• Title/Summary/Keyword: Hospital design

Search Result 2,879, Processing Time 0.032 seconds

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing (적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교)

  • Kim, Hyo-Seong;Jung, Ji-Hye;Bae, Ji-Myung;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.177-184
    • /
    • 2020
  • Purpose: The purpose of this study was to compare and evaluate the tensile bond strength of chairside reline resin to denture base resin fabricated by different methods (subtractive manufacturing, additive manufacturing, and conventional heat-curing). Materials and methods: Denture base specimens were fabricated as cuboid specimens with a width of 25 mm × length 25 mm × height 3 mm by subtractive manufacturing (VITA VIONIC BASE), additive manufacturing (NextDent Base) and conventional heat-curing (Lucitone 199). After storing the specimens in distilled water at 37℃ for 30 days and drying them, they were relined with polyethyl methacrylate (PEMA) chairside reline resin (REBASE II Normal). The subtractive and additive manufacturing groups were set as the experimental group, and the heat-curing group was set as the control group. Ten specimens were prepared for each group. After storing all bound specimens in distilled water at 37℃ for 24 hours, the tensile bond strength between denture bases and chairside reline resin was measured by a universal testing machine at a crosshead speed of 10 mm/min. The fracture pattern of each specimen was analyzed and classified into adhesive failure, cohesive failure, and mixed failure. Tensile bond strength, according to the fabrication method, was analyzed by 1-way ANOVA and Bonferroni's method (α=.05). Results: Mean tensile bond strength of the heat-curing group (2.45 ± 0.39 MPa) and subtractive manufacturing group (2.33 ± 0.39 MPa) had no significant difference (P>.999). The additive manufacturing group showed significantly lower tensile bond strength (1.23 ± 0.36 MPa) compared to the other groups (P<.001). Most specimens of heat-curing and subtractive manufacturing groups had mixed failure, but mixed failure and adhesive failure showed the same frequency in additive manufacturing group. Conclusion: The mean tensile bond strength of the subtractive manufacturing group was not significantly different from the heat-curing group. The additive manufacturing group showed significantly lower mean tensile bond strength than the other two groups.

The Change and Relationship between Maternal Role Strain and Husband's Support in First-time Mothers with regard to their Employment Status (취업유무에 따른 초산모의 배우자 지지와 역할긴장간의 관계 및 변화)

  • Koh, Hyo-Jung
    • Women's Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.5-35
    • /
    • 1998
  • This study attempted to determine the relation between the maternal role strain and their husbands' support in employed and nonemployed first-time mothers, and how it changed over time. A descriptive, longitudinal and comparative study design was conducted to collect and analyzed the data at three times(at 3-4days, at 4-6wks and at 3-month postpartum) regarding the change of maternal role strain and their husbands' support in employed and nonemployed first-time mothers. The subjects were 133 first-time mothers who delivered vaginally at K university hospital in Deagu, Korea from Dec., 1994 to Oct., 1995. Among these 58 were employed and 75 were nonemployed first-time mothers. This instruments used to data collection in this study were by Hobbs(1968 : The Difficulty Index for First-time Parents), Staffensmeier(1982: Transition Difficulty Measure), Tayer(1976: Emotional Support from Husband), Lee, Hae Kyoung(1992 : Physical Support from Husband). The analysis of data was done with SAS/PC program which included percentage, $x^2$-test, Pearson correlation, Repeated Measure ANOVA, Time Contrast Analysis and t-test. The results were as follows : 1. There was a significant negative correlation only at 3-4days(r=-.19, P=.0265) and at 4-6wks postpartum(r=-.18, P=.0392) between maternal role strain and husband's support of the first-time mothers. Thus, the more support from husband, the less maternal role strains the first-time mothers felt. Therefore, the 1st hypothesis that "the more husband's support the first-time mother felt at all the time of testing, the less maternal role strains they got" was partially supported at 3-days and 4-6 weeks postpartum. There was no correlation between maternal role strain and t husband's support of the employed first-time mothers at al testing times(at 3-4days postpartum : r=-.95, P=.9548, at 4-6wks postpartum : r=-.0960, P=.4733 and at 3-month postpartum : r=-.05, P=7306). On the contrary, the unemployed first-time mothers felt less maternal role strain when they received more support from their husband at 3-4 days postpartum(r=-.31, P=.0073) and at 4-6wks postpartum(r=-.23, P=.0490). 2. There was no difference of maternal role strain between two groups with regards to employment status(F=.97, P=.3270). But the maternal role strains of two groups were changed differently each other over time(F=3.89, P=.00234). Therefore, the 2nd hypothesis that "there was the difference in the maternal role strains with regard to employment status and over time" was rejected. 3. There was no difference in husband's support between the employed and the nonemployed first-time mothers(F=3.06, P=.0826). But there was a significant interaction between employment status and over time(F=3.64, P=.0267), so the support from husband of the employed and the unemployed first-time mothers was changed differently each other over time. The support from husband of the employed first-time mothers was lowered significantly and continuously at 4-6wks (F=5.20, P=.0263) and at 3-month postpartum(F=6.47, P=.0137) than at 3-4 days postpartum. On the contrary, there was no difference in change of husband's support of the employed first-time mothers between the 3-4 days and the 4-6wks postpartum(F=1.70, P=.1962) and between the 3-4 days and the 3-month postpartum(F=.21, P=.6513). Mean husband's support of the nonemployed first-time mothers was raised at 4-6wks postpartum than at 3-4 days postpartum but lowed at 3-month postpartum. The support form husband of both groups was tending downwards at 3-month postpartum than at 4-6wks postpartum, but the one between two groups was changed differently each other over time. The husband's support of the employed first-time mothers(M${\pm}$SD=64. 26${\pm}$8.63) was higher than the one of the nonemployed first-time mothers(M${\pm}$SD=59.16${\pm}$11.11) (t=-2.98, P=.0035), so the 3rd hypothesis that "there was the difference in the husband's support with regard to employment status and over time" was supported. On the basis of these conclusions, the following suggestion is proposed. This study examined the change and relationship between maternal role strain and husband's support in the employed and the nonemployed first-time mothers. So the further study regarding the comparison between the employed and the nonemployed multiparas is necessary.

  • PDF

Analysis of Intervention in Activities of Daily Living for Stroke Patients in Korea: Focusing on Single-Subject Research Design (국내 뇌졸중 환자를 대상으로 한 일상생활활동 중재 연구 분석: 단일대상연구 설계를 중심으로)

  • Sung, Ji-Young;Choi, Yoo-Im
    • Therapeutic Science for Rehabilitation
    • /
    • v.13 no.1
    • /
    • pp.9-21
    • /
    • 2024
  • Objective : The purpose of this study was to confirm the characteristics and quality of a single-subject research that conducted interventions to improve activities of daily living (ADL) in stroke patients. Methods : 'Stroke,' 'activities of daily living,' and 'single-subject studies' were searched as keywords among papers published in the last 15 years between 2009 and 2023 among Research Information Sharing Service, DBpia, and e-articles. A total of nine papers were examined for the characteristics and quality before analysis. Results : The independent variables applied to improve ADL included constraint-induced therapy, mental practice for performing functional activities, virtual reality-based task training, subjective postural vertical training without visual feedback, bilateral upper limb movement, core stability training program, traditional occupational therapy and neurocognitive rehabilitation, smooth pursuit eye movement, neck muscle vibration, and occupation-based community rehabilitation. Assessment of Motor and Process Skills was the most common evaluation tool for measuring dependent variables, with four articles, and Modified Barthel Index and Canadian Occupational Performance Measure were two articles each. As a result of confirming the qualitative level of the analyzed papers, out of a total of nine studies, seven studies were at a high level, two at a moderate level, and none were at a low level. Conclusion : Various types of rehabilitation treatments have been actively applied as intervention methods to improve the daily life activities of stroke patients; the quality level of single-subject studies applying ADL interventions was reliable.

The Effect of Deep Breathing Methods on Pulmonary Ventilatory Function of Patients Who experiened Upper-abdominal surgery (심호흡 방법에 따른 상복부 수술환자의 폐 환기능에 미치는 효과)

