• Title/Summary/Keyword: Hose reel hydrant

Search Result 4, Processing Time 0.019 seconds

A Comparative study of the performance for hose reel hydrant system and indoor hydrant system (호스릴옥내소화전설비와 옥내소화전설비의 성능 비교 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kim, Joon-Bae;Kang, Tae-Young;Park, Sung-Ock;Han, Jae-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.104-107
    • /
    • 2008
  • The performance of hose reel hydrant system and indoor hydrant system was tested comparatively. At that result, a hose reel hydrant system are excellent and have the same performance as indoor hydrant system. If hose reel hydrant system has the performance that pressure is more than 0.17 MPa and flow-rate is over 130 LPM at the nozzle, it can be substituted for indoor hydrant system.

  • PDF

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF