• 제목/요약/키워드: Homogeneity-range

검색결과 172건 처리시간 0.025초

기상관측소의 이전이 계절평균 일교차의 균질성에 미치는 영향 (The Relocation Effect of Observation Station on the Homogeneity of Seasonal Mean of Diurnal Temperature Range)

  • 김지현;서명석;홍순희
    • 대기
    • /
    • 제20권4호
    • /
    • pp.437-449
    • /
    • 2010
  • The relocation effect of observation station (REOS) on the homogeneity of seasonal mean of maximum and minimum temperature, diurnal temperature range (DTR) and relative humidity (RH) was investigated using surface observation data and document file. Twelve stations were selected among the 60 stations which have been operated more than 30 years and relocated over one time. The data from Chunpungryeong station were used as a reference to separate the impacts of station relocation from the effects caused by increased green house gases, urbanization, and others. The REOS was calculated as a difference between REOS of relocated station and REOS of reference station. Although the REOS is clearly dependent on season, meteorological elements, and observing stations, statistically significant impacts are found in many stations, especially the environment of observing station after relocation is greatly changed. As a result, homogeneity of seasonal mean of meteorological elements, especially DTR and RH, is greatly reduced. The results showed that the effect of REOS, along with the effect of urbanization, should be eliminated for the proper estimation of climate change from the analysis of long-term observation data.

A GENERALIZATION OF THE INTRACLASS CORRELATION IN CLUSTER SAMPLING

  • KIM KYU-SEONG
    • Journal of the Korean Statistical Society
    • /
    • 제34권3호
    • /
    • pp.185-195
    • /
    • 2005
  • This article is concerned with the intraclass correlation in survey sampling. From a design-based viewpoint the intraclass correlation is generalized to a finite population with unequal sized clusters. Under simple random cluster sampling the intraclass correlation is given in an explicit form, which is a generalization of the usual one. The range of it is found and the design effect is expressed by means of it. An example is given to compare the intraclass correlation with the homogeneity measure numerically, which shows that two measures are not the same except some limited cases.

심장 횡단면의 전위분포 컴퓨터 시뮬레이션 (Computer Simulation of the Electric Potential Distribution of Human Cross Section)

  • 고용훈;박상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.65-70
    • /
    • 1982
  • This paper presents a new method of solving the electric potential distribution using the finite element method. The thoracic region surrounded by the body surface and the heart is discretized into finite elements and the Continuous Laplace-equation is transformed into one of the finite degrees of freedom. The current source density, the conductivity, and the excitable range is obtained by the references. From the result of simulation, it was revealed that the potential pattern of in homogeneity was much different from that of homogeneity.

  • PDF

계조 화소 값을 이용한 노출속도가 다른 두 영상의 피라미드 융합 방법 (A Pyramid Fusion Method of Two Differently Exposed Images Using Gray Pixel Values)

  • 임수진;김진헌
    • 한국멀티미디어학회논문지
    • /
    • 제19권8호
    • /
    • pp.1386-1394
    • /
    • 2016
  • Pyramid fusion usually adjusts the Laplacian weights of pixels of the input images by evaluating predefined criteria. This has advantages that it can selectively express intense color and enhance the contrast when applied to HDR exposure fusion. But it may cause noise because the weights are determined by pixel importance without considering the interdependent pixel relationship that constitutes a scene. This paper proposes a fusion method using simple weight criteria generated from the gray pixel values, which is expected to preserve the interdependent relationship and improve execution speed. In order to evaluate the performance of the proposed method we examine a homogeneity measure, H and compare the execution time for both methods. The proposed method is found to be more advantageous with respect to homogeneity and execution speed.

소의 자궁 및 고환에서 Phospholipase C의 분리 및 뇌 Isozyme과의 비교 연구 (Homogeneity of Phospholipase C of Bovine Uterus and Seminal Vesicle Compared with Brain Isozymes)

  • 김정희;;이기녕
    • Journal of Yeungnam Medical Science
    • /
    • 제5권2호
    • /
    • pp.37-45
    • /
    • 1988
  • Phospholipase C는 second messenger로서 세포 밖의 signal transduction에 중요한 효소 이다. 본 연구에서 소의 뇌, 자궁 및 고환에서 high performance liquid chromatography(HPLC)를 이용하여 phospholipase C(PLC)를 추출하였으며 뇌에서 3개의 isozyme(F-1, F-2, F-3), 자궁과 고환에서 각각 2개의 isozyme을 얻었고 HPLC에서의 retension time을 구하였다. Homogeneity 검사를 위하여 소 brain의 각 isozyme I, II 및 III에 대한 PLC-monoclonal antibody(Mab)를 affigel에 label 시켰고 결합능(binding capacity)는 73.8~97.5%였다. PLC-Mab와 자궁 및 고환의 PLC isozyme과의 homogeneity 검사에서 binding capacity는 자궁의 F-1은 PLC III가 주이며 F-2는 DEAE column에서는 II가 주이나 phenyl column에선 I과 II가 주이고 고환에선 F-1은 PLC III가 주이고 F-2에서는 PLC II가 주인 것으로 나타났다.

