• Title/Summary/Keyword: Hounsfield

검색결과 164건 처리시간 0.022초

Quantitative Assessment of Salivary Gland washout in Clinically Healthy Dogs

  • Jang, Won-seok;Hwang, Tae-sung;Jung, Dong-in;Lee, Jae-hoon;Lee, Hee-chun
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.28-33
    • /
    • 2020
  • The aims of this study were to obtain the normal ranges of enhancement parameters for salivary gland in dynamic CT and to investigate the effects of fasting time on contrast enhancement in clinically normal beagle dogs. With five healthy beagle dogs, dynamic CT examination was performed according to fasting times (as fasting times, 12hours, 0 min, 20 min, 40 min, 1 hours, 6 hours, 24 hours). In normal beagles with 12hours fasting, enhancement parameters through the preliminary study were as follows: ImaxA - 472 .49 ± 19.01 HU; ImaxS - 138.95 ± 6.2 5 HU; TmaxA - 25.8 ± 1.79 sec; TmaxS - 69.0 ± 23.11 sec; Teq - 80.5 ± 6.61 sec; T-Aeq - 54.5 ± 5.51 sec (Imax - peak enhancement; Tmax - time to peak enhancement; Teq - time to equilibrium phase; T-Aeq - time between peak enhancement in the common carotid artery and onset of the equilibrium phase; A - common carotid; S - submandibular gland; HU - Hounsfield unit). Additionally, ImaxA and ImaxS were significantly increased in 40 min after eating. Because these results associated with postprandial hemodynamic changes can make the diagnosis of salivary gland diseases more difficult, sufficient fasting time is important for accurate diagnosis.

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

Reduction in post extraction waiting period for dental implant patients using plasma rich in growth factors: an in vivo study using cone-beam computed tomography

  • Arya, Varun;Malhotra, Vijay Laxmy;Rao, JK Dayashankara;Kirti, Shruti;Malhotra, Siddharth;Sharma, Radhey Shyam
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.285-293
    • /
    • 2019
  • Objectives: This study examined the effects of plasma-rich growth factors (PRGF) on accelerating bone regeneration/repair in fresh extraction sockets, and determined the quality and quantity of bone by assessing the bone density using cone-beam computed tomography (CBCT). Materials and Methods: Twenty patients, who had undergone bilateral extractions, were included in this study. In one extraction socket, PRGF was used and covered with an autologous fibrin plug. Nothing was used in the opposite side extraction socket. Thirteen weeks post extraction, the level of bone regeneration was evaluated on both sides with CBCT. Results: At the end of the study, the mean bone density according to the Hounsfield units (HU) in the control group and PRGF group was 500.05 HU (type III bone type) and 647.95 HU (type II bone type), respectively. Conclusion: This study recommends the use of PRGF in post extraction sites to accelerate the rate of bone regeneration and improve the quality of regenerated bone. The technique to process PRGF was simple compared to previously mentioned techniques used for platelet-rich plasma (PRP) preparation. PRP preparation requires a two-cycle centrifugation procedure, leading to a longer processing time.

Pattern of buccal and palatal bone density in the maxillary premolar region: an anatomical basis of anterior-middle superior alveolar (AMSA) anesthetic technique

  • Ahad, Abdul;Haque, Ekramul;Naaz, Sabiha;Bey, Afshan;Rahman, Sajjad Abdur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.387-395
    • /
    • 2020
  • Background: The anterior-middle superior alveolar (AMSA) anesthetic technique has been reported to be a less traumatic alternative to several conventional nerve blocks and local infiltration for anesthesia of the maxillary teeth, their periodontium, and the palate. However, its anatomic basis remains controversial. The present study aimed to determine if the pattern of cortical and cancellous bone density in the maxillary premolar region can provide a rationale for the success of the AMSA anesthetic technique. Method: Cone-beam computed tomography scans of 66 maxillary quadrants from 34 patients (16 men and 18 women) were evaluated using a volumetric imaging software for cortical and cancellous bone densities in three interdental regions between the canine and first molar. Bone density was measured in Hounsfield units (HU) separately for the buccal cortical, palatal cortical, buccal cancellous, and palatal cancellous bones. Mean HU values were compared using the Mann-Whitney U test and one-way ANOVA with post-hoc analysis. Results: Cancellous bone density was significantly lower (P ≤ 0.001) in the palatal half than in the buccal half across all three interdental regions. However, there was no significant difference (P = 0.106) between the buccal and palatal cortical bone densities at the site of AMSA injection. No significant difference was observed between the two genders for any of the evaluated parameters. Conclusions: The palatal half of the cancellous bone had a significantly lower density than the buccal half, which could be a reason for the effective diffusion of the anesthetic solution following a palatal injection during the AMSA anesthetic technique.

