• 제목/요약/키워드: Hounsfield Unit(HU)

검색결과 91건 처리시간 0.031초

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • 대한수의학회지
    • /
    • 제47권2호
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

고급 모델링 반복 재구성법(ADMIRE)이 CT 영상의 화질에 미 치는 영향: 흉부 비조영 CT에서 (The Effect of Advanced Modeling Iterative Reconstruction(ADMIRE) on the Quality of CT Images : Non-contrast CT in Chest)

  • 이상헌;이효영
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.159-168
    • /
    • 2019
  • 흉부 CT스캔에서 공기, 지방, 근육, Background의 HU, 잡음 그리고 신호 대 잡음비의 변화를 측정해 영상 화질에 미치는 지멘스 ADMIRE(Advanced Modeled Iterative Reconstruction)의 영향을 조사했다. 실험 결과에 따르면 ADMIRE Strength가 커질수록 잡음은 감소하고 신호는 증가하여, 결론적으로 신호 대 잡음비는 증가하는 것으로 나타났다. ADMIRE는 기존 영상 재구성 알고리즘인 FBP와 비교하여 잡음을 28~61%까지 줄일 수 있으며, 신호 대 잡음비는 16~100%까지 향상시킨다.

복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구 (Study on Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique)

  • 강민;최남길;한재복;김욱;장영일;송종남
    • 한국방사선학회논문지
    • /
    • 제9권1호
    • /
    • pp.9-16
    • /
    • 2015
  • 이중에너지 기법을 이용한 복부 CT 검사에서 적정한 조영제 양에 대하여 알아보고자 하였다. 일반적인 단일에너지 복부 CT 검사를 시행했던 환자들 중 이중에너지 기법을 이용하여 추적검사를 시행한 30명을 대상으로 하였다. 단일에너지 복부 검사에서 사용했던 조영제 양 대비 30%, 40%, 50%, 60%, 70%로 각각 설정하여 영상을 획득한 후 대동맥, 하대정맥, 간문맥, 간실질에 관심영역을 설정하여 조영증강정도(hounsfield unit; HU)를 구하여 단일에너지에서 측정된 부위와의 값을 비교 분석하였다. 그 결과 기존대비 60%로 조영제를 설정한 군에서는 대동맥 HU : $210.80{\pm}13.609$, 하대정맥 HU : $190.40{\pm}25.215$, 간문맥 $198.40{\pm}21.232$, 간실질 HU : $119.20{\pm}7.98$로 각각 측정되었으며. 단일에너지 복부 CT 검사는 대동맥 HU : $205.40{\pm}16.426$, 하대정맥 HU : $188.20{\pm}21.476$, 간문맥 HU : $195.40{\pm}22.744$, 간실질 HU : $121.00{\pm}6.595$ 이었다. 따라서 이중에너지를 이용하여 복부 조영 CT검사를 시행할 때 조영제의 양을 60%로 설정한 후 검사하는 것이 각 장기에서의 단일에너지 조영검사시와 비슷한 조영증강정도를 획득할 수 있어 기존 조영제 양의 감소와 동시에 조영제를 낮은 속도로 주입할 수 있어 신장기능 저하환자, 정맥혈관이 약한 환자, 과거 조영제 부작용이 있었던 환자에게 유용한 검사라 사료된다.

CT상의 HU 수치에 따른 유한요소모델을 이용한 RME 사용에 따른 응력분포에 대한 연구 (Stress Distribution following Rapid Maxillary Expansion using Different Finite Element Model according to Hounsfield Unit Value in CT Image)

  • 윤병선;차경석;정동화
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.313-326
    • /
    • 2007
  • With rising prevalency of mouth breathing children caused by developing civilization and increasing pollution, there are many maxillary transverse discrepancy patients with undergrowth of maxilla. For improving this, maxillary mid-palatal suture splitting was often performed. The purpose of this study was to analyse the stress distribution on the craniofacial suture and cranium after rapid maxillary expansion by finite element model. The boy(13Y6M) was chosen for taking computed-tomography for finite element model. Three-dimensional model of maxilla, first premolar, first molar, buccal and lingual part of rapid maxillary expansion were constructed. 1. The alveolar bone adjacent to the first molar and the first premolar that was affected directly by rapid maxillary expansion was displaced laterally approximately 4.04mm at maximum. The force decreased toward anterior region and frontal alveolar bone displaced laterally about 3.18mm. 2. A forward maximum displacement was exhibited at zygomatic process middle region. 3. At maximum, maxillary median part experienced 0.973mm downward repositioning and 0.65mm upward repositioning at lateral alveolar bone. 4. Von mises stress was observed the largest stress distribution around teeth and zygomatic buttress. 5. The largest tensile force was observed around alveolar bone of teeth, while compression force was observed at zygomatic buttress.

