• Title/Summary/Keyword: Hospital Location

Search Result 1,507, Processing Time 0.039 seconds

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

The Incidence Rate of Lymphadenitis after Bacille Calmette-Guérin (BCG) Vaccination (Bacille Calmette-Guérin (BCG) 백신 접종 후 림프절염의 발생 빈도)

  • Kim, Jaehong;Lee, Kyujin;Kim, Jong-Hyun;Kim, Seong Joon;Lee, Soo Young;Lee, Hye Jin;Cho, Kyung Soon;Kwon, Young Joo;Lee, Byoung Chan;Jo, Sang Min;Ha, Jeong Hun;Lee, Yoon Kyung;Seung, So Jin
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2016
  • Purpose: Bacille Calmette-$Gu{\acute{e}}rin$ (BCG) lymphadenitis is a relatively frequent local adverse reactions after BCG vaccination. Its incidence rate is usually <1%. However, this rate may be different according to BCG strain, vaccination method or skill, etc. In the Republic of Korea, two BCG strains are used: intradermal Danish-1331 or percutaneous Tokyo-172. We surveyed the incidence rates of BCG lymphadenitis. Methods: This survey was performed in total 25 centers (5 general hospitals, 20 private pediatric clinics). Immunized type of BCG strain in study subjects was verified by directly observing the scar. The occurrence of BCG lymphadenitis was asked to their parent. In cases of BCG lymphadenitis, location, diameter size, progression of suppuration, and treatment method were investigated, as well. Results: The total number of study subjects was 3,342. Among these, the subjects suitable for enrollment criteria (total 3,222; Tokyo strain 2,501, Danish strain 721) were analyzed. BCG lymphadenitis regardless of its size developed in each five of subjects per strains, therefore, its incidence rate was 0.20% in Tokyo and 0.69% in Danish strain, respectively (P=0.086). However, when applying the WHO criteria - the development of lymph node swelling with diameter 1.5 cm or more, the incidence rate of BCG lymphadenitis was 0.16% (4 cases) in Tokyo and 0.42% (3 cases) in Danish strain, respectively. Conclusions: The incidence rate of lymphadenitis in two BCG types, percutaneous Tokyo and intradermal Danish strain BCG, is 0.20% and 0.69%, respectively. Both rates are acceptable.

Analysis of Postpneumonectomy Complication without Balanced Chest Bottle (흉관 삽입술 없이 시행한 전폐절제술 후 발생한 합병증에 대한 분석)

  • Kim, Tae-Gyun;Chung, Won-Sang;Kang, Jung-Ho;Kim, Young-Hak;Kim, Hyuck;Jee, Heng-Ok;Lee, Chul-Bum;Ham, Shi-Young
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.290-295
    • /
    • 2002
  • Backgroud: Pneumonectomy carries the possibility of numerous dangerous complications as well as the vast effect the operation itself has on the cardiopulmonary function. Most of operations are done with the insertion of the chest tubes upon completion, but because of the high incidence of pyothorax as its complications, we have tried to analyze and compare the cases without inserting the chest tubes. Material and Method: During a 5 year period from January, 1996 to December 2000, 100 cases, which were operated at the Hanyang University Hospital, were selected using the patient's charts. The age, gender, indication of operation, associated diseases, and operation site(left or right) were classified accordingly and the postoperative complications and mortality were statistically analyzed using the $\chi$ 2-test. After resecting the lung, the intrathoracic pressure was set at -15 ~ -20cm $H_2O$ using the nelaton catheter, and the thoracotomy site was then closed. The gradual collection of the fluid and blood in the thorax of the operated side, as well as the mediastinum location, were observed carefully for 4~5 days postoperatively with the aid of the simple chest x-rays. Result: Of the 100 cases, 16 cases of pulmonary tuberculosis(16%), 81 cases of lung tumor(81%), 2 cases of bronchiectasis(2%), and 1 case of aspergilloma associated bronchiectasis were noted. There were 8 mortality cases(8%), and of the 34 cases(34%), 44 complications were noted. The age, sex, and operation site(left or right) were not statistically significant with the complications. 7 of the 16 cases of pulmonary tuberculosis(44%) and 27 of the 81 cases of lung tumor(33%) had complications, but they were found not to be statistically significant. The increase of the complication rate in the pulmonary tuberculosis patients was 3.86. The evidence of postoperative bleeding was observed in 6 cases with the 3 cases being the pulmonary tuberculosis patients and the 3 cases were others. This shows that the increase in postoperative bleeding in the pulmonary tuberculosis is statistically significant(p=0.019). Of the 100 cases, there were 8 mortality cases(8%), with 5 cases from the 81 cases of the lung tumor group(6.1%), 3 cases from the 16 cases of pulmonary tuberculoses group(18.7%).