  • Hwang Jin-Hee;Park Hyung-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.2
    • /
    • pp.129-147
    • /
    • 1994
  • The purpose of this study was to examine the effect of deep breathing exercise with Incentive Spirometer on the pulmonary ventilatory function of postoperative patients. This experiment was operated by quasi-experimental design which was compared pre-experimental measures with post-experimental ones. The subject of this study was 46 inpatients who were scheduled for elective upper abdominal surgery under the general anesthesia in P National University Hospital in Pusan and classified into the experimental group(23 patients) and control group(23 patients) by using Incentive Spirometer or unusing one. The data were collected from November, 1, 1993, to December, 31, 1993. The effects of the deep breathing exercise on the pulmonary ventilatory function were compared between experimental group who were recieved deep breathing exercise with Incentive Spirometer and control group who were recieved same method without Incentive Spirometer. The Forced Vital Capacity (FVC) and the First Second Forced Expiratory Volume ($FEV_1$) were represented as index of the pulmonary ventilatory function and those were measured by Vitalograph Compact. The collected data were analysed by SPSS/PC+ (percentage, average, standard deviation, chi-square test, t-test, and ANOVA). The results were as follow : (1) The $FVC_s$ of the experimental group were significantly increased in course of time, 24, 48, 72 hours after surgery(F=3.530, P=0.035). (2) The $FVC_s$ and $FEV_{1S}$ of the control group were significantly increased in course of time, 24, 48, 72 hours after surgery ($FVC_s$ : F=3.480, P=0.037, $FEV_{1S}$ : F=6. 153, P=0.004). (3) The FVC which was measured at 72 hours after surgery was significantly higher in the experimental group than in the control group(t=2.620, P=0.013). (4) The $FEV_{1s}$ which were measured at 24 and 72 hours after surgery were significantly higher in the experimental group than in the control group(24hr. : t=2.530, P=0.017, 72hr. : t=2.540, P=0.016). (5) Among general characteristics, sex was significant variable which influenced to effect of pulmonary ventilatory function. In conclusion, this study showed that the deep breathing exercise with Incentive Spirometer was more effective to recover the pulmonary ventilatory function after surgery than the deep breathing exercise without Incentive Spirometer.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

An experimental study on the impact of an agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers and enhance their self-confidence and satisfaction in maternal role performance (산욕초기 초산모의 간호목표달성방번 합의가 어머니 역할수행에 대한 자신감 및 만족도에 미치는 영향에 관한 실험적 연구)

