically significant associations with sexual disturbance were age and smoking. The frequencies of MAO(B) AA, AG and GG were 18.6%, 45.7% and 35.7%, respectively, and the frequencies of 5-HTTR ll, ls and ss genotype were 82.9%, 15.7% and 1.4%, respectively. MAO (B) gene polymorphisms had susceptibility to the neurobehavioral symptoms such as fatigue, concentration disturbance, irritability and acute irritation symptom and 5-HTTR gene polymorphism had susceptibility to the sleep disturbance and acute irritation symptom. On multiple logistic regression analysis for the neurobehavioral symptoms, memory disturbance was significantly associated with smoking(OR=6.752, 95% CI=37.46) and drinking(OR=4.033, 95% CI=1.252-12.98), emotional lability was MAO(B) genotype(OR=0.412, 95% CI=0.170-0.996), fatigue (OR=1.011, 95% CI=1.000-1.021) and acute irritation(OR=0.990, 95% CI=0.981-1.000) were working duration and sexual disturbance were significantly associated with age(OR=1.208, 95% CI=1.042-1.399), ambient n-hexane(OR=1.077, 95% CI=1.005-1.154) and 2,5-HD(OR=0.186, 95% CI=0.041-0.841). This finding implies that the MAO (B) and 5-HTTR polymorphisms may affect susceptibility for specific neurobehavioral symptoms associated with n-hexane exposure in workers.

The Protective Effects of IGF-1 on Different Subpopulations of DRG Neurons with Neurotoxicity Induced by gp120 and Dideoxycytidine In Vitro

  • Lu, Lin;Dong, Haixia;Liu, Guixiang;Yuan, Bin;Li, Yizhao;Liu, Huaxiang
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.532-539
    • /
    • 2014
  • Peripheral neuropathy induced by human immunodeficiency virus (HIV) infection and antiretroviral therapy is not only difficult to distinguish in clinical practice, but also difficult to relieve the pain symptoms by analgesics because of the severity of the disease at the later stage. Hence, to explore the mechanisms of HIV-related neuropathy and find new therapeutic options are particularly important for relieving neuropathic pain symptoms of the patients. In the present study, primary cultured embryonic rat dorsal root ganglion (DRG) neurons were used to determine the neurotoxic effects of HIV-gp120 protein and/or antiretroviral drug dideoxycytidine (ddC) and the therapeutic actions of insulin-like growth factor-1 (IGF-1) on gp120- or ddC-induced neurotoxicity. DRG neurons were exposed to gp120 (500 pmol/L), ddC ($50{\mu}mol/L$), gp120 (500 pmol/L) plus ddC ($50{\mu}mol/L$), gp120 (500 pmol/L) plus IGF-1 (20 nmol/L), ddC ($50{\mu}mol/L$) plus IGF-1 (20 nmol/L), gp120 (500 pmol/L) plus ddC ($50{\mu}mol/L$) plus IGF-1 (20 nmol/L), respectively, for 72 hours. The results showed that gp120 and/or ddC caused neurotoxicity of primary cultured DRG neurons. Interestingly, the severity of neurotoxicity induced by gp120 and ddC was different in different subpopulation of DRG neurons. gp120 mainly affected large diameter DRG neurons (> $25{\mu}m$), whereas ddC mainly affected small diameter DRG neurons (${\leq}25{\mu}m$). IGF-1 could reverse the neurotoxicity induced by gp120 and/or ddC on small, but not large, DRG neurons. These data provide new insights in elucidating the pathogenesis of HIV infection- or antiretroviral therapy-related peripheral neuropathy and facilitating the development of novel treatment strategies.