Outcome of Tumor Prosthetic Reconstruction in Osteosarcoma Patient (골육종 환자에서 종양 대치물을 이용한 재건술의 치료결과)

  • Kim, Jae-Do;Kim, Cheung-Kue;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.79-86
    • /
    • 2011
  • Purpose: Modular tumor prosthesis is the most popular recontructive modality after resection of malignat tumor in extremity. Complications and survival of tumor prosthesis reconstruction are well-known. however, reports on the long-term outcome of tumor prosthesis in osteosarcoma patientss are scarece. Materials and Methods: In 158 cases as diagnosed as osteosarcoma from feburary 1989 to December 2006 in a single cancer center. We retrospectively reviewd 48 osteosarcoma patients who under went tumor prosthetic reconstruction. Mean follow up preiod was 75.6 months (range; 60 to 179 months). There were 28 males, 20 females and mean age was 22.4 years (range; 11-71). Pathologic subtypes were conventional central osteosarcoma in 46 cases and periosteal in 2 cases. The location of the tumor was proximal tibia (26 cases), distal femor (20 cases), femor diaphysis (1 case), and tibia diaphysis (1 case). In 41 cases built-up-type tumor prosthesis have been used and 7 cases expansion-type tumor prosthesis have been used. We used Musculoskeletal tumor society (MSTS) grading system to asses post operation function, and we analyzed survival rate of patient and tumor prosthesis and complication. Results: The overall survival rate was 77.7% and disease free survival rate was 68.9%. The survival rate of tumor prosthesis was 73%, in last follow up tumor prosthesis has been removed in 12 cases. All of them, 17 complications occurred, which included infection in 16 cases, Periprosthetic Fracture and Loosening of tumor prosthesis in 4 cases, articular instability in 4 cases. MSTS functional score was 74.1% in post operation. Conclusion: In long term follow up result, Primary tumor prosthesis -a reconstruction method after a wide extensional resecion of a bone tumor- can be a effective treatment method in asepect of survival rate, functional assesment and complication.

Application of Patient Safety Indicators using Korean National Hospital Discharge In-depth Injury Survey (퇴원손상심층자료를 이용한 환자안전지표의 적용)

  • Kim, Yoo-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2293-2303
    • /
    • 2013
  • Objective: This study aims to determine whether national patient safety indicators (PSIs) can be calculated. Methods: Using PSI criteria from Organization for Economic Co-Operation and Development (OECD) Health Technical Papers 19 based on the Agency for Healthcare Research and Quality (AHRQ), PSIs were identified in the Korean National Hospital Discharge In-depth Injury Survey (KNHDIIS) database for 875,622 inpatient admissions between 2004 and 2008. Logistic regression was used to estimate factors of variations for PSIs. Results: From 2004 to 2008, 3,084 PSI events of 8 PSIs occurred for over 80 thousands discharges. Rates per 1,000 events for decubitus ulcer (PSI3, 4.88), foreign body left during procedure (PSI5, 0.05), postoperative sepsis (PSI13, 1.32), birth trauma-injury to neonate (PSI17, 7.92) and obstetric trauma-vaginal delivery (PSI18, 32.81) are all identified between ranges from maximum to minimum of OECD rates, respectively. However, rates per 1,000 events for selected infections due to medical care (PSI7, 0.22), postoperative pulmonary embolism or deep vein thrombosis (PSI12, 0.90) and accidental puncture or laceration (PSI15, 0.71) are below the minimum of OECD range. 7 PSIs except PSI 18 showed statistically significant relationship with number of secondary diagnoses. When adjusting patient characteristics, there are statistically significant different rates according to bed size or location of hospitals. Conclusion: This is the first empirical study to identify nationally number of adverse events and PSIs using administrative database. While many factors influencing these results such as quality of data, clinical data and so on are remain, the results indicate opportunities for estimate national statistics for patient safety. Furthermore outcome research such as mortality related to adverse events is needed based on results of this study.

Incidence and magnitude of out-of-pocket payment and factors influencing them in Industrial Accident Compensation Insurance (산재환자의 진료비 본인부담 발생 및 크기와 이에 영향을 미치는 요인)

  • Park, Bo-Hyun;Lee, Tae-Jin;Lim, Wha-Young
    • Health Policy and Management
    • /
    • v.20 no.1
    • /
    • pp.103-124
    • /
    • 2010
  • Objectives: The out-of-pocket payment (OOP) of the Industrial Accident Compensation Insurance (IACI) in Korea was investigated empirically in terms of its incidence, magnitude and factors influencing them. Methods: The subjects were sampled with stratified, randomized methods among medical institutions of which the number of monthly IACI claims exceeded its median as of May 2008. Out of 204 institutions selected, 118 institutions (57.8%) responded to this survey. A total of 24,826 episodes(2,457 inpatient and 22,369 outpatient episodes) were included in this analysis. The incidence and magnitude of OOP of IACI were calculated by characteristics of institution as well as patient. Factors that affected the incidence and magnitude of OOP were investigated through multi-level analysis. Results: The overall incidence of OOP of IACI was 9.9% (25.6% for inpatient and 8.2% for outpatient) and the percentage of OOP among total expenditures was 8.3% on average (7.6% for inpatient and 26.8% for outpatient); 25.2% at traditional oriental medicine hospitals, 9.5% at general hospitals and 2.5% at the industrial-accident-designated medical institutions. The incidence of OOP of IACI was influenced by hospital size, ownership, longer duration of designation (over 5 years) and length of stay. On the other hand, its magnitude was influenced by medium-sized hospital, public hospital, location of large city and length of stay. Extra charges for upper grade room which accommodates less than 4 patients and treatment by specialists were the leading contributors to the magnitude of OOP of IACI. Conclusion: The incidence and magnitude OOP of IACI varied in institution type and were influenced by both institutional and patient's factors. In order to achieve the goal of Industrial Accident Compensation Insurance, appropriate level of compensation, that is, no incidence of OOP, for accident and disease of workers, it is necessary to take measures to reduce incidence and magnitude of OOP.