Distinction of Internal Tissue of Raw Ginseng Root Using a Computed Tomography Scanner

  • Jung, In-Chan;Jeong, In-Soo;Kim, Cheon-Suk
    • Journal of Ginseng Research
    • /
    • 제36권4호
    • /
    • pp.469-476
    • /
    • 2012
  • Raw ginseng root of Panax ginseng is graded according to its shape and the quality of its internal tissue. A variety of grades are sold with prices according to grade. If an inferior raw ginseng is purchased, the consumer experience an economic loss. This research was conducted in order to explore the possibility of developing a noninvasive method for investigating raw ginseng's internal tissue. It has been determined that computed tomography (CT) scanner images agreed with actual cross-sections of raw ginseng. CT images were obtained to assess the internal portions of raw ginseng, and CT scans of raw ginseng were thoroughly measured using the Hounsfield unit (HU) system, since it allows for a more detailed analysis compared to nuclear magnetic resonance imaging. HU is a measure of attenuation used for CT images, with each pixel being assigned a value using a scale on which air is defined as -1000, water as 0 and compact bone as +1000. It takes about one second to process are slice and produce an image of the raw ginseng by a one channel CT scanner. An image good enough to discriminate the internal tissues can be obtained in 1/24 seconds with a one-channel CT scanner. Using this method, images of raw ginseng can be obtained and the characteristics of the internal tissues can be observed in a short time.

골밀도를 고려한 척추의 생체역학적 평가 (Biomedical evaluation of the vertebra based on bone density)

  • 김동율;채수원;최귀원;이태수;박정율;서중근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1921-1924
    • /
    • 2005
  • In this paper, three-dimensional finite element analysis have been performed to investigate the biomechanics of vertebroplasty in patient. In order to apply various properties of the spine, the functional relation between the well-known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material property can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the spine and the clinical application can be expected.

  • PDF

골밀도를 고려한 척추성형술의 생체역학적 평가 (Biomechanical Evaluation of the Vertebroplasty Based on Bone Density)

  • 김동율;이태수;박정율;서중근;최귀원;채수원
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.185-194
    • /
    • 2006
  • In this paper, three dimensional finite element analyses have been performed to investigate the biomechanics of vertebroplasty in patient accurate FE models have been constructed from CT images of a PMMA injected vertebra. In order to apply various material properties of the spine(T12), the functional relation between the well known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material properties can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the vertebroplasty and its clinical applications can be expected.

보급형 3D프린터 재료가 CT 영상에 미치는 영향 분석 (Analysis of the Effect of Entry-Level 3D Printer Materials on CT Images)

  • 박세환;조현정;이성준;이송빈;박상협;류대연;허영철
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.673-680
    • /
    • 2022
  • 본 연구에서는 PLA를 기반으로 알루미늄, 나무, 구리, 카본, 대리석이 각각 20% 함유된 재질들의 CT number를 분석하고 영상에 어떠한 영향을 미치는지 분석하고자 하였다. 보급형 3D 프린터를 이용하여 5×30×30 ㎣(두께×직경×높이)의 원기둥 모양 팬텀을 제작하였다. 관전압을 80, 100, 120 kV로 변화시키고, 관전류초를 100, 200 mAs로 변화시켜 테이블 중앙에 놓인 팬텀을 총 6가지 조건으로 횡단 스캔하였다. Image J를 이용하여 원형의 ROI를 설정하고 물질부 CT number의 정량값과 주변부 CNR의 정량값을 구하였다. 물질부의 CT number 평균값은 PLA-나무20%, PLA-대리석20%, PLA-카본20%, PLA-100%, PLA-알루미늄20%, PLA-구리20% 순으로 높아졌고(p<0.05), kV 증가에 따른 CT number는 음의 상관성을 확인하였다. 주변부의 CNR값은 PLA-대리석20%, PLA-구리20%, PLA-카본20%, PLA-나무20%, PLA-알루미늄20%, PLA-100% 순으로 증가 됨을 확인하였다(p<0.05). 각 재료별 HU 값과 유사한 인체 장기는 PLA-구리20%는 치밀골, PLA-알루미늄20%는 해면골, PLA-100%는 응고된 혈액, PLA-카본20%와 PLA-대리석20%는 간, 근육, 비장, PLA-나무20%는 지방과 유사한 값이었다. 또한 모든 재료에서 필라멘트 주변부 영상을 흐리게 하는 흐림 현상을 확인하였고 특히 PLA-100%에서 영상 주변부 흐림 현상이 가장 많은 것을 확인하였다. 따라서 의료용팬텀 제작의 재질을 선정할 때 목표 장기의 HU 값을 반영하고, 팬텀 주변부의 흐림 현상을 고려하는 것이 바람직하다고 판단하며 본 연구가 기초 자료를 제공할 수 있을 것이라 사료된다.

