• 제목/요약/키워드: Hot Water layer

검색결과 97건 처리시간 0.022초

고온 공기분사공정에 의한 유류오염대수층의 TPH 제거 (TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process)

  • 이준호;박갑성
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by NDT Method

  • Park, Kwang-June;Park, Yoon-Kyu;Kim, Eun-Ka
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.680-686
    • /
    • 1995
  • It has been known that water-side corrosion of fuel rods in nuclear reactor is accompanied with the loss of metallic wall thickness and pickup of hydrogen. This corrosion is one of the important limiting factors ill the operating life of fuel rods. In connection with the fuel cladding corrosion, a device to measure the water-side oxide layer thickness by means of the eddy-current method without destructing the fuel rod was developed by KAERI. The device was installed on the multi-function testing bench in the nondestructive test hot-cell and its calibration was carried out successfully for the standard rod attached with plastic thin films whose thicknesses are predetermined. It shows good precision within about 10% error. And a PWR fuel rod, one of the J-44 assembly discharged from Kori nuclear power plant Unit-2, has been selected for oxide layer thickness measurements. With the result of data analysis, it appeared that the oxide layer thicknesses of Zircaloy cladding vary with the length of the fuel rod, and their thicknesses were compared with those of the destructive test results to confirm the real thicknesses.

  • PDF

Investigation of transport of radionuclide in a thermal stratification test facility using radiotracer technique

  • Pant, Harish Jagat;Goswami, Sunil;Chafle, Sunil B.;Sharma, Vijay Kumar;Kotak, Vimal;Shukla, Vikram;Mishra, Amitanshu;Gohel, Nilesh C.;Bhattacharya, Sujay
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1449-1455
    • /
    • 2022
  • A radiotracer investigation was carried out in a Thermal Stratification Test Facility (TSTF) with objectives of investigating the dispersion and diffusion of radionuclide and effectiveness of the thermocline to minimize the radionuclide content in the hot water layer. Technetium-99m (99mTc) as sodium pertechnetate was used as a radiotracer in the investigation. Qualitative analysis showed that a thermocline is formed within the TSTF and is effective in preventing the transport of radionuclide from bottom section to the top section of the facility. It was found that the radiotracer injected at the bottom of the pool took about 17.4 h to disperse from bottom to the top of the facility. The results of the investigation helped in understanding the effectiveness of hot water layer and thus to minimize the pool top radiation levels.

STI-CMP 공정에서 Consumable의 영향 (Effects of Consumable on STI-CMP Process)

  • 김상용;박성우;정소영;이우선;김창일;장의구;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.185-188
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process is widely used for global planarization of inter-metal dielectric (IMD) layer and inter-layer dielectric (ILD) for deep sub-micron technology. However, as the IMD and ILD layer gets thinner, defects such as micro-scratch lead to severe circuit failure, which affect yield. In this paper, for the improvement of CMP process, deionized water (DIW) pressure, purified $N_2 \; (PN_2)$ gas, slurry filter and high spray bar were installed. Our experimental results show that DIW pressure and $PN_2$ gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. Also, the filter installation in CMP polisher could reduce defects after CMP process, it is shown that slurry filter plays an important role in determining consumable pad lifetime. The filter lifetime is dominated by the defects. However, the slurry filter is impossible to prevent defect-causing particles perfectly. Thus, we suggest that it is necessary to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of slurry filter. Finally, we could expect the improvements of throughput, yield and stability in the ULSI fabrication process.

  • PDF

CMP 공정의 설비요소가 공정 결함에 미치는 영향 (Effects of Various Facility Factors on CMP Process Defects)

  • 박성우;정소영;박창준;이경진;김기욱;서용진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.191-195
    • /
    • 2002
  • Chemical mechanical Polishing (CMP) process is widely used for the global planarization of inter-metal dielectric (IMD) layer and inter-layer dielectric (ILD) for deep sub-micron technology. However, as the IMD and ILD layer gets thinner, defects such as micro-scratch lead to severe circuit failure, which affect yield. In this paper, for the improvement of CMP process, deionized water (DIW) pressure, purified $N_2$ ($PN_2$) gas, point of use (POU) slurry filler and high spray bar (HSB) were installed. Our experimental results show that DW pressure and P$N_2$ gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. Also, the filter installation in CMP polisher could reduce defects after CMP process, it is shown that slurry filter plays an important role in determining consumable pad lifetime. The filter lifetime is dominated by the defects. However, the slurry filter is impossible to prevent defect-causing particles perfectly. Thus, we suggest that it is necessary to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of slurry filter Finally, we could expect the improvements of throughput, yield and stability in the ULSI fabrication process.