  • 이영은
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.1
    • /
    • pp.81-115
    • /
    • 1992
  • The problem addressed by this study was to determine the effect of nurse - patient agreement on the means to achieve nursing goals in the early postpartum period of primiparous mothers. It was hypothesized that the experimental treatment would result in hegher self-confidence and satisfaction in maternal role performance. This purpose was to contribute to the planning of nursing care to enhance self- confidence and satisfaction in maternal role performance and to the development of relevant nursing theory. Especially, the early postpartum period is crucial toward in recovery from childbirth and attainment of the maternal role. Maternal role attaintment is a complex social and cognitive process of stimulus -response accomplished by learning. Most women attain the maternal role sucessfully. But, some primiparous mothers experience difficultites in attainment of the maternal role due to lack of experience and knowledge. Self-confidence and satisfaction in maternal role performance are important factors in attainment and adjustment to the maternal role (Mercer, 1981a, 1981b ; Lederman, Weigarten, and Lederman, 1981 :Bobak and Jensen, 1985). Nursing is defined as behaviors of nurses add patients that attain nursing goals through action, reaction, interaction, and transaction. For attainment of nursing goals, active participating transactions must occur by agreement on the means to achieve those goals through nurse -patient mutual goal setting and establishment of their active relationships(King, 1981, Ha, 1977). Based on King's theory of goal attainment (1981), this stuy was planned as a non-equivalent control group, non -synchronized quasi -experimental design using agreement on the means to achieve nursing goals in early postpartum as the experimental treatment. The data were collected from July 20 to Sep. 1, 1991 by questionnaires with 60 primiparous mothers planing to breast feed after normal deliveries at W hospital in Pusan, Korea. The subjects were divided into a control group(conventional group) -those admitted from July 20 to Aug. 12, and an experimental group(agreement group) - those admitted from Aug. 13 to Sep. 1. The instument for agreement on the means to nursing goals in the early postpartum period included five steps - identification of disturbances of problems through action, reaction, and interaction with primiparous mothers : mutual early postpartal nursing goal setting : exploration of the means to achieve goals ; agreement on the means (self- care, ealry maternal -infant contact, performance of mothering behavior, and communicating about the infant's behavior and health condition) : implementation of the means. This instrument was developed on the basis of King's elements that lead to transactions in nurse-patient interactions. Lederman et al's (1981) scale for Confidence in ability to cope with tasks of motherhood and Lederman et al's(1981) scale for Mother's satisfaction with motherhood and infant care were used to measure self-confidence and satisfaction in maternal role performance ·with the subjects immediately after admission and on the day of discharge. Self-care performance in the experimental group was measured by self -evaluation tool developed by the investigator from the literature concerned. The tools to measure Pelf-confidence and satisfaction in maternal role performance, and the tool to measure self-evaluation of self-care performance were tested for internal reliability. Cronbach's Alphas were 0.94, 0.94, and 0.63. The data were analysed by using in S.P.S.S. computerized program and included percentage, x²-test, t-test, ANOVA, and Pearson Correlation Coefficient. The conclusions obtained from this study are summerized as follows : 1. The degree of self-confidence in maternal role performance of the total subjects group measured before the experimental treatment was above average with a mean score of 2.77(range 2.14-3.64). Out of 14 items, those with relatively high mean scores were ‘I would like to be a better mother than I am’(3.95), and ‘I have my doubts about whether I am a good mother’(2.87). Those with low mean scores were ‘I know that my baby wants most of the times’(2.28), ‘When the baby cries, I can tell what she /he wants’(2.37), and ‘I have confidence in my ability to care for the baby’(2;50). That is, the self - confidence of Primiparous mothers was considerably high in mothering, but rather low in activities concerning the infant care and understanding of the infant behavior. The degree of satisfaction in maternal role performance of the total subjects group measured before the experimental treatment was high with a mean score of 3.18(range 1.92-3.92). Out of 13 items, those with relatively high mean scores were ‘I am glad 1 had this baby now’(3.75), ‘I play with the baby between feedings when s/he is awake and quiet’(3.67), and ‘I enjoy being a mother’(3.27). Those with low mean scores were ‘I am upset about having too many responsibilities as a mother’(2.78), ‘It bothers me to get up for the baby at night’(2.82), and ‘I get annoyed if the baby frequently interrupts my activities’.(2.82), That is, the satisfaction of primiparous mothers was considerably high in mothering and infant care, but rather low in restraints in time or on the mother's self accomplishment and development. 2. Agreement on the means to achieve nursing goals in the early postpartum period included process of mutual goal setting, exploration of the means to achieve goals, and ahreement in concert means to achieve goals based on the mothers' condition, concerns, self-perception of the nurse - patient interactions. In the process of agreement, there was agreement that the means to achieve goals should be through trust and establishment of active relationships with the nurse through identification of problems according to planned nursing goals and active interaction, such as explanations, teaching, changing of opinions, acceptance or rejection of explanations, and proposing of questions. Therefore agreement on the means to achieve nursing goals in the early postpartum period appears to be an effective nursing intervention for primiparous mothers. 3. The degree of self- confidence in maternal role performance of the exprimental group was higher than that of the control group(t=3.95, p<0.01). Out of 14 items, those with higher score in the experimental group were ‘I would like to be a better mother than I am’(t=1.93, p<0.05), ‘I know that my baby wants most of the times’(t=2.75, p<0.01), ‘When the baby cries, 1 can tell what she/he wants’(t=2.10, p<0.05), ‘I have confidence in my ability to care for the baby’(t=3.72, p<0.01), ‘I trust my own judement in deciding how to care for the baby’(t=1.96, p<0.05), ‘I feel that I know my baby and what to do for him /her’(t=2.44, p<0.01), ‘I am concerned about being able to meet the baby's needs’(t=2.87, p<0.01), ‘I know what my baby likes and dislikes’(t=3.26, p<0.01), ‘I don't know to care for the baby as well as I should’(t=2.07, p<0.05), and ‘I am unsure about whether I give enough attention to the baby’(t=3.04, p<0.01), That is, the degree of self-confidence in mothering, activities concerning infant care, and understanding of infant behavior of the experimental group was higher than that of the control group. Therefore, the first hypothesis, that the degree of self-confidence in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=3.95, p<0.01). 4. The degree of satisfaction in the maternal role performance of the exprimental group was higer than that or the control group(t=2.31, p<0.05). Out of 13 items, those with higher score in the experimental group were ‘I am glad I had this baby now’(t=2.29, p<0.05), ‘I enjoy taking care of the baby’(t=2.4g, p<0.01), ‘It is boring for me to care for the baby and do the same thing over and over’(t=2.87, P<0.01), ‘I am unhappy with the amount of time I have for activities other than childcare’(t=2.51, p<0.01), and ‘When bathing and diapering the baby, I would like to be doing something else’(t=2.43, p<0.01). That is, the degree of satisfaction in mothering, infant care, and restraints in time of on the mother's self accomplishment and development in the experimental group was higher than that of the control group. Therefore, the second hypothesis, that the degree of satisfaction in maternal role performance of the experimental group would be higher than that of the control group, was supported(t=2.31, p<0.05). 5. The third hypothesis, that the higher the degree of satisfaction in materenal role performance, the higher the degree of self-confidence in materenal role performance in the experimental group, was supported (r=0.57, p<0.01)