ADHD Simple Examination Using an OSGi Base USB Terminal System (OSGi 기반 USB 단말기 시스템을 이용한 ADHD 간편검사)

  • Han, Sang-Seok;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.664-673
    • /
    • 2008
  • Recently, the ubiquitous is handled by maximum topic. New knowledge information and ubiquitous computing evolution have promoted new paradigm transfer and grand change. Also, need technology as powerful engineering approached fairly system and educational guidance side examination necessarily to overcome u-Learning base situation and studying obstacle situations. This treatise embodied handiness examination about attention shortage and excess obstacle (Attention Deficit Hyperactivity Disorder, low ADHD) who must solve so as to be square and level being increase trend in primary school using USB (Universal Serial Bus) terminal system that allow fetters to OSGi (Open Service Gateway Initiative). That OSGi base USB terminal system is easy preservation of information, safety of network, cost-cutting and maintenance by various ubiquitous system that server that load many USB terminals and OSGi uses an USB bus of high speed and construct network, there is advantage of concentration elevation and so on of week and ADHD handled in this treatise because early diagnosis and treatment are serious. The confirmed system application that can supplement paper and pens examination's shortcoming and could solve examination's problem which use computer, and help in student guidance through ADHD simpleexamination who utilize OSGi base USB terminal system. Is available by game system that system for human nature examination or intelligence test and general exam explaining and level studying, order style question investigation program, studying system for disabled person, majority that enforce in public in school this study finding does together.

Implementation of a DB-Based Virtual File System for Lightweight IoT Clouds (경량 사물 인터넷 클라우드를 위한 DB 기반 가상 파일 시스템 구현)

  • Lee, Hyung-Bong;Kwon, Ki-Hyeon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.10
    • /
    • pp.311-322
    • /
    • 2014
  • IoT(Internet of Things) is a concept of connected internet pursuing direct access to devices or sensors in fused environment of personal, industrial and public area. In IoT environment, it is possible to access realtime data, and the data format and topology of devices are diverse. Also, there are bidirectional communications between users and devices to control actuators in IoT. In this point, IoT is different from the conventional internet in which data are produced by human desktops and gathered in server systems by way of one-sided simple internet communications. For the cloud or portal service of IoT, there should be a file management framework supporting systematic naming service and unified data access interface encompassing the variety of IoT things. This paper implements a DB-based virtual file system maintaining attributes of IoT things in a UNIX-styled file system view. Users who logged in the virtual shell are able to explore IoT things by navigating the virtual file system, and able to access IoT things directly via UNIX-styled file I O APIs. The implemented virtual file system is lightweight and flexible because it maintains only directory structure and descriptors for the distributed IoT things. The result of a test for the virtual shell primitives such as mkdir() or chdir() shows the smooth functionality of the virtual file system, Also, the exploring performance of the file system is better than that of Window file system in case of adopting a simple directory cache mechanism.

Bus-only Lane and Traveling Vehicle's License Plate Number Recognition for Realizing V2I in C-ITS Environments (C-ITS 환경에서 V2I 실현을 위한 버스 전용 차선 및 주행 차량 번호판 인식)

  • Im, Changjae;Kim, Daewon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.87-104
    • /
    • 2015
  • Currently the IoT (Internet of Things) environments and related technologies are being developed rapidly through the networks for connecting many intelligent objects. The IoT is providing artificial intelligent services combined with context recognition based knowledge and communication methods between human and objects and objects to objects. With the help of IoT technology, many research works are being developed using the C-ITS (Cooperative Intelligent Transport System) which uses road infrastructure and traveling vehicles as traffic control infrastructures and resources for improving and increasing driver's convenience and safety through two way communication such as bus-only lane and license plate recognition and road accidents, works ahead reports, which are eventually for advancing traffic effectiveness. In this paper, a system for deciding whether the traveling vehicle is possible or not to drive on bus-only lane in highway is researched using the lane and number plate recognition on the road in C-ITS traffic infrastructure environments. The number plates of vehicles on the straight ahead and sides are identified after the location of bus-only lane is discovered through the lane recognition method. Research results and experimental outcomes are presented which are supposed to be used by traffic management infrastructure and controlling system in future.

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF