• Title/Summary/Keyword: Hot box

Search Result 90, Processing Time 0.023 seconds

Thermal analysis of two main CCS(cargo containment system) insultaion box by using experimental thermal properties (실험적 열적 물성치를 반영한 CCS 방열박스의 열전달 해석)

  • Choi, Sung-Woong;Roh, Jeong-U;Kim, Moo-Sun;Lee, Woo-Il
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.429-438
    • /
    • 2011
  • In this paper, experiment of thermal conductivity among thermal properties for CCS insulation material was carried out under the condition ranged from room temperature to cryogenic temperature. CCS insulation system should be sustained under cryogenic temperature($-163^{\circ}C$), and lots of investigations will be conducted how to block the heat to insulation material. CCS components which consist of various materials are especially the main interests, and how the temperature of the entire CCS along the location is should be investigated through these studies. With the experimental thermal properties, the steady state thermal analysis of the entire cargo system was conducted. When the LNG leaked through the insulation system with external impact, temperature distribution and thermal safety of secondary barrier, especially plywood and hull structure, was observed.

Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation (BES를 이용한 온실용 보온커튼의 관류열전달계수 산정)

  • Rasheed, Adnan;Lee, Jong Won;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.294-301
    • /
    • 2018
  • In winter, thermal screens are widely used to reduce heat loss from greenhouse to save energy. Unfortunately, not much data are available to the farmer to compare thermal screens while selecting the one that meets their specific requirements. Thus, there is a need to investigate the thermal performance of thermal screens. To address this issue, the Building Energy Simulation (BES) model of a hot box was used to calculate the overall heat transfer coefficient (U-value) of the thermal screens. To validate the model, computed and experimental U-values of single-and double-layered polyethylene (PE) material were compared. This validated model was used to predict the U-values of the selected thermal screens under defined weather conditions. We quantified the U-values of each selected material and significant changes in their U-values were noted in response to different weather conditions. Notably, the thermal properties of the tested screens were taken from the previous literature to calculate U-values using the BES model. The U-values of the thermal screens can help researchers and farmers evaluate their screens and make pre-design decisions that suit their investment capabilities.

Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method (핫박스를 이용한 온실 피복재 및 보온재의 조합에 따른 관류열전달계수 측정)

  • Diop, Souleymane;Lee, Jong-Won;Na, Wook-Ho;Lee, Hyun-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 국내에서 상용되고 있는 온실 피복재 및 보온재의 조합에 따른 관류열전달계수를 핫박스를 이용하여 평가하는 것이다. 온실용 일중 및 이중 피복재와 이중 보온재의 조합에 대하여 야간천공복사 차단여부에 따른 관류열전달계수를 핫박스를 이용하여 실외에서 측정하였다. 처리조건은 일중피복, 이중피복, 이중피복과 이중 마트보온재 및 이중피복과 이중 다겹보온재의 조합조건과 천공복사 유무에 따른 조건이며 총 8가지이다. 제작된 핫박스는 상시 변화하는 외부의 기상조건하에서도 내부온도를 설정된 온도로 일정하게 잘 유지할 수 있었다. 온실 피복재 및 보온재의 관류열전달계수를 측정하는 실내용 측정장치는 반드시 야간천공복사를 모의할 수 있는 측정장치가 되어야 할 것이다. 야간복사를 차단함으로서 온실의 열 손실을 줄여 보온효과를 얻을 수 있을 것으로 분석되었다. 모든 피복방식에 대해 야간복사 차단장치 유무에 관계없이 높은 풍속에서의 관류열전달계수가 낮은 풍속에서보다 더 큰 것으로 나타났다. 본 연구에서 사용된 측정기법을 사용하면 국내에서 생산되는 피복재 및 보온재의 관류열전달 특성을 정량적으로 비교할 수 있을 것으로 기대된다.

The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance (단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가)

  • Cho, Soo;Kim, Seok-Hyun;Eom, Jae-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test (가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구)

  • Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

Effect of Deer Antler Extract on Muscle Differentiation and 5-Aminoimidazole-4-Carboxamide Ribonucleoside (AICAR)-Induced Muscle Atrophy in C2C12 Cells

  • Jo, Kyungae;Jang, Woo Young;Yun, Beom Sik;Kim, Jin Soo;Lee, Hyun-Sun;Chang, Yeok Boo;Suh, Hyung Joo
    • Food Science of Animal Resources
    • /
    • v.41 no.4
    • /
    • pp.623-635
    • /
    • 2021
  • The effect of deer antler extract on muscle differentiation and muscle atrophy were evaluated to minimize muscle loss following aging. Various deer antler extracts (HWE, hot water extract of deer antler; FE, HWE of fermented deer antler; ET, enzyme-assisted extract of deer antler; UE, extract prepared by ultrasonication of deer antler) were evaluated for their effect on muscle differentiation and inhibition of 5-aminoimidazole-4-carboxamide ribonucleoside (AICAR)-induced muscle atrophy in C2C12 cells. Morphological changes according to the effect of antler extracts on muscle differentiation were confirmed by Jenner-Giemsa staining. In addition, the expression levels of genes related to muscle differentiation and atrophy were confirmed through qRT-PCR. In the presence of antler extracts, the length and thickness of myotubes and myogenin differentiation 1 (MyoD1) and myogenic factor 5 (Myf5) gene expression were increased compared to those in the control group (CON). Gene expression of AMP-activated protein kinase (AMPK), MyoD1, and myogenin, along with the muscle atrophy factors muscle RING finger-1 (MuRF-1) and forkhead box O3a (FoxO3a) upon addition of deer antler extracts to muscle-atrophied C2C12 cells was determined by qRT-PCR after treatment with AICAR. The expression of MuRF-1 and FoxO3a decreased in the groups treated with antler extracts compared to that in the group treated with AICAR alone. In addition, gene expression of MyoD1 and myogenin in the muscle atrophy cell model was significantly increased compared that into the CON. Therefore, our findings indicate that antler extract can increase the expression of MyoD1, Myf5 and myogenin, inhibit muscle atrophy, and promote muscle differentiation.