Evaluating Paraspinal Back Muscles Using Computed Tomography (CT) and Magnetic Resonance Imaging (MRI): Reliability Analysis and Correlation with Intervertebral Disc Pathology

  • Hwang, Eunjin;Antony, Chermaine Deepa;Choi, Jung-Ah;Kim, Minsu;Khil, Eun Kyoung;Choi, Il
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권2호
    • /
    • pp.109-117
    • /
    • 2021
  • Purpose: To investigate the reliability of CT and MRI for quantitative and qualitative analyses of lumbar paraspinal muscle fatty infiltration (PSFI) and correlation of PSFI with intervertebral disc pathology. Materials and Methods: Lumbar spine CT and MRI of 36 subjects were reviewed retrospectively. Two observers independently outlined lumbar paraspinal muscles at each mid-intervertebral disc level. Paraspinal muscles on CT and MRI were graded according to the Goutallier grading system (GGS). The area, mean value, and standard deviation (SD) of the Hounsfield unit (HU) were obtained. Intervertebral discs were assessed on axial image of T2WI at each level. Correlations between qualitative and quantitative data and intervertebral disc pathology, age, and sex were evaluated. Results: Inter- and intra-observer agreements for results of GGS on MRI were substantial (κ = 0.79) and moderate (κ = 0.59), respectively. Inter- and intra-observer agreements for results of GGS on CT were almost perfect (κ = 0.88) and substantial (κ = 0.66), respectively. Quantitative measurements of HU showed almost perfect inter- and intra-observer reliabilities (κ = 0.82 and κ = 0.99, respectively). There were statistically significant correlations between intervertebral disc pathology and PSFI at L1-2, L2-3, and L4-5 levels on MRI and at L1-2 and L3-4 levels on CT. Age showed significant correlation with results of GGS at all levels on CT and MRI. Conclusion: This study showed that GGS results and HU measurements could be useful for evaluating PSFI because they showed correlations with intervertebral disc pathology results at certain levels.

성별과 폐경기 나이가 막성골의 두께와 밀도에 미치는 영향 : 측두골 비늘부위 전산화단층영상을 중심으로 (Effect of Sex and Menopausal Age on Thickness and Density of Membranous Bone : Focused on Computed Tomography in Squamous Portion of Temporal Bone)

  • 지명훈;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.211-218
    • /
    • 2021
  • The purpose of this study was to investigate the effect of sex and menopausal age on the thickness and density of squamous portion of the temporal bone as the membranous bone. Patients who visited a general hospital in Chungnam and had a computed tomography (CT) examination of the head. A retrospective study was conducted with 120 subjects (30 men under 55 years old, 30 men over 56 years old, 30 women under 55 years old, and 30 women over 56 years old). Axial images of the squamous portion in the temporal bone were obtained from CT of the head. For this image, a slice sensitive profile (SSP) was acquired with an image analysis program and these were evaluated. The thickness was measured by using a digital ruler to measure the full width at half maximum (FWHM) of the SSP, and the density was measured in hounsfield unit (HU). These by gender were measured to be about 0.5 mm thinner in the temporal bone in men than in women, and there was a significant difference. The density was measured to be about 200 HU higher in women than in men of it, and there was a significant difference. As a result, it in women was thicker and had a lower density. The thickness of it in men and women over 56 years of age was 0.8 mm or more thicker in women and less than 400 HU in density. As a result, the women group over the age of 56 showed a distinct increase in thickness and decrease in density, different from other target groups. It is expected that the results of this study could be used as basic data for a new bone density measurement site study.