  • PDF

A Study Concerning Health Needs in Rural Korea (농촌(農村) 주민(住民)들의 의료필요도(醫療必要度)에 관(關)한 연구(硏究))

  • Lee, Sung-Kwan;Kim, Doo-Hie;Jung, Jong-Hak;Chunge, Keuk-Soo;Park, Sang-Bin;Choy, Chung-Hun;Heng, Sun-Ho;Rah, Jin-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.1
    • /
    • pp.29-94
    • /
    • 1974
  • Today most developed countries provide modern medical care for most of the population. The rural area is the more neglected area in the medical and health field. In public health, the philosophy is that medical care for in maintenance of health is a basic right of man; it should not be discriminated against racial, environmental or financial situations. The deficiency of the medical care system, cultural bias, economic development, and ignorance of the residents about health care brought about the shortage of medical personnel and facilities on the rural areas. Moreover, medical students and physicians have been taught less about rural health care than about urban health care. Medical care, therefore, is insufficient in terms of health care personnel/and facilities in rural areas. Under such a situation, there is growing concern about the health problems among the rural population. The findings presented in this report are useful measures of the major health problems and even more important, as a guide to planning for improved medical care systems. It is hoped that findings from this study will be useful to those responsible for improving the delivery of health service for the rural population. Objectives: -to determine the health status of the residents in the rural areas. -to assess the rural population's needs in terms of health and medical care. -to make recommendations concerning improvement in the delivery of health and medical care for the rural population. Procedures: For the sampling design, the ideal would be to sample according to the proportion of the composition age-groups. As the health problems would be different by group, the sample was divided into 10 different age-groups. If the sample were allocated by proportion of composition of each age group, some age groups would be too small to estimate the health problem. The sample size of each age-group population was 100 people/age-groups. Personal interviews were conducted by specially trained medical students. The interviews dealt at length with current health status, medical care problems, utilization of medical services, medical cost paid for medical care and attitudes toward health. In addition, more information was gained from the public health field, including environmental sanitation, maternal and child health, family planning, tuberculosis control, and dental health. The sample Sample size was one fourth of total population: 1,438 The aged 10-14 years showed the largest number of 254 and the aged under one year was the smallest number of 81. Participation in examination Examination sessions usually were held in the morning every Tuesday, Wenesday, and Thursday for 3 hours at each session at the Namchun Health station. In general, the rate of participation in medical examination was low especially in ages between 10-19 years old. The highest rate of participation among are groups was the under one year age-group by 100 percent. The lowest use rate as low as 3% of those in the age-groups 10-19 years who are attending junior and senior high school in Taegu city so the time was not convenient for them to recieve examinations. Among the over 20 years old group, the rate of participation of female was higher than that of males. The results are as follows: A. Publie health problems Population: The number of pre-school age group who required child health was 724, among them infants numbered 96. Number of eligible women aged 15-44 years was 1,279, and women with husband who need maternal health numbered 700. The age-group of 65 years or older was 201 needed more health care and 65 of them had disabilities. (Table 2). Environmental sanitation: Seventy-nine percent of the residents relied upon well water as a primary source of dringking water. Ninety-three percent of the drinking water supply was rated as unfited quality for drinking. More than 90% of latrines were unhygienic, in structure design and sanitation (Table 15). Maternal and child health: Maternal health Average number of pregnancies of eligible women was 4 times. There was almost no pre- and post-natal care. Pregnancy wastage Still births was 33 per 1,000 live births. Spontaneous abortion was 156 per 1,000 live births. Induced abortion was 137 per 1,000 live births. Delivery condition More than 90 percent of deliveries were conducted at home. Attendants at last delivery were laymen by 76% and delivery without attendants was 14%. The rate of non-sterilized scissors as an instrument used to cut the umbilical cord was as high as 54% and of sickles was 14%. The rate of difficult delivery counted for 3%. Maternal death rate estimates about 35 per 10,000 live births. Child health Consultation rate for child health was almost non existant. In general, vaccination rate of children was low; vaccination rates for children aged 0-5 years with BCG and small pox were 34 and 28 percent respectively. The rate of vaccination with DPT and Polio were 23 and 25% respectively but the rate of the complete three injections were as low as 5 and 3% respectively. The number of dead children was 280 per 1,000 living children. Infants death rate was 45 per 1,000 live births (Table 16), Family planning: Approval rate of married women for family planning was as high as 86%. The rate of experiences of