• Title/Summary/Keyword: Hospital management system

Search Result 1,537, Processing Time 0.031 seconds

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

Clinical Study of Vascular Injuries (혈관 손상의 임상적 고찰)

  • Chung, Sung-Woon;Kim, Young-Kyu
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.480-484
    • /
    • 2007
  • Background: Major vascular injuries can jeopardize a patient's life or imperil limb survival. We performed this study to establish an optimal management plan for vascular injuries. Material and Method: We retrospectively reviewed 26 cases of vascular injury that were treated at Pusan National University Hospital from May, 1999 to September, 2004. The age and sex distribution, the locations and causes of vascular injury, the diagnostic tools, the degree of injuries, clinical manifestations, the treatment modality and complications were reviewed. Result: The mean age was 39.5 years (range: $12{\sim}86$) and the male to female ratio was 22 : 4. The injuries were in 6 descending thoracic aortas, 4 femoral arteries, 4 popliteal veins and so on. The causes of injury were iatrogenic in 8 cases, traffic accident in 7, stab injury in 6 and industrial accident in 5. The most commonly used diagnostic tools were CT and angiography. The degrees of arterial injury were pseudoaneurysm in 10 cases, partial severance in 5, complete severance in 3 and thrombosis in 3. The degrees of venous injury were partial severance in 6 cases, complete severance in 2 and arteriovenous fistula in 2. The clinical manifestations were absence of pulse in 8 cases, coldness in 7, chest pain in 6, swelling in 5, bleeding in 5 and so on. The most frequently used type of revascularization was graft interposition in 11 cases. Two arteriovenous fistulae were repaired by endovascular procedure. There was one case of mortality due to multi-organ failure after hemorrhagic shock, There were three major amputations, and two of them were due to delayed diagnosis and treatment. Conclusion: A system for the early diagnosis and treatment is essential for improving limb salvage and patient mortality. As a consequence of the widespread application of endovascular procedures, the incidence of iatrogenic injuries has recently increased. Educating physicians is important for the prevention of iatrogenic injury. Easy communication and cooperation for earlier involvement of a vascular surgeon is also an important factor.

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

Development of a Home-based Nursing Intervention, Mothering Program for Low-Birth-Weight Infants (저체중출생아를 위한 가정간호형 모성역할중재 프로그램 개발과 그 효과에 대한 연구)

  • Han, Kyung-Ja
    • Journal of Home Health Care Nursing
    • /
    • v.8 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • The purpose of this study was to develop a parenting intervention program and determine the efficacy of the program with low-birth weight infants and their mothers. Nine dyads for the experimental group and twelve dyads for the control group discharged from the Neonatal Intensive Care Unit of a University Hospital in Seoul were recruited for the study. For the intervention group, programmed education and support which focused on the maternal sensitivity of the infant's behavior. rearing environment. motherinfant interaction and infant care were given to each subject. Individual counseling and home visits were provided at discharge, one week after discharge. and one and three months of corrected age in every infant. Structured questionaires were administered and feeding interactions were videotaped and coded by a blinded certified observer. A Quasi-experimental design was conducted for this study. Postpartum depression, maternal self esteem. infant care burden, HOME. mother-infant interaction, and infant development were measured. Results were in favor of the intervention versus the control group. On the Beck depression inventory, intervention mothers showed decreasing trends in depressive symptom vs control mothers although, there were statistically no significant differences between the two groups at each time. The mean score of experimental group was 11.55(mild depression state) at discharge and became 8,6(normal state) at 1 month of corrected age. On the other hand, the mean score of the control group was 13.92(mild depression state) at discharge and became 14.0. Maternal self esteem in both groups improved over time. Infant care burden in both groups was also shown to increase over time. There was a significant difference between the two groups in HOME(p=.0340) at 3 months of corrected age. HOME scores of the experimental group and the control's were 31.10 and 25.58, respectively. Mothers' emotional and language responses were significantly high in the intervention group compared with the control group(p=.0155). Intervention group (53.33) showed a significantly high quality of motherinfant interaction compared with the in control group (42.80)(p =.0340). Intervention group mothers appeared have a better quality of mother-infant interaction behaviors. On the other hand, there was no statistical difference in the infant part between groups. Intervention group infants had higher trends in a general developmental quotient: although, there was no statistical difference between groups. The general developmental quotient of intervention infants was 102.56 and control's was 91.28. However, the developmental quotient of the domain of 'individuality-sociality' was higher in the intervention group infants compared with the control's(p=.0155). The concerns identified by parents revealed two domains of an infants' health management -knowledge and skills in caregiving of lowbirthweight-infants, characteristics of lowbirthweight infants, identifying a developmental milestone, coping with emergency situations and relaxation strategies of mothers from the infant care burden. Interview data with the mothers of low-birth weight infants can be used to develop intervention program contents. Limited intervention time and frequency due to time and cost limitations of this study should be modified. The intervention should be continuously implemented when low-birth weight infants become three years old. An NNNS demonstration appeared to be a very effective intervention for the mothers to improve the quality of mother-infant interactions. Therefore intervening in the mothers of low-birth weight infants as early after delivery as possible is desirable. This study has shown that home visit interventions are worthwhile for mothers only beyond the approach as an essential factor in ability of facilitating a growth fostering environment. In conclusion. the intervention program of this study was very effective in enhancing the parenting for the mothers of low-birth weight infants, resulting in health promotion of low-birth weight infants. The home-visit outreach intervention program of this study will contribute to the health delivery system in this country where there is a lack of continuous follow-up programs for low-birth weight infants after discharge from NICU, if it is activated as part of the home visit programs in community health systems.