토모테라피에서 쌀 볼루스 팬텀의 유용성 평가: 팬텀연구 (Evaluating the Usefulness of Rice Bolus Phantom in Tomotherapy: Phantom Study)

  • 김대건;정재홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.663-669
    • /
    • 2021
  • The purpose of this study was to evaluate the usefulness of the rice bolus for upper-lower extremity radiation therapy by Tomotherapy. The computed tomography images were obtained for air, water, and rice bolus. The average and standard deviation of the Hounsfield unit (HU) were measured for image evaluation. The conformity index (CI) and homogeneity index (HI) were calculated for dose distribution of the planning target volume (PTV) which was treated by direct mode with gantry angle (90 and 270 angle). The point dose of a total of ten axial planes was measured to confirm the different regions. The mean of HU was -999.72 ± 0.72 at the air. The water and rice bolus were -0.13 ± 1.65 and -170 ± 27.2, respectively. The CI (HI) of PTV was 0.96 (1.36) at the air. 0.95 (1.04) at the water bolus, and 0.95 (1.04) at the rice bolus. The maximum dose for air was 136 cGy which is about 32% higher than 103 cGy for water and 104 cGy for rice bolus. There was a statistical difference for point dose between air and water including rice bolus (p=0.04), however, no statistical difference between water and rice bolus (p=0.579).The rice bolus phantom for extremities radiation therapy could be not only the optimized dose distribution but also the convenience and equipment safety at Tomotherapy. However, additional research will be necessary to more accurately verify the clinical usefulness of rice bolus phantom due to not enough examination.

Computed tomographic features of the temporomandibular joint in 10 Jeju horses

  • Lee, Seyoung;Lee, Eun-Bee;Park, Kyung-Won;Jeong, Hyohoon;Shin, Kwang-Yun;Kweon, Young-Park;Seo, Jong-pil
    • Journal of Veterinary Science
    • /
    • 제23권3호
    • /
    • pp.44.1-44.10
    • /
    • 2022
  • Background: The equine temporomandibular joint (TMJ) has a complex anatomical structure that makes diagnosis of TMJ disorders difficult. Computed tomography (CT) is now available in equine medicine; hence, TMJ evaluation has become more convenient. Objectives: The objectives of this study were to describe the CT features of the TMJ in Jeju horses and to compare these features with those of Thoroughbreds. Methods: In this report, the TMJs of 10 Jeju horses (mean age: 4.5 ± 1.9 yr; mean body weight: 282.6 ± 40.3 kg) and 6 Thoroughbreds (mean age: 7.3 ± 1.6 yr; mean body weight: 479.7 ± 44.0 kg) were examined using CT. After CT scanning, the Hounsfield units (HU) and height to width ratio (H:W) of the mandibular condyle were measured. Results: The mean H:W in Jeju horses was significantly lower than that in Thoroughbreds. The mean HU in Jeju horses was lower than that in Thoroughbreds; however, the difference was not significant. The most frequent CT finding was an irregular medial margin of the mandibular condyle in both breeds. Conclusions: In this study, the shape of the mandibular condyle in Jeju horses was flatter than that in Thoroughbreds. This report could be useful in evaluating the TMJ in Jeju horses. Moreover, CT could be a pragmatic choice for the examination of the TMJ in horses.

Estimation of Noise Level and Edge Preservation for Computed Tomography Images: Comparisons in Iterative Reconstruction

  • Kim, Sihwan;Ahn, Chulkyun;Jeong, Woo Kyoung;Kim, Jong Hyo;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.92-98
    • /
    • 2021
  • Purpose: This study automatically discriminates homogeneous and structure edge regions on computed tomography (CT) images, and it evaluates the noise level and edge preservation ratio (EPR) according to the different types of iterative reconstruction (IR). Methods: The dataset consisted of CT scans of 10 patients reconstructed with filtered back projection (FBP), statistical IR (iDose4), and iterative model-based reconstruction (IMR). Using the 10th and 85th percentiles of the structure coherence feature, homogeneous and structure edge regions were localized. The noise level was estimated using the averages of the standard deviations for five regions of interests (ROIs), and the EPR was calculated as the ratio of standard deviations between homogeneous and structural edge regions on subtraction CT between the FBP and IR. Results: The noise levels were 20.86±1.77 Hounsfield unit (HU), 13.50±1.14 HU, and 7.70±0.46 HU for FBP, iDose4, and IMR, respectively, which indicates that iDose4 and IMR could achieve noise reductions of approximately 35.17% and 62.97%, respectively. The EPR had values of 1.14±0.48 and 1.22±0.51 for iDose4 and IMR, respectively. Conclusions: The iDose4 and IMR algorithms can effectively reduce noise levels while maintaining the anatomical structure. This study suggested automated evaluation measurements of noise levels and EPRs, which are important aspects in CT image quality with patients' cases of FBP, iDose4, and IMR. We expect that the inclusion of other important image quality indices with a greater number of patients' cases will enable the establishment of integrated platforms for monitoring both CT image quality and radiation dose.