• Title/Summary/Keyword: Human body fluid

Search Result 125, Processing Time 0.025 seconds

Fundamental Design of Cyclone Collector for Oil Mist (오일미스트용 사이클론 집진기에 관한 기초 설계 -오일미스트 및 슬러지 입자 융합연구-)

  • Jang, Sung-Cheol;Ahn, Hwi-Woong;Lee, Chan-Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.223-227
    • /
    • 2013
  • Dust collecting performance of cyclone collector for oil mist was alalyzed in the study. The purposes of using cutting fluid during cutting have been colling, lubricating, chip washing and anti-corroding. However, the present manufactaring industry restricts the use of cutting fluid because cutting fluid confains poisonous substances which are harmful to the human body. Also, the optimum design oil-mist collector. The new oil mist collector was designed. In the near future, this device must be tested in the real machining center and CNC machine. Cutting using oil-mist showed better cutting characteristics than dry, air and fluid cutting with respect to by cutting force, tool wear and surface roughness. The model(A, B Type cyclone) of the set of fixture and alveolus are made by using a CAE software. Finally, we have obtained a model A Type solution by using orthogonal array. Therefore, it could be confirmed that as the model-A was increased and model-B was decreased, cut diameter was decreased.

DEVELOPMENT OF A MODIFIED $k-{\varepsilon}$ TURBULENCE MODEL FOR VISCO-ELASTIC FLUID AND ITS APPLICATION TO HEMODYNAMICS (점탄성 유체의 난류 해석을 위한 수정된 $k-{\varepsilon}$ 난류모델 개발 및 혈류역학에의 적용)

  • Ro, K.C.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2010
  • This article describes the numerical investigation of turbulent blood flow in the stenosed artery bifurcation under periodic acceleration of the human body. Numerical analyses for turbulent blood flow were performed with different magnitude of periodic accelerations using a modified turbulence model which was considering drag reduction of non-Newtonian fluid. The blood was considered to be a non-Newtonian fluid which was based on the power-law viscosity. In order to validate the modified $k-{\varepsilon}$ model, numerical simulations were compared with the standard $k-{\varepsilon}$ model and the Malin's low Reynolds number turbulence model for power-law fluid. As results, the modified $k-{\varepsilon}$ model represents intermediate characteristics between laminar and standard $k-{\varepsilon}$ model, and the modified $k-{\varepsilon}$ model showed good agreements with Malin's verified power law model. Moreover, the computing time and computer resource of the modified $k-{\varepsilon}$ model were reduced about one third than low Reynolds number model including Malin's model.

Cutting Characteristics of Dry Turning Using Compressed Air (압축공기를 이용한 건식 선삭가공의 절삭특성)

  • Song Chun-Sam;Kim Joo-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2005
  • The purposes of using cutting fluid during cutting have been cooling, lubricating, chip washing, and anti-corroding. However, the present manufacturing industry restricts the use of cutting fluid because cutting fluid contains poisonous substances which are harmful to the human body. Therefore dry cutting becomes an unavoidable assignment and a lot of researches have studied cutting methods without using cutting fluid. Because dry turning is a continuous work, tools life is reduced by continuous heat generation and surface gets rough due to reduced lubrication, so it is important to consider these situations. In this paper, the way of selecting the optimal machining condition by the minimum number of experiments and the effectiveness of using compressed air in high hardness materials through Taguchi method have been found. Dry cutting using compressed air showed better cutting characteristics than normal dry cutting with respect to by cutting force, tool wear, and surface roughness. Also, the optimal machining condition f3r dry cutting using compressed air could be selected through Taguchi method.

Expression of Tight Junction Molecule In The Human Serum-Induced Aggregation of Human Abdominal Adipose-Derived Stem Cells In Vitro

  • Yoon, A Young;Yun, Sujin;Yang, HyeJin;Lim, Yoon Hwa;Kim, Haekwon
    • Development and Reproduction
    • /
    • v.18 no.4
    • /
    • pp.213-224
    • /
    • 2014
  • Previously we have shown that human abdominal adipose derived-stem cells (ADSCs) could aggregate during the high-density culture in the presence of human serum (HS). In the present study, we observed that human cord blood serum (CBS) and follicular fluid (HFF) also induced aggregation. Similarly, porcine serum could induce aggregation whereas bovine and sheep sera induced little aggregation. qRT-PCR analyses demonstrated that, compared to FBS-cultured ADSCs, HS-cultured cells exhibited higher level of mRNA expression of CLDN3, -6, -7, -15, and -16 genes among the tight junction proteins. ADSCs examined at the time of aggregation by culture with HS, BSA, HFF, CBS, or porcine serum showed significantly higher level of mRNA expression of JAM2 among JAM family members. In contrast, cells cultured in FBS, bovine serum or sheep serum, showed lower level of JAM2 expression. Immunocytochemical analyses demonstrated that the aggregates of HS-cultured cells (HS-Agg) showed intense staining against the anti-JAM2 antibody whereas neither non-aggregated cells (HS-Ex) nor FBS-cultured cells exhibited weak staining. Western blot results showed that HS-Agg expressed JAM2 protein more prominently than HS-Ex and FBS-cultured cells, both of latter reveled weaker intensity. These results suggest that the aggregation property of ADSCs during high-density culture would be dependent on the specific components of serum, and that JAM2 molecule could play a role in the animal sera-induced aggregation in vitro.

