• Title/Summary/Keyword: Hounsfield

Search Result 164, Processing Time 0.024 seconds

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study

  • Lee, Ji-Hyun;Kim, Hee-Jin;Yun, Jeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.20-29
    • /
    • 2017
  • Purpose: The microstructural characteristics of trabecular bone were identified using micro-computed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb.Sp varied markedly across the bone quality categories (D1: $0.59{\pm}0.22mm$, D4: $1.20{\pm}0.48mm$), whereas Tb.Th had similar values (D1: $0.30{\pm}0.08mm$, D4: $0.22{\pm}0.05mm$). Conclusions: Bone quality depended on Tb.Sp and number-that is, endosteal space architecture-rather than bone surface and Tb.Th. Regardless of bone quality, Tb.Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.

Distinction of Internal Tissue of Raw Ginseng Root Using a Computed Tomography Scanner

  • Jung, In-Chan;Jeong, In-Soo;Kim, Cheon-Suk
    • Journal of Ginseng Research
    • /
    • v.36 no.4
    • /
    • pp.469-476
    • /
    • 2012
  • Raw ginseng root of Panax ginseng is graded according to its shape and the quality of its internal tissue. A variety of grades are sold with prices according to grade. If an inferior raw ginseng is purchased, the consumer experience an economic loss. This research was conducted in order to explore the possibility of developing a noninvasive method for investigating raw ginseng's internal tissue. It has been determined that computed tomography (CT) scanner images agreed with actual cross-sections of raw ginseng. CT images were obtained to assess the internal portions of raw ginseng, and CT scans of raw ginseng were thoroughly measured using the Hounsfield unit (HU) system, since it allows for a more detailed analysis compared to nuclear magnetic resonance imaging. HU is a measure of attenuation used for CT images, with each pixel being assigned a value using a scale on which air is defined as -1000, water as 0 and compact bone as +1000. It takes about one second to process are slice and produce an image of the raw ginseng by a one channel CT scanner. An image good enough to discriminate the internal tissues can be obtained in 1/24 seconds with a one-channel CT scanner. Using this method, images of raw ginseng can be obtained and the characteristics of the internal tissues can be observed in a short time.

Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.

A Solid Anterior Mediastinal Mass (전종격동 고형성 종괴)

  • You, Young-Kyu;Ahn, Young-Soo;Rha, Dong-Jib;Kim, Do-Jin;Lee, Sang-Moo;Kim, Hyeon-Tae;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.747-750
    • /
    • 1993
  • A 51-year-old male was admitted due to mediastinal mass. Chest PA showed a $4{\times}5$ cm sized round mass on right lower paratracheal area. The chest computerized tomogram showed cystic mass located between superior vena cava and trachea. This cystic mass was composed of variable internal architecture with Hounsfield unit(HU) from -44.4 to +25.5. The resected cystic mass revealed ectodermal, mesodermal, and endodermal structures. We report a case of anterior mediastinal cystic teratoma confirmed by open thoracotomy.

  • PDF

Measurement Method of the Masseter Muscle Volume Using 3D Computed Tomography (3D CT를 이용한 교근의 부피측정)

  • Baek, Jung Hwan;Choi, Jong Woo;Yoo, Sun Kuk;Kim, Yong Oock;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.589-592
    • /
    • 2005
  • Since G.N. Hounsfield's clinical use of computed tomography in 1971, digital imaging technique using computers has shown an eye opening progress. Progress has made 3-dimensional understanding of not only facial bones but muscles and other connective tissues possible through 3-dimensional reconstruction of preexisting tomographical images. Also, quantitative analysis of density, distance, volume has become possible, allowing objective analysis of preoperative and postoperative states through imaging. The authors measured the masseter muscle volume of 20 normal individuals and 8 female patients through 3-D reconstructive CT imaging and made a statistical analysis of the measurements. The method used in our study may be applied to the diagnosis of disease causing the change of the facial volume and presurgical design as a useful tool to provide objective information on the evaluation of surgery outcome.

The Effect of Advanced Modeling Iterative Reconstruction(ADMIRE) on the Quality of CT Images : Non-contrast CT in Chest (고급 모델링 반복 재구성법(ADMIRE)이 CT 영상의 화질에 미 치는 영향: 흉부 비조영 CT에서)

  • Lee, SangHeon;Lee, HyoYeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • We examined the effect of Siemens ADMIRE (Advanced Modeled Iterative Reconstruction) on image quality by measuring changes in HU, noise, and SNR of background air, fat, muscle, and background signals on a chest CT scan. Experimental results show that as the ADMIRE Strength increases, the noise decreases and the signal increases, consequently the signal-to-noise ratio increases. ADMIRE can reduce noise by 28 ~ 61% compared to FBP, which is a conventional image reconstruction algorithm, and improves SNR by 16 ~ 100%.