Study on Manufacturing Process of Hollow Main Shaft by Open Die Forging (자유단조공법을 통한 중공형 메인샤프트 제조공정에 관한 연구)

  • Kwon, Yong Chul;Kang, Jong Hun;Kim, Sang Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.221-227
    • /
    • 2016
  • The main shaft is one of the key components connecting the rotor hub and gear box of a wind power generator. Typically, main shafts are manufactured by open die forging method. However, the main shaft for large MW class wind generators is designed to be hollow in order to reduce the weight. Additionally, the main shafts are manufactured by a casting process. This study aims to develop a manufacturing process for hollow main shafts by the open die forging method. The design of a forging process for a solid main shaft and hollow shaft was prepared by an open die forging process design scheme. Finite element analyses were performed to obtain the flow stress by a hot compression test at different temperature and strain rates. The control parameters of each forging process, such as temperature and effective strain, were obtained and compared to predict the suitability of the hollow main shaft forging process. Finally, high productivity reflecting material utilization ratio, internal quality, shape, and dimension was verified by the prototypes manufactured by the proposed forging process for hollow main shafts.

Effect of Transportation at High Ambient Temperatures on Physiological Responses, Carcass and Meat Quality Characteristics in Two Age Groups of Omani Sheep

  • Kadim, I.T.;Mahgoub, O.;AlKindi, A.Y.;Al-Marzooqi, W.;Al-Saqri, N.M.;Almaney, M.;Mahmoud, I.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.3
    • /
    • pp.424-431
    • /
    • 2007
  • The aim of this study was to determine the effects of short road transportation in an open truck during hot season on live weight shrink, physiological responses, and carcass and meat quality of Omani sheep at 6 and 12 months of age. Thirty-six male sheep, 18 of each age group, were used. Age groups were assigned randomly to transported and not-transported groups. The transported group was transported to the slaughterhouse the day of slaughter in an open truck covering a distance of approximately 100 km. The average temperature during transportation was $37^{\circ}C$. The not-transported group was kept in a lairage of a commercial slaughterhouse with ad libitum feed and water for 48 h prior to slaughter. Blood samples were collected from sheep before loading and prior to slaughter via jugular venipuncture to assess their physiological response to transport in relation to hormonal levels. Animals were weighed just before loading onto a truck and after transport to assess shrinkage. Muscle ultimate pH, expressed juice, cooking loss percentage, WB-shear force value, sarcomere length and colour L*, a*, b* were measured on samples from longissimus dorsi, biceps femoris and semitendinosus muscles collected at 24 h postmortem at $1-3^{\circ}C$. Live weight shrinkage losses were 1.09 and 1.52 kg for 6 and 12 month transported sheep, respectively. The transported sheep had significantly (p<0.05) higher cortisol, adrenaline, noradrenaline, and dopamine concentration levels prior to slaughter at both ages than the not-transported sheep. Transportation significantly influenced meat quality characteristics of three muscles. Muscle ultimate pH and shear force values were significantly higher, while CIE L*, a*, b*, expressed juice and cooking loss were lower in transported than not-transported sheep. Age had a significant effect on meat quality characteristics of Omani sheep. These results indicated that short-term pre-slaughter transport at high ambient temperatures can cause noticeable changes in physiological and muscle metabolism responses in sheep.

Analysis Study on Successful Hit Elements of Faction Film < Gwang-hae: The Man Who Became King > (팩션영화 <광해, 왕이 된 남자>의 흥행 요소 분석 연구)

  • Kim, kyung-Sik;Jung, Ji-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.179-190
    • /
    • 2015
  • The current movie world is called the era of faction hot-wind by the continuous hits of faction films. The interpretation of the missing 15 days in the Annals of the Joseon Dynasty during Gwang-hae's reign based on one sentence in the record makes 'faction' that there was another king, drives audiences to absorption and imagination in the faction film < Gwang-hae: The Man Who Became King >. Furthermore, this film redefined historical king Gwang-hae as an ambivalent image through Gwang-hae and Ha-sun who filled the role as the king in it. Also, this film was appraised by reviews of reinterpretation of the image of leader who people want and hit success when the film released before the season of the presidential election. This thesis considers 'Faction' which is marked as a new image content and analyzes the film < Gwang-hae: The Man Who Became King > which is listed as Korea's all-time sixth highest grossing film with 12,323,555 tickets sold nationwide by three sections; < Gwang-hae: The Man Who Became King > as faction film, two images of Gwang-hae, and the appropriateness of film release time. In conclusion, the film < Gwang-hae: The Man Who Became King >. succeeded since it communicated with people to satisfy their wishes and taste. It would be necessary to study and analyze the basic connection between the trend of movies and Strategic elements of the box-office results, and a significant stride for progression of the movies.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.