The Reconstruction with Extracorporeal Irradiated Autograft for Osteosarcoma of Extremities (사지 골육종에서 체외 방사선 조사를 이용한 재건술)

  • Kim, Jae-Do;Lee, Gun-Woo;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: With advances in various treatment modalities, limb salvage surgery has been commonly used in osteosarcoma of extremities. An alternative method for skeletal reconstruction is reimplantation of the tumor bearing bone following extracorporeal irradiation (ECI). We report the long-term results of ECI autograft in aspect of the oncological and functional outcomes, and complications. Materials and Methods: We retrospectively reviewed 31 osteosarcoma patients who underwent reconstruction with ECI between July 1995 and January 2006. There were 24 males and 7 females with a mean age of 24 (7-74 years) and a mean follow-up of 117 months (17-177 months). Twenty-five cases were reconstructed with ECI autograft, 6 cases with ECI autograft-prosthesis composite. The pathologic subtypes were conventional in 29 cases, periosteal in 1 case, and parosteal in 1 case. The most common location of tumor was distal femur (15 cases) followed by humerus (3), proximal fibula (3) and proximal tibia (3). Musculoskeletal Tumor Society (MSTS) score was used for functional evaluation. The overall survival rate, local recurrence, complications were analyzed. Results: The overall survival rate was 80.6% and the disease-free survival rate was 64.5%. Five patients died of distant metastasis. One patient required above-knee amputation due to local recurrence. All of them, twenty-three complications occurred, which included nonunion in 7 cases, deep infection in 5 cases, joint instability in 4 cases, metal failure in 2 cases, Limb-length discrepancy (LLD) in 2 cases, periprosthetic fracture in 1 case, epiphyseal collapse in 1, local recurrence in 1 case. The mean MSTS functional score was 62.5%. Conclusion: Extracorporeal irradiated autograft can be achieved relatively good result in aspect of oncological and functional aspect, but is needed to be additional research about occurring many complications. The reconstruction with ECI after intercalary or fragmentary resection is effective reconstruction in aspect of oncological and functional result, complications.

Post-Infarction Ventricular Septal Rupture : 10 Years of Experience (급성 심근경색증 후 심실중격 결손: 10년 경험)

  • Jung, Yo-Chun;Cho, Kwang-Ree;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.351-355
    • /
    • 2007
  • Background: Postinfarction ventricular septal rupture is associated with mortality as high as $85\sim90%$, if it is treated medically. This report documents our experience with postinfarction ventricular septal rupture that was treated surgically, Material and Method: We retrospectively reviewed the medical records of 11 patients who were operated on due to postinfarction ventricular septal rupture between August 1996 and August 2006. There were 4 men and 7 women, with a mean age of $70{\pm}11$ years (age range: $50\sim84$ years). The location of the rupture was anterior in 7 cases and posterior in 4 cases. The interval between the onset of acute myocardial infarction and the occurrence of the ventricular septal rupture was $2.0{\pm}1.3$ days (range: $1\sim5$ days). Operation was performed at an average of $2.4{\pm}2.7$ days (range: $0\sim8$ days) after the diagnosis of septal rupture. Preoperative intraaortic balloon pump therapy was performed in 10 patients. Result: The infarct exclusion technique was used in all cases. Coronary artery bypass grafting was done in 8 cases, with the mean number of distal anastomosis being $1.0{\pm}0.8$. There was one operative death. In 2 patients, reoperation was performed due to a residual septal defect. The postoperative morbidities were transient atrial fibrillation (n=7), paroxysmal supraventricular tachycardia (n=1), low cardiac output syndrome (n=3), bleeding reoperation (n=2), delayed sternal closure (n=2), acute renal failure (n=2), pneumonia (n=1), intraaortic balloon pump-related thromboembolism (n=1), and transient delirium (n=2). Nine patients have been followed up for a mean of $38{\pm}40$ months except for one follow-up loss. There have been 3 late deaths. At the latest follow-up, all 6 survivors were in a good functional class. Conclusion: We demonstrated satisfactory operative and midterm results with our strategy of preoperative intraaortic balloon pump therapy, early repair of septal rupture by infarct exclusion and combined coronary revascularization.