  • PDF

The Effects of Massage and Static Stretching on Cervical Range of Motion in Their 20s of Normal Adult (마사지 및 정적 스트레칭이 20대 정상 성인의 경부 관절가동범위에 미치는 효과)

  • Kwon, Won-An;Kim, Dong-Dae;Lee, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4346-4353
    • /
    • 2010
  • The purpose of this study was to estimate the cervical range of motion and the effects of massage and static stretching in their 20s of normal adult. One hundred participants(massage=50, stretching=50) with no musculoskeletal and nervous system problems volunteered for this study. Massage and static stretching were applied to sternocleidomstoid, scalenes, trapezius, semispinalis, splenius, suboccipital, multifidi and rotatores. Both groups received intervention for 3 times in a week. The time the intervention was applied was for 10minutes. Effleurage, petrissage and stripping technique was applied to massage group and static stretching technique was applied to stretching group. The cervical range of motion (CROM) instrument was used to measure eight cervical motions (suboccipital flexion, suboccipital extension, neck flexion and extension, and left and right lateral flexion, left and right rotation). As a result of making a statistical analysis of the data, the following findings were given: First, normal cervical range of motion revealed; suboccipital flexion($2.39^{\circ}$) and extension($38.36^{\circ}$), flexion($54.11^{\circ}$) and extension($69.39^{\circ}$), lateral flexion on left($43.50^{\circ}$) and right($41.28^{\circ}$), rotation on left($66.39^{\circ}$) and right($65.94^{\circ}$) in male and suboccipital flexion($5.14^{\circ}$) and extension($36.47^{\circ}$), flexion($55.92^{\circ}$) and extension($71.22^{\circ}$), lateral flexion on left($43.34^{\circ}$) and right($41.06^{\circ}$), rotation on left($69.38^{\circ}$) and right($68.63^{\circ}$) in female. Second, women had greater range of motions than men in suboccipital flexion, left and right rotation(p<0.05). Third, it showed significantly increasing cervical range of motion in all directions within groups following treatments but not between groups(p<0.05). Our results suggest that massage and static stretching are an appropriate intervention to increase cervical range of motion by muscle relaxation and stretching and may be provided a basis for future studies investigating the cervical range of motion.

The Jurisdictional Precedent Analysis of Medical Dispute in Dental Field (치과임상영역에서 발생된 의료분쟁의 판례분석)

  • Kwon, Byung-Ki;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.283-296
    • /
    • 2006
  • Along with the development of scientific technologies, health care has been growing remarkably, and as the social life quality improves with increasing interest in health, the demand for medical service is rapidly increasing. However, medical accident and medical dispute also are rapidly increasing due to various factors such as, increasing sense of people's right, lack of understanding in the nature of medical practice, over expectation on medical technique, commercialize medical supply system, moral degeneracy and unawareness of medical jurisprudence by doctors, widespread trend of mutual distrust, and lack of systematized device for solution of medical dispute. This study analysed 30 cases of civil suit in the year between 1994 to 2004, which were selected among the medical dispute cases in dental field with the judgement collected from organizations related to dentistry and department of oral medicine, Yonsei university dental hospital. The following results were drawn from the analyses: 1. The distribution of year showed rapid increase of medical dispute after the year 2000. 2. In the types of medical dispute, suit associated with tooth extraction took 36.7% of all. 3. As for the cause of medical dispute, uncomfortable feeling and dissatisfaction with the treatment showed 36.7%, death and permanent damage showed 16.7% each. 4. Winning the suit, compulsory mediation and recommendation for settlement took 60.0% of judgement result for the plaintiff. 5. For the type of medical organization in relation to medical dispute, 60.0% was found to be the private dental clinics, and 30.0% was university dental hospitals. 6. For the level of trial, dispute that progressed above 2 or 3 trials was of 30.0%. 7. For the amount of claim for damage, the claim amounting between 50 million to 100 million won was of 36.7%, and that of more than 100 million won was 13.3%, and in case of the judgement amount, the amount ranging from 10 million to 30 million won was of 40.0%, and that of more than 100 million won was of 6.7%. 8. For the number of dentist involved in the suit, 26.7% was of 2 or more dentists. 9. For the amount of time spent until the judgement, 46.7% took 11 to 20 months, and 36.7% took 21 to 30 months. 10. For medical malpractice, 46.7% was judged to be guilty, and 70% of the cases had undergone medical judgement or verification of the case by specialists during the process of the suit. 11. In the lost cases of doctors(18 cases), 72.2% was due to violence of carefulness in practice and 16.7% was due to missing of explanation to patient. Medical disputes occurring in the field of dentistry are usually of relatively less risky cases. Hence, the importance of explanation to patient is emphasized, and since the levels of patient satisfaction are subjective, improvement of the relationship between the patient and the dentist and recovery of autonomy within the group dentist are essential in addition to the reduction of technical malpractice. Moreover, management measure against the medical dispute should be set up through complement of the current doctors and hospitals medical malpractice insurance which is being conducted irrationally, and establishment of system in which education as well as consultation for medical disputes lead by the group of dental clinicians and academic scholars are accessible.