• Title/Summary/Keyword: Horizontal transmission

Search Result 208, Processing Time 0.024 seconds

Responses of Inferior Olive Neurons to Stimulation of Semicircular Canals

  • Park, Sah-Hoon;Park, Jong-Seong;Lee, Min-Su;Shin, Jung-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.6 no.4
    • /
    • pp.193-197
    • /
    • 2002
  • In spite of abundant anatomical evidences for the fiber connection between vestibular nuclei and inferior olivary (IO) complex, the transmission of vestibular information through the vestibulo- olivo-cerebellar climbing fiber pathway has not been physiologically established. The aims of the present study were to investigate whether there are IO neurons specifically responding to horizontal rotation and also in which subregions of IO complex these vestibularly-activated neurons are located. The extracellular recording was made in 68 IO neurons and responses of 46 vestibularly-activated cells were analyzed. Most of the vestibularly-activated IO neurons responded to signals of vertical rotation (roll), while a small number (13/46) of recorded cells were activated by horizontal canal signal (yaw). Regardless of yaw-sensitive or roll-sensitive, vestibular IO neurons were excited, when the animal was rotated to the side contralateral to the recording side. The gain and excitation phase were very similar to otolithic or vertical-canal responses. Histologic identification of recording sites showed that most of vestibular IO neurons were located in ${\beta}$ subnucleus. Electrical stimulation of a HSC evoked an inhibitory effect on the excitability of the ipsilateral IO neurons. These results suggest that IO neurons mainly in the ${\beta}$ subnucleus receive vestibular signals from semicircular canals and otolithic organs, encode them, and transmit vestibular information to the cerebellum.

A Handover Technique in a Dual-mode Base Station (이중모드 기지국에서의 핸드오버 기법)

  • Jeong Tae-Eui;Shin Yeon-Seung;Ju Sang-Don;Song Byung-Kwon
    • The KIPS Transactions:PartC
    • /
    • v.13C no.2 s.105
    • /
    • pp.177-184
    • /
    • 2006
  • A handover is a technology that enables data transmission and receipt seamlessly while a mobile station moves from the current base station to another base station. The handover is basically classified into two types; a horizontal handover which changes a radio link only without changing a network link, and a vertical handover which changes both in heterogeneous networks. In this paper, we propose a vertical handover protocol in a dual base station which supports both of W-CDMA and WiBro networks based on SDR (Software Defined Radio), verify the rightness using a state transition diagram and a Petri-net, and evaluate the performance of the proposed protocol using NS-2 simulator.

Design and Fabrication of InP/InGaAs PIN Photodiode for Horizontally Integrated OEIC's (수평집적형 광전자집적회로를 위한 InP/InGaAs PIN 광다이오드의 설계 및 제작)

  • 여주천;김성준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.38-48
    • /
    • 1992
  • OEIC(Optoelectronic Integrated Circuit)'s can be integrated horizontally or vertically. Horizontal integration approach is, however, more immune to parasitic and more universally applicable. In this paper, a structural modeling, fabrication and characterization of PIN photodiodes which can be used in the horizontal integration are performed. For device modeling, we build a transmission line model from 2-D device simulation, from which lumped model parameters are extracted. The speed limits of the PIN photodiodes can also be calculated under various structural conditions from the model. Thus optimum design of horizontally integrated PIN photodiodes for high speed operation are possible. Such InGaAs/InP PIN photodiodes for long-wavelength communications are fabricated using pit etch, epi growth, planarization, diffusion and metallization processes. Planarization process using both RIE and wet etching and diffusion process using evaporated Zn$_{3}P_{2}$ film are developed. Characterization of the fabricated devices is performed through C-V and I-V measurements. At a reserve bias of 10V, the dark current is less than 5nA and capacitance is about 0.4pF. The calculated bandwidth using the measured series resistance and capacitance is about 4.23GHz.

  • PDF

Horizontal Protocol Processing Architecture for High Performance Parallel Processing (고성능 병렬 처리를 위한 수평적인 프로토콜 처리 구조)

  • Kim, Pyeong-Jung;Park, Chi-Hang
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.6
    • /
    • pp.1386-1396
    • /
    • 1996
  • In the distributed multimedia application, high throughput and low delay is one of the most important QoS(Quality of Service) requirement. Emerging high speed communication offers transmission rate above Gbps, but it can not be utilized efficiently by the performance bottlenecks of communication protocols. To overcom the problem, we propose a horizontal processing architecture that processes data as soon as it arrive from the network. Unfortunately, the OSI protocol stack often imposes ordering constraints that prevent concurrent processing of the protocol layers. By using a fixed packet format, the network layer through the presentation layer are processed in parallel. Our prototype shows that the proposed model has performance improvement up to 61% more advantage than the conventional approach.