Estimation of Lower Jaw Density using CT data

  • Jargalsaikhan, Ariunbold;Sengee, Nyamlkhagva;Telue, Berekjan;Ochirkhvv, Sambuu
    • Journal of Multimedia Information System
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Bone density is one of the factors in the early failure of dental implants and doctors should make a preoperative assessment of jaw bone density using patient's CT data before dental implant surgery in order to find out whether the patient has osteoporosis and osteopenia. The main goal of this study was to propose a method that based on image processing techniques in order to provide accurate information about where to drill and place an abutment screw of implants in the jaw bone for doctors and reduce human activity for the estimation of the local cancellous bone density of mandible using CT data. The experiment was performed on a computed tomography data of the jaw bone of two different individuals. We assumed that the result of the estimation of jaw bone density depends on the angle of drilling and average HU (Hounsfield Unit) values were used to evaluate the quality of local cancellous bone density of mandible. As a result of this study, we have been developed a toolbox that can be used to estimate jaw bone density automatically and found a positive correlation between the angle of the drill and time complexity but a negative correlation between the diameter of the drill and time complexity.

Presurgical assessment of splenic tumors in dogs: a retrospective study of 57 cases (2012-2017)

  • Lee, Mokhyeon;Park, Jiyoung;Choi, Hojung;Lee, Haebeom;Jeong, Seong Mok
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.827-834
    • /
    • 2018
  • The purpose of this study was to evaluate the clinical and imaging characteristics of canine splenic tumors and to establish guidelines for the presurgical assessment of splenic tumors in dogs. Fifty-seven dogs that underwent total splenectomy for the treatment of splenic tumors were evaluated by examining medical records, hematologic results, diagnostic imaging results, and histopathologic results. The maximum lesion size from ultrasonography was significantly different between malignant and benign tumors (p = 0.002). There was a correlation between tumor margination and type of splenic tumors (p = 0.045). Precontrast lesion attenuation on computed tomography was significantly different between splenic malignant and benign tumors (p = 0.001). The mean ${\pm}$ SD precontrast lesion attenuation of malignant tumors was $40.3{\pm}5.9$ Hounsfield units (HU), and for benign tumors, it was $52.8{\pm}6.8HU$. In conclusion, some variables of the imaging examination could be used to distinguish the type of splenic tumor. Based on the study results, using a diagnostic flowchart would be effective in increasing the survival rate of patients with splenic malignant tumors. In addition, fine needle aspiration or magnetic resonance imaging prior to surgical exploration and histopathologic examination may be useful in achieving a more accurate diagnosis.

The Osteoporotic Condition as a Predictive Factor for Hemorrhagic Transformation in Acute Cardioembolic Stroke

  • Won, Yu Deok;Kim, Jae-Min;Ryu, Je-Il;Koh, Seong-Ho;Han, Myung-Hoon;Cheong, Jin-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.763-775
    • /
    • 2021
  • Objective : Hemorrhagic transformation (HT) can be occurred after acute cerebral infarction. HT can worse symptoms in severe cases and adversely affect long-term prognosis. As bone and vascular smooth muscle are composed of type 1 collagen, we aimed to identify a potential relationship between bone mineral density (BMD) and HT after acute cardioembolic stroke. Methods : As an indicator of BMD, we used mean frontal skull Hounsfield unit (HU) values on brain computed tomography (CT). Multivariative hazard ratios were calculated using Cox regression analysis to identify whether the osteoporotic condition was an independent predictor of HT after acute cardioembolic stroke. Results : This 11-year analysis enrolled 506 patients who diagnosed as acute cardioembolic infarction. The first tertile of skull HU value was an independent predictor of HT development compared to the third tertile (hazard ratio, 2.12; 95% confidence interval, 1.13-3.98; p=0.020). We observed no interactions between age and skull HU with respect to HT statistically. Conclusion : The results of this study revealed an association between osteoporotic conditions and HT development after acute cardioembolic stroke. A convenient method to measure the cancellous bone HU value of the frontal skull using brain CT images may be useful for predicting HT in patients with acute cerebral infarction.