Effects of Elastic Blood Vessel Motions on the Wall Shear Stresses for Pulsatile Flow of a Newtonian Fluid and Blood (뉴턴유체와 혈액의 맥동유동시 탄성혈관의 운동이 벽면전단응력분포에 미치는 영향)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Gil-Moon;Suh, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.318-323
    • /
    • 2001
  • Characteristics of the pulsatile flow in a 3-dimensional elastic blood vessel are investigated to understand the blood flow phenomena in the human body arteries. In this study, a model for the elastic blood vessel is proposed. The finite volume prediction is used to analyse the pulsatile flow in the elastic blood vessel. Variations of the pressure, velocity and wall shear stress of the pulsatile flow in the elastic blood vessel are obtained. The magnitudes of the velocity waveforms in the elastic blood vessel model are larger than those in the rigid blood vessel model. The wall shear stresses on the elastic vessel vary with the blood vessel motions. Amplitude indices of the wall shear stress for blood in the elastic blood vessel are $4\sim5$ times larger than those of the Newtonian fluid. As the phase angle increased, point of the phase angle is are moved forward and the wall shear stresses are increased for blood and the Newtonian fluid.

  • PDF

FSI simulation of pulsatile flow in the blood vessel (혈관내 맥동유동의 FSI 모사)

  • Kim, Yun-Gi;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1484-1486
    • /
    • 2008
  • Characteristics of pulsatile flow in 3-dimensional elastic vessel wall should be investigated in order to understand the physiological blood flow in human body. In this study, the modelling of the physiological blood flow in the elastic blood vessel is proposed. Variation of the pressure and the velocity wavefroms are obtained using the FSI method

  • PDF

Drug localization by magnetic fluids of $Cu_xFe_{1-x}OFe_2O_3$

  • Park, S. I.;Y. Q. Huang;Kim, C. O.;Kim, J. H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.88-89
    • /
    • 2002
  • Studies on drug delivery using nano-size particles of magnetic fluid and hyperthermia have been performed by some researchers [1] because interests in human health increased according to industry development. However, there are few studies on systems which can accurately control delivery of the magnetic fluids to a diseased part of body [2]. In this study, Cu-added magnetic ferrofluid was prepared and the external magnetic field system was designed for drug localization.

  • PDF

Study of Blood Characteristics in Stenosed Artery under Human Body Rotation by Using FSI Method (FSI 기법을 적용한 인체 회전 시 협착 혈관에서의 혈류 특성)

  • Cho, Seong Wook;Kim, Seungwook;Ro, Kyoung Chul;Ryou, Hong Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.449-457
    • /
    • 2013
  • In this study, we performed a numerical analysis to investigate the effect of rotation on the blood flow and arterial wall behavior by using the FSI (fluid-structure interaction) technique. The geometry of the artery included 50% stenosis at the center. To simulate the rotational effect, 2-6 rps of axial velocity was applied to the arterial model. A spiral wave and asymmetric flow occurred due to the stenosis and axial rotation both in the rigid body model and in the FSI model. However, the arterial wall motion caused periodic and transient blood flow changes in the FSI model. The FRZ (fluid recirculation zone) decreased in the FSI model, which is a known predictor for the formation and vulnerability of plaque. Therefore, it is observed that arterial wall motion also influences the generation of the FRZ.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Numerical Study on Human Thermal Comfort in a Passenger Train (기차 승객의 온열 쾌적성에 관한 수치해석)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.82-89
    • /
    • 2016
  • This paper presents computational fluid dynamics (CFD) analysis on passenger thermal comfort in a train. Human thermal comfort in vehicles depends mainly on air temperature, mean radiant temperature, air velocity, humidity, and direct solar flux, as well as the level of activity and thermal properties of clothing and seat. The velocity and temperature distribution in a train with and without passengers are reported. The thermal comfort in a passenger train are also presented based on PMV and PPD indices with 16 segments of the human body.