• Title/Summary/Keyword: Hts Transformer

Search Result 123, Processing Time 0.036 seconds

Estimation Methodology of Future Market Size for HTS Power Devices (초전도 전력기기 미래 시장규모 예측방법론)

  • Kim, Jong-Yul;Lee, Seung-Ryul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1535-1542
    • /
    • 2007
  • HTS (High Temperature Superconducting) Power devices has the several useful characteristics from the technical and economical viewpoint. Possible application to the utility industry have been widely discussed in various research projects. For the successful introduction of HTS power devices into power system, establishing a proper R&D and marketing strategies through estimating the future market size are necessary. However, quantitative estimates of how well HTS power devices will serve their markets have been lacking. In this paper, we propose a estimation methodology of future market size for HTS power divices such as cable, transformer, generator, and motor, and also evaluate the future international and domestic market size by using proposed methodology.

V-t and Barrier Characteristics for HTS Transformer Insulation Design (고온초전도변압기 절연설계를 위한 격벽효과와 수명특성)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kim, Young-Seok;Kwak, Dong-Soon;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.61-64
    • /
    • 2003
  • In the response to an increasing demand for electrical energy, much effort aimed to develop and commercialise HTS power equipments is going on around the world. For the development, it is necessary to establish the dielectric technology in $LN_2$. Hence many types of dielectric tests should be carried out to understand the dielectric phenomena at cryogenic temperature and to gather various dielectric data. Among the many types dielectric tests, the barrier effect were conducted with the simulated electrode after analysing the insulating configuration of the pancake coil type HTS transformer. The influence of a barrier on the dielectric strength was measured according to the size and the position of the barrier. It was shown that the effectiveness, the ratio of the breakdown voltage in presence of barrier to the voltage without barrier, is highest when the barrier is placed at the needle electrode side. And the barrier effect was not depend on the electrode array. The life time to breakdown with decreasing the applied voltage was increased remarkably having wide error band but the shape parameter in Weibull distribution was almost constant.

  • PDF

Sheld of AC magnetic filed using High Temperature Superconductor (고온초전도체에 의한 교류자장 차폐효과)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Hahn, Song-Yop;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.932-934
    • /
    • 2002
  • In this paper, we proposed a method to shield perpendicular magnetic fields in high Tc superconductor(HTS) tape of a shell-type HTS transformer with double pancake windings. A diamagnetism of characteristics of superconductor is used to shield magnetic field. For a shielding experiment, a proper shielding model is chosen, and several kinds of HTS are used such as a monofilament HTS tape, two kinds of multifilament HTS tapes and YBCO film disk. The effect of shielding for the perpendicular magnetic field is measured with HTSs for shielding and their utility for shielding is proved.

  • PDF

Fabrication of long length Bi-2223/Ag HTS tape (Bi-2223/Ag 고온초전도 장선재의 제조)

  • Kim, Sang-Cheol;Lee, Dong-Hoon;Ha, Dong-Woo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.69-72
    • /
    • 2004
  • In order to use HTS tape on electric power applications, such as cable, motor, transformer, fault current limiter, a long length of HTS tape with a good uniformity of critical current is inevitable. The longer length of HTS tape, the wider in the range of application and the lower cost of HTS tape. In this study three long length Bi-2223/Ag tapes(268m, 253m and 187m) were fabricated. Critical current uniformity along the length was greatly improved through the optimization of cold deformation and thermo-mechanical process. Average critical current of the tapes was 63.2 A, 54.6 A and 64.2 A, respectively Critical tensile strength and critical bending radius (77 K, 5 % Ic degradation) was 135 MPa and 56 m, respectively.

  • PDF

Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry (적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정)

  • Park, Myung-Jin;Lim, Hyoung-Woo;Lee, Kwang-Youn;Cha, Guee-Soo;Lee, Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

A study on the SMES component modeling using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 SMES Component modeling에 관한 연구)

  • Kim, Jin-Gun;Kim, Jae-Ho;Jung, Hee-Yeol;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1998-1999
    • /
    • 2007
  • Before applying the HTS(High Temperature Superconductor) power devices to a real utility network, system analysis should be carried out by some simulation tools. PSCAD/EMTDC simulation tool is one of the most popularized useful analysis tools for electrical power system. Unfortunately the model component for HTS coil is not provided in PSCAD/EMTDC simulation tool. In this paper, EMTDC model component for HTS coil has been developed considering real characteristics of HTS coil like critical current, temperature and magnetic field. The developed model component of HTS coil could be used for power system application. Using the developed model component for HTS coil, we can easily do the simulation of HTS power devices application test in utility with the various inductance, quench current, inner magnetic field, and temperature values, for instances; SMES(Superconducting Magnetic Energy Storage) system, superconducting motor, transformer, and FCL(Fault Current Limiter)

  • PDF

A Study on Insulating Design and Test of Mini-Model windings for a 22.9 kV Class HTS Transformer Reducing AC Loss (저손실 22.9 kV급 고온초전도 변압기를 위한 미니 모델 권선의 절연 설계 및 시험 연구)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van Dung;Kwag, Dong-Sun;Lee, Chang-Hwa;Kim, Hea-Jong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.94-99
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9 kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

  • PDF

Current Distribution in The Winding of a Superconducting Transformer (초전도 변압기 권선의 전류분류)

  • Lee Dong-Kun;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.851-853
    • /
    • 2004
  • This paper deals with current distribution analysis of the windings of a superconducting transformer with BSCCO-2223 High Tc Superconducting (HTS) tapes. Current distribution of HTS windings wound in parallel is analyzed by electromagnetic field analysis of finite element method and verified by experiments. For the sake of uniform current distribution, windings must be transposed so to make the impedances of each strands same. The parallel HTS tapes were transposed between the pancakes via non-superconducting joints because it is hard to make transpositions inside the pancake windings. In order to measure current distribution, test windings are fabricated and experimented for both transposed and non-transposed windings. We compared test results with calculated ones.

  • PDF

Characteristics of Surface flashover in LN2 (액체질소 중에서의 연면방전 특성)

  • 정종만;백승명;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.70-76
    • /
    • 2003
  • For the development of superconducting power apparatus, it is necessary to establish the dielectric technology in coolant like L$N_2$. Therefore in this paper we conducted experiment of surface flashover that could occur in the windings of HTS transformer which will be developed in the pancake coil type. First, we distinguished two types of surface flashover by electrode alignment, such as parallel and vertical, and then compared with each characteristics of surface flashover. The flashover voltage was more affected by thickness of spacer than by surface length when the thickness of spacer is over 1 mm. And the surface flashover with metallic particle attached on the spacer was tested, it was affected by the particle position. The more close to the electrodes, the worse the characteristics. Also the experiment was conducted when the electrode was immersed in liquid nitrogen(L$N_2$) partially. The surface flashover characteristics of spacer was, when immersed partially in 50%, rapidly decreased.