온돌 난방에 대한 동적 시뮬레이션 및 분석 (Method and Analysis of Dynamic Simulation for Ondol Heating)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

온수나방 시스템의 디지틀 가변구조제어 (Digital Variable Structure Control for a Hot Water Heating System)

  • 안병천;장효환
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.65-75
    • /
    • 1996
  • A pilot plant, which is simplified the hot water heating control system of a large scale residential building, is used to investigate the effects of control methods and operating conditions on the system performance and to compare control characteristics. Digital variable structure controller(DVSC) and digital PI controller are implemented to control the speed of the circulating pump for the pilot plant using PC. For the DVSC, a control algorithm is suggested, which using a nonlinear sliding surface and a PID sliding surface outside and inside of output error boundary layer, respectively. Smith predictor algorithm is used for the compensation of long dead time. The suggested DVSC yields improved control performance compared with existing DVSC using linear sliding surface only. the system responses with the suggested DVSC shows good responses without overshoot for various operating conditions and robust under external disturbances compared with digital PI controller.

  • PDF

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by ECT Method

  • Park, Kwang-June;Chun, Yong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.175-180
    • /
    • 1997
  • It has been known that eater-side corrosion of fuel rods in nuclear reactor is accompanied with the metallic loss of wall thickness and hydrogen pickup in the fuel dadding tube. The fuel dad corrosion is one of the major factors to be controlled to maintain the fuel integrity during reactor operation. An oxide later thickness measuring device equipped with ECT probe system was developed by KAERI, and whose performance test was carried out in NDT(Non-destructive Test) hot-cell or PIE(Post Irradiation Examination) Facility. At first, the calibration/performance test was executed for the unirradiated standard specimen rod fabricated with several kinds of plastic thin films whose thickness ore predetermined, and the result of which showed a good precision within 10% of discrepancy. And then, hot test us peformed for the irradiated fuel rod selectively extracted from J44 fuel assembly discharged from Kori Unit-2. The data obtained with this device were compared with the metallographic result obtained from destructive examination in PIEF hot-cell on the same fuel rod to verify the validity of the measurement data.

  • PDF

신선로(열구자탕) 조리법의 역사적 고찰과 전통적 표준조리법의 제시 (The Historical Study and Standard Traditional Cooking Methods of Sinsulro)

  • 한복진
    • 동아시아식생활학회지
    • /
    • 제5권3호
    • /
    • pp.317-337
    • /
    • 1995
  • "Sinsulro(신선로)" is the famous soup of Cho-sun Dynasty Royal Cuisine, and the original food name is "Yulgujatang(열구자탕)". The first record is on [Sumunsasul] (1740) and the origin history related with Hirang-Jung is on [Headongjukji] and [Chosunyorihak]. From the analysis with Royal banquet menu and 16 kinds of old culinary literatures, "Sinsulro" are contained 54 and 70 material items and used variety cooking methods. Soup base of "Sinsulro" is well boiled meat, shank, brisket, stomach and intestine of beef with water, Some of beef is made meatball and seasoned raw meat. Beef marrow and tripes and liver are sauted with egg. Dried abalone and sea cucumber are soaked in water and then cutting slices after well boiled. Sliced white fish fillet are sauted with egg. Egg white and egg yolk made to thin sheet on pan with oil. Dropwort made to one sheet with flour and egg. Radish are boiled with meat soup and other vegetable are cooked with boiled or sauted. Seeds of pinenut, gingko, walnut are used of decorative seasonings. Filling mehtods of the Sinsulro casserole, the first layer is seasoning raw beef meat, 2nd layer is cooked slice of meat and radish, 3rd layer is rectangle pieces of egg sheet and sauted fish and intestines of beef. The top layer is decorated with meatball and naked nuts. After hot soup is poured until top of the materials, buning charcoal put into the center fire place and then served.o the center fire place and then served.

  • PDF

The Effect of High-Salted Mineral Water on Blood Pressure and Sodium Excretion

  • Park Seung Kyu;Lee Hae Jin;Kim Dong Heui;Deung Young Kun;Yang Eun Ju;Lim Soo Jung;Ryang Yong Suk;Kim Hyun Won;Lee Kyu Jae
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.275-279
    • /
    • 2005
  • High-salted mineral water (Daehan Deep Water, Korea) that is pumped up from below the sedimentary rock layer of Dadaepo, Busan, Korea has a composition similar with that of deep sea water. Under the well-being boom, the mineral water is processed for various uses including washing or oral administration. However, high concentrations of various minerals in the mineral water are suspected to affect on the physiology of human body, especially on blood pressure (BP). Here, we examined the effect of Hot Mineral(R), dried powder of the mineral water, on the change of BP. Sprague­Dawley rats were grouped and orally administered $2.5\%$ Hot Mineral(R) (group M), $2.5\%$ NaCl (group S) or normal water (group C). Excreted urine was collected in metabolic cage for 24 hours. The systolic blood pressure (SBP) of the group S was remarkably increased (P<0.005) compared with that of the group M and the group C, which showed little changes of the SBP during 2 weeks. While average daily sodium intake were 0.32 mg in the group C, 6.64 mg in the group M and 4.07 mg in the group S, average daily sodium excretion were 11.37 mg, 53.70 mg and 7.75 mg, respectively. These results indicate that the sodium excretion in the group M was much higher than the other two groups. In this study, we suppose that the plenty amount of minerals such as calcium, potassium and magnesium in Hot Mineral? have an effect not to increase the SBP and to prompt sodium excretion out of the body. Therefore, these results suggest that oral administration of appropriate amount of Hot Mineral(R) for limited period does not induce increased SBP.

  • PDF