• Title/Summary/Keyword: Hreat rate

Search Result 2, Processing Time 0.019 seconds

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

Prediction of VO2max Using Submaximal PACER in Obese Middle School Boys (최대하 PACER 검사를 통한 비만 남자 중학생의 VO2max 추정)

  • Kim, Do-Youn;Kim, Won-Hyun
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.371-380
    • /
    • 2013
  • The purpose of this study was to develop the equation of $\dot{V}O_{2max}$ by $sub_{max}imal$ PACER method for obese middle school boys. For this, $_{max}$imal test using Bruce protocol in lab was performed and then PACER $_{max}imal$ test with portable $\dot{V}O_{2max}$ equipment. To decide the level of submaximal test, during PACER with portable equipment, we found the section in which target hreat rate(over 75%$HR_{max}$) and then per section(75%,80%,85%,90%,95%) metabolic responses were recorded, with which we analyzed multiple regression by stepwise method. Model 1(at 90%$HR_{max}$): $\dot{V}O_{2max}$(ml/kg/min) = 142.721-0.275(repetition)-0.48(HR)+0.177(weight)-1.536(age)[%error 3.90ml/kg/min; performance until 2 stage(13 repetition)]. Model 2(at 95%$HR_{max}$): $\dot{V}O_{2max}$(ml/kg/min) = 182.851-0.103(repetition)-0.744(HR)+0.186(weight)-0.324(age)[%error 4.51ml/kg/min; performance until 3 stage(25 repetitions)]. estimated $\dot{V}O_{2max}$ from Model 1 was different about $3.25{\pm}6.32ml/kg/min$(%error=6.84%), otherwise model 2 was $3.16{\pm}4.54ml/kg/min$(%error=5.75%). considering %HRmax, as the submaximal test model 1 might be fit more than model 2 for obese middle school boys.