  • PDF

Three-dimensional beamforming techniques for LTE-A systems (LTE-A 시스템에서 3 차원 빔포밍 기법 연구)

  • Ji, Hyoungju;Shim, Byonghyo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.11a
    • /
    • pp.43-44
    • /
    • 2015
  • LTE-Advanced system has been deployed with 2 and 4 transmission antennas (Tx) while the specification supports up to 8Tx. Due to deployment space, antenna dimension and complexity, the needs of deploying 8Tx system has not been motivated by operators. Recently, three dimensional (3D) beamforming with active antenna has attracted significant attention in the wireless industry. By incorporating 2D active array into LTE-A systems, the system offers freedom in controlling radiation on elevation and horizontal dimension. When the number of antennas increases in the form of 2D arrangement, spatial separation can be realized simultaneously in horizontal and elevation domain and vertical beam-steering can increase SINR of UEs in high floors. In this paper, we study the system operations and implementations for supporting 3D beamforming with 8Tx antennas. In our schemes, by reusing the conventional CSI feedback framework, the system can operate 2D active array without harming the backward compatibility. Evaluation results show that 3D beamforming provides capacity boosting over the conventional 2D beamforming systems while keeping same antenna structure.

  • PDF

A Study on the Behavioral Characteristics of a Circular Foundation Dominated by Pull-Out Load through Field Test (현장시험을 통한 인발하중이 지배적인 원형기초의 거동 특성 연구)

  • Shin, Kyung-Ha;Lee, Seung-Ho;Lee, Dong-hyuk;Park, Du-hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.53-62
    • /
    • 2021
  • For the rational application of LRFD, which is actively applied in Korea, for the study of the pull-out load and the horizontal load, which are insufficient examples, a circular foundation based on the transmission tower foundation, which is a socially important structure, through field tests in single and mixed layer. Factors that can affect the design were studied by analyzing the resistance of each stratum to pull-out and horizontal loads.

Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line (송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석)

  • Myung, Sung-Ho;Cho, Yeon-Gyu;Lee, Dong-Il;Lim, Yun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1132-1142
    • /
    • 2006
  • This paper examined electric power transmission line models of reducing ELF(Extremely Low Frequency) magnetic field and analyzed the effects about models. In this research, FRF(Field Reduction Factor) of various models reducing magnetic field were analyzed compared to the horizontal 154 kV transmission line. As a result, the reduction ratio of magnetic field was almost proportioned to the compaction of phase-to-phase distance, and in case of diamond model and transposed model, magnetic field was able to be reduced nearly 50 %. It was analyzed that the magnetic field reduction ratio of triangle model was about 33 % and the magnetic field reduction ratio of split model was able to be reduced to 50 %. Especially, the magnetic field reduction ratio of multi split model could be reduced to 80 %.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

Study on Ultimate Behavior of Steel Transmission Tower with Residual Stress and Initial Imperfection (잔류응력과 초기변형을 고려한 송전철탑의 비선형 극한거동에 관한 해석적 연구)

  • Chang, Jin Won;Kim, Seung Jun;Park, Jong Sup;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.421-435
    • /
    • 2008
  • This paper presents an investigation on the ultimate behavior of a transmission tower using nonlinear analyses inconsideration of residual stress and initial imperfection. Main members, such as main post, horizontal member and diagonal member of the transmission tower were modeled using beam element. Moreover, submembers of the transmission tower were modeled using truss element. ABAQUS (2004) program was used to perform finite element analyses. Initial condition options of the ABAQUS program considering initial stress and imperfection were used in this study. Before performing the analysis of the total transmission tower, simple angle section models using beam or plate/shell element w ere investigated to verify the appropriateness of ABAQUS analysis models and options. According to the verification results, the beam element was used for nonlinear analyses of the transmission tower. From nonlinear analyses results, buckling failure was in the main member of the leg part because of ${P-{\triangle}}$ effect at that point. Also, this paper includes significant results to define real structural failure modes and quantitative values. This study should be used in the development of a reasonable and economic design method for transmission towers.

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis (적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가)

  • Moon, Jong-Pil;Yun, Nam-Kyu;Lee, Sung-Hyoun;Kim, Hak-Joo;Lee, Su-Jang;Kim, Young-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.