contraception in the past was 51%. The current rate of contraception was 37%. Willingness to use contraception in the future was as high as 86% (Table 17). Tuberculosis control: Number of registration patients at the health center currently was 25. The number indicates one eighth of estimate number of tuberculosis in the area. Number of discharged cases in the past accounted for 79 which showed 50% of active cases when discharged time. Rate of complete treatment among reasons of discharge in the past as low as 28%. There needs to be a follow up observation of the discharged cases (Table 18). Dental problems: More than 50% of the total population have at least one or more dental problems. (Table 19) B. Medical care problems Incidence rate: 1. In one month Incidence rate of medical care problems during one month was 19.6 percent. Among these health problems which required rest at home were 11.8 percent. The estimated number of patients in the total population is 1,206. The health problems reported most frequently in interviews during one month are: GI trouble, respiratory disease, neuralgia, skin disease, and communicable disease-in that order, The rate of health problems by age groups was highest in the 1-4 age group and in the 60 years or over age group, the lowest rate was the 10-14 year age group. In general, 0-29 year age group except the 1-4 year age group was low incidence rate. After 30 years old the rate of health problems increases gradually with aging. Eighty-three percent of health problems that occured during one month were solved by primary medical care procedures. Seventeen percent of health problems needed secondary care. Days rested at home because of illness during one month were 0.7 days per interviewee and 8days per patient and it accounts for 2,161 days for the total productive population in the area. (Table 20) 2. In a year The incidence rate of medical care problems during a year was 74.8%, among them health problems which required rest at home was 37 percent. Estimated number of patients in the total population during a year was 4,600. The health problems that occured most frequently among the interviewees during a year were: Cold (30%), GI trouble (18), respiratory disease (11), anemia (10), diarrhea (10), neuralgia (10), parasite disease (9), ENT (7), skin (7), headache (7), trauma (4), communicable disease (3), and circulatory disease (3) -in that order. The rate of health problems by age groups was highest in the infants group, thereafter the rate decreased gradually until the age 15-19 year age group which showed the lowest, and then the rate increased gradually with aging. Eighty-seven percent of health problems during a year were solved by primary medical care. Thirteen percent of them needed secondary medical care procedures. Days rested at home because of illness during a year were 16 days per interviewee and 44 days per patient and it accounted for 57,335 days lost among productive age group in the area (Table 21). Among those given medical examination, the conditions observed most frequently were respiratory disease, GI trouble, parasite disease, neuralgia, skin disease, trauma, tuberculosis, anemia, chronic obstructive lung disease, eye disorders-in that order (Table 22). The main health problems required secondary medical care are as fellows: (previous page). Utilization of medical care (treatment) The rate of treatment by various medical facilities for all health problems during one month was 73 percent. The rate of receiving of medical care of those who have health problems which required rest at home was 52% while the rate of those who have health problems which did not required rest was 61 percent (Table 23). The rate of receiving of medical care for all health problems during a year was 67 percent. The rate of receiving of medical care of those who have health problems which required rest at home was 82 percent while the rate of those who have health problems which did not required rest was as low as 53 percent (Table 24). Types of medical facilitied used were as follows: Hospital and clinics: 32-35% Herb clinics: 9-10% Drugstore: 53-58% Hospitalization Rate of hospitalization was 1.7% and the estimate number of hospitalizations among the total population during a year will be 107 persons (Table 25). Medical cost: Average medical cost per person during one month and a year were 171 and 2,800 won respectively. Average medical cost per patient during one month and a year were 1,109 and 3,740 won respectively. Average cost per household during a year was 15,800 won (Table 26, 27). Solution measures for health and medical care problems in rural area: A. Health problems which could be solved by paramedical workers such as nurses, midwives and aid nurses etc. are as follows: 1. Improvement of environmental sanitation 2. MCH except medical care problems 3. Family planning except surgical intervention 4. Tuberculosis control except diagnosis and prescription 5. Dental care except operational intervention 6. Health education for residents for improvement of utilization of medical facilities and early diagnosis etc. B. Medical care problems 1. Eighty-five percent of health problems could be solved by primary care procedures by general practitioners. 2. Fifteen percent of health problems need secondary medical procedures by a specialist. C. Medical cost Concidering the economic situation in rural area the amount of 2,062 won per residents during a year will be burdensome, so financial assistance is needed gorvernment to solve health and medical care problems for rural people.

  • PDF