• Title/Summary/Keyword: Horizontal effective range

Search Result 58, Processing Time 0.023 seconds

Effects of Soft Tissue Massage of the Posterior Deltoid Muscle on Shoulder Horizontal Adduction

  • Park, Kyue-Nam;Kwon, Oh-Yun;Kim, Si-Hyun;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.35-40
    • /
    • 2010
  • Stiffness of the posterior deltoid is as a causative factor in the limited range of glenohumeral horizontal adduction and various other shoulder pathologies including shoulder impingement syndrome, frozen shoulder, and humerus anterior glide syndrome. The purpose of this study was to compare the effects of two techniques (soft tissue massage and cross-body stretch) on increasing the range of horizontal adduction. Thirty-two subjects with a $10^{\circ}$ or greater difference between the right and left sides in horizontal adduction were selected. Sixteen subjects from each group were allocated randomly. Interventions were applied on six occasions for 2 weeks, and the range of horizontal adduction was measured using an inclinometer at pre-and post-intervention. A $2{\times}2$ analysis of variance (intervention${\times}$time) was used to compare the effects of the two techniques. In the soft tissue massage group, the angle of horizontal adduction significantly increased compared with the cross-body stretch group. These findings indicate that the soft tissue massage of the posterior deltoid muscle is a more effective method to increase the flexibility of the glenohumeral horizontal adduction.

Clogging behavior of recycled aggregates and crushed stone as horizontal drains in soft ground (연약지반에서 수평배수재용 순환골재와 쇄석의 막힘 거동)

  • Lee, Dal-Won;Noh, Jae-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.3
    • /
    • pp.253-260
    • /
    • 2013
  • In this study, laboratory model test carried out to present the suitable range of particle size distribution and clogging behavior of recycled aggregates and crushed stone as horizontal drains in soft ground. The recycled aggregates and crushed stone showed clogging phenomenon because the top fill material and bottom clay inflow into the horizontal drains. The pp mat was the most effective method to minimize clogging phenomenon. The horizontal coefficient of permeability in case of installing the pp mat showed largely 2.1 times more than the case of not installing. When the pp mat is not installing, the thickness of fine grained soil inflow into the horizontal drains showed 6.7~13.3% range in top fill material and 3.3~6.7% range in bottom clay. Overall, the reduction of the discharge capacity by fine grained soil inflow showed small in recycled aggregates and crushed stone. Also, the appropriate criterion range of particle size distribution is presented to make use of a horizontal drains in soft ground on the basis of laboratory test.

Thermal Convection with Conducting Lid (전도체가 존재하는 자연대류 현상에 대한 수치적 유동 가시화)

  • Ha Man Yeong;Lee Jae Ryong;Balachandar S.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.117-120
    • /
    • 2005
  • This study of thermal convection uses the following geometry: a horizontal layer of fluid heated from below of solid lid at bottom and cooled from above. A variety range of thermal conductivity ratio, $\kappa$ is considered to investigate the interface temperature, $\theta_{i}$ between solid and fluid region. Periodic boundary conditions are employed in the horizontal direction to allow for lateral freedom for the convection cells. A two-dimensional solution for unsteady natural convection is obtained, using an accurate and efficient Chebyshev spectral multi-domain methodology, for different effective Rayleigh numbers, $Ra_{eff}$ varying over the range of $10^{4}\;to\;10^{7}$ in which the effective Rayleigh number is defined as $Ra{\times}<\overline{T}_{i}>$.

  • PDF

Immediate Effects of Soft Tissue Massage on Posterior Shoulder Muscle Tightness: A Preliminary Study

  • Choi, Sil-Ah;Lee, Ji-Hyun;Yoon, Tae-Lim;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.8-15
    • /
    • 2012
  • Posterior shoulder muscle tightness is frequently observed in shoulder impingement syndrome because tightness in the posterior portion of the shoulder muscles can cause anterior and superior translation of the humeral head in relation to the glenoid fossa. The purpose of this study was to determine the immediate effects of soft tissue massage on acromiohumeral distance (AHD), anterior translation of the humeral head, and glenohumeral (GH) range of motion (ROM) in subjects with posterior shoulder muscle tightness. Twenty-seven subjects with greater than $10^{\circ}$ difference in the range of GH horizontal adduction between right and left sides were recruited. The range of GH horizontal adduction and internal rotation were measured by a digital inclinometer. The AHD and anterior translation of the humeral head were measured using ultrasonography. A paired t-test was used to compare AHD, anterior translation of the humeral head, and the range of GH horizontal adduction and internal rotation before and after soft tissue massage. The results showed that AHD increased significantly (p<.05) and the anterior translation of humeral head decreased slightly, but not significantly (p=.40) after the soft tissue massage. Furthermore, the ROM of horizontal adduction and internal rotation in the GH joint increased significantly after the soft tissue massage (p<.05). These findings indicate that soft tissue massage on posterior shoulder muscle tightness is an effective method to increase AHD and ROM in the horizontal adduction and internal rotation of the GH joint.

Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser (냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성)

  • Han Hwataik;Shin Min-Woo;Yom Chol-Min;Choi Sun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

Depth estimation of an underwater target using DIFAR sonobuoy (다이파 소노부이를 활용한 수중표적 심도 추정)

  • Lee, Young gu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.302-307
    • /
    • 2019
  • In modern Anti-Submarine Warfare, there are various ways to locate a submarine in a two-dimensional space. For more effective tracking and attack against a submarine the depth of the target is a critical factor. However, it has been difficult to find out the depth of a submarine until now. In this paper a possible solution to the depth estimation of submarines is proposed utilizing DIFAR (Directional Frequency Analysis and Recording) sonobuoy information such as contact bearings at or prior to CPA (Closest Point of Approach) and the target's Doppler signals. The relative depth of the target is determined by applying the Pythagorean theorem to the slant range and horizontal range between the target and the hydrophone of a DIFAR sonobuoy. The slant range is calculated using the Doppler shift and the target's velocity. the horizontal range can be obtained by applying a simple trigonometric function for two consecutive contact bearings and the travel distance of the target. The simulation results show that the algorithm is subject to an elevation angle, which is determined by the relative depth and horizontal distance between the sonobuoy and target, and that a precise measurement of the Doppler shift is crucial.

A Study on the Characteristics of Mammoth Vibro Tamper by Numerical Analysis (대형진동햄머다짐의 수치해석적 연구)

  • 박양수;박인준;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.45-54
    • /
    • 2000
  • 경험적으로 방법에 의존해온 대형 진동햄머다짐의 영향심도를 평가하고자 수치해석적인 기법을 사용하였다. 수치해석적인 기법을 사용하였다. 수치해석에 사용한 프로그램은 범용 유한요소 해석프로그램인 ABAQUS이며, 인천 신공항 매립지에서 시험 시공한 대형 진동햄머다짐의 자료와 수치해석한 결과의 비교를 통해 검증하였다. 수치해성에 사용한 물성은 현장시험과 실내시험을통해 구하였으며 영향깊이는 지반이 동적 하중에 변형할 때 소산하는 소성변형율에너지량의 분포를 판정하였다. 수치해석결과 소성변형율에너지 소산량의 시간에 따른 변화로부터 다짐의 영향깊이 및 수평영향거리를 추정할 수 있었다. 소성변형율에너지 수렴시의 외부에너지를 Menard의 경험식에 적용할 경우 영향깊이를 판정할 수 있음을 알았다. 따라서 Menardtlr으로부터 영향깊이를 다짐하는데 필요한 최소한의 에너지를 구할수 있을 것으로 판단된다.

  • PDF

A Study on the Torsional Vibration Measurement of the Horizontal Shaft with Disks (단을 가진 수평축의 비틀림진동 측정에 관한 연구)

  • 박일수;안찬우;김중완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.3-8
    • /
    • 1997
  • This parer was presented for the experimental results of torsional vibrations of the horizontal rotating shaft with three disks. The torsional vibrations meter used is a laser system for non-contact measurement of torsional angular vibration velocity and torsional angular vibration displacement. The distance between the disks war changed; the one that had 76mm of disk distance war called basic model, and another that had 106mm of disk distance wide model, and other that had 46mm of disk distance narrow model. In each model, outer diameter of disk was 40mm. And 45mm, or 50mm was also used to extend the effective range of frequencies. The angula vibration displacement and the angular vibration velocity in its torsional vibration were measured to obtain the stable and the unstable regions.

  • PDF

Investigation of the Effective Range of Cathodic Protection for Concrete Pile Specimens Utilizing Zinc Mesh Anode

  • Duhyeong Lee;Jin-A Jeong
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.195-202
    • /
    • 2024
  • A zinc mesh sacrificial anode cathodic protection method is recently being developed to protect the reinforced concrete structure in a marine environment. However, comprehensive information regarding the cathodic protection technology applied to reinforced concrete test specimens utilizing zinc mesh sacrificial anodes remains limited. Particularly, no research has investigated the effective range of sacrificial anode cathodic protection in a reinforced concrete structure regarding the transmission of protection current from zinc mesh sacrificial anode to the reinforced concrete structure, particularly concerning effects of temperature variations. This study examined the distribution of potential and current using a long single rebar and several segment reinforcing bars inside a horizontal beam. Vertical pile specimens were applied with a zinc mesh sacrificial anode to simulate concrete bridges or harbor structures. To check the effect of cathodic protection, cathodic protection potential and current of the reinforced concrete specimens were measured and 100 mV depolarization criterion test was performed. It was confirmed that effect of cathodic protection varied depending on resistivity and temperature. The cathodic protection test of pile specimens revealed that the maximum reachable range of cathodic protection current was 10 cm from the waterline as observed in the experiment.

Evaluating the effective spectral seismic amplification factor on a probabilistic basis

  • Makarios, Triantafyllos K.
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.121-129
    • /
    • 2012
  • All contemporary seismic Codes have adopted smooth design acceleration response spectra, which have derived by statistical analysis of many elastic response spectra of natural accelerograms. The above smooth design spectra are characterized by two main branches, an horizontal branch that is 2.5 times higher than the peak ground acceleration, and a declining parabolic branch. According to Eurocode EN/1998, the period range of the horizontal, flat branch is extended from 0.1 s, for rock soils, up to 0.8 s for softer ones. However, from many natural recorded accelerograms of important earthquakes, the real spectral amplification factor appears to be much higher than 2.5 and this means that the spectrum leads to an unsafe seismic design of the structures. This point is an issue open to question and it is the object of the present study. In the present paper, the spectral amplification factor of the smooth design acceleration spectra is re-calculated on the grounds of a known "reliability index" for a desired probability of exceedance. As a pilot scheme, the seismic area of Greece is chosen, as it is the most seismically hazardous area in Europe. The accelerograms of the 82 most important earthquakes, which have occurred in Greece during the last 38 years, are used. The soil categories are taken into account according to EN/1998. The results that have been concluded from these data are compared with the results obtained from other strong earthquakes reported in the World literature.