임플란트 식립 부위의 골밀도 평가에 관한 연구 (The study of bone density assessment on dental implant sites)

  • 박수원;장수미;최병환;손한나;박봉찬;김창환;손장호;성일용;이지호;조영철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.417-422
    • /
    • 2010
  • Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site ($827.6{\pm}151.4$), followed by the mandibular molar site ($797{\pm}135.1$), mandibular premolar site ($753.8{\pm}171.2$), maxillary anterior site ($726.3{\pm}154.4$), maxillary premolar site ($656.7{\pm}173.8$) and maxillary molar site ($621.5{\pm}164.9$). The ISQ value was the highest in the mandibular premolar site ($81.5{\pm}2.4$) followed by the mandibular molar site ($80.0{\pm}5.7$), maxillary anterior site ($77.4{\pm}4.1$), mandibular anterior site ($76.4{\pm}11.9$), maxillary premolar site ($74.2{\pm}14.3$) and maxillary molar site ($73.7{\pm}7.4$). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

임플란트 시술의 문제점과 의료분쟁 (Problems of Implant Procedure and Medical Disputes)

  • 이태희;송영지
    • 의료법학
    • /
    • 제17권1호
    • /
    • pp.281-297
    • /
    • 2016
  • 임플란트 시술 부위의 정확하고 객관적인 골조직의 평가는 치료계획을 세우고 결과를 예측하는 과정에서 중요한 요소로 작용한다. 골조직 평가는 임플란트가 시술되는 치조골의 상부구조 제작 시기를 결정할 수 있는 가장 객관적 방법이다. 하지만 이러한 골조직 평가가 치과 임상의의 주관적인 견해에 의해서 기초가 수립되기 때문에 상당한 모순을 내포하고 있다. 치과임상들 역시 골조직에 대한 주관적인 평가의 문제점을 지적하고 있다. 따라서 정확하고 객관적인 기준을 마련하는 것이 요청된다. 과거 골밀도 평가는 임플란트 시술시 드릴링 작업과 같이 치고임상의의 주관적인 감각에 의존하였다. 그러나 이제는 컴퓨터 단층 촬영에서 나타난 각 픽셀에 대한 CT의 HU(Hounsfield unit)값을 이용하여 객관적이고 정확한 분류가 가능하게 되었다. Misch와 Kircos는 주관적인 골밀도 분류를 수치화하여 골조직을 D1부터 D5까지 다섯 단계로 나누었다. 하지만, 이 분류 방법도 정량화 된 테이터를 이용한 것이 아니라 감각에 의해 분류한 것을 단지 수치화한 것이다. 그러므로 더욱 객관적이고 정량화된 데이터의 비교 분석을 통해 임플란트 시술 부위의 골질을 평가할 필요가 있다. 임플란트시술은 치과의료분쟁에서 가장 높은 빈도를 차지하고 있다. 따라서 객관적인 검사와 합리적인 치료방법을 도입하여 임플란트 시술이 이루어진다면 의료분쟁에서 보다 합리적인 결과에 도달할 수 있을 것이며, 임플란트 시술의 실패율도 낮아 질 것이다. 따라서 본 연구의 궁극적인 목적은 객관적이고 정량화된 데이터를 기초로 한 법적으로 새로운 기준을 만들어서 환자뿐만 아니라 치과 임상의에게도 발생될 수 있는 의료분쟁을 최소화하고 하고자 하는 것이다.

  • PDF