  • PDF

Gabor 필터의 위상 정보를 이용한 거리 영상의 분할 및 분류 (Segmentation and Classification of Range Data Using Phase Information of Gabor Fiter)

  • 현기호;이광호;황병곤;조석제;하영호
    • 대한전자공학회논문지
    • /
    • 제27권8호
    • /
    • pp.1275-1283
    • /
    • 1990
  • Perception of surfaces from range images plays a key role in 3-D object recognition. Recognition of 3-D objects from range images is performed by matching the perceived surface descriptions with stored object models. The first step of the 3-d object recognition from range images is image segmentation. In this paper, an approach for segmenting 3-D range images into symbolic surface descriptions using spatial Gabor filter is proposed. Since the phase of data has a lot of important information, the phase information with magnitude information can effectively segment the range imagery into regions satisfying a common homogeneity criterion. The phase and magnitude of Gabor filter can represent a unique featur vector at a point of range data. As a result, range images are trnasformed into feature vectors in 3-parameter representation. The methods not only to extract meaningful features but also to classify a patch information from range images is presented.

  • PDF

뇌종양 환자의 양성자 치료 시 Range Compensator의 Smooth Thickness 적용에 따른 선량비교 (Dose comparison according to Smooth Thickness application of Range compensator during proton therapy for brain tumor patient)

  • 김태완;김대웅;김재원;정경식
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.139-148
    • /
    • 2016
  • 목 적 : 양성자 치료 시 사용되는 Range Compensator는 Target의 Distal Margin의 선량에 대해 정상조직에 전달되는 양성자 빔 선량을 보정하는 역할을 한다. 이에 뇌종양 치료에 사용되는 Range Compensator의 Smooth Thickness를 다르게 적용함에 따른 PTV와 OAR의 선량을 비교하여 대상 부위의 선량이 개선되는 것을 확인해 보고자 한다. 대상 및 방법 : 본원에서 양성자 치료를 받은 뇌종양 환자 10명을 대상으로 Eclipse Proton Planning System(Version 10.0, Varian, USA)의 Compensator Editor를 사용하여 Range Compensator에 적용되는 Smooth Thickness를 각각 1회에서 5회까지 순차적으로 적용하였다. 치료계획의 알고리즘은 Proton Convolution Superposition(version 8.1.20 or 10.0.28)을 사용하였고, Smooth Thickness를 단계적으로 적용함에 따른 PTV의 Dmax, Dmin, Homogeneity Index, Conformity Index 그리고 종양주위의 OAR 선량을 비교하였다. 결 과 : Smooth Thickness를 1회에서 5회까지 적용하였을 때 PTV의 최대선량(Dmax)은 최대 4.3%, 최소 0.8%, 평균 1.81% 감소하였으며, 최소선량(Dmin)은 최대 1.8%, 최소 0.2%, 평균 0.82% 증가하였고, 최대선량과 최소선량의 차이는 최대 5.9%, 최소 1.4%, 평균 2.63% 감소하였다. Homogeneity Index는 평균 0.018 감소하였고 Conformity Index는 거의 변화가 없었다. OAR 선량은 Brain Stem에서 최대 1.6%, 최소 0.1%, 평균 0.59% 감소하였으며, Optic Chiasm에서 최대 1.3%, 최소 0.3%, 평균 0.45% 감소하였으나, C와 E환자가 각각 0.3%, 0.6% 증가하였다. 그리고 Rt. Optic Nerve에서 최대 1.5%, 최소 0.3%, 평균 0.8% 감소하였으나, B환자가 0.1% 증가하였다. Lt. Optic Nerve에서는 최대 1.8%, 최소 0.3%, 평균 0.67% 감소하였으나, H환자가 0.4% 증가하였다. 결 론 : 뇌종양 환자의 양성자 치료에 사용되는 Range Compensator의 Smooth Thickness가 단계적으로 적용될수록 Compensator의 해상도가 증가하여 가장 최적화된 양성자 빔 선량을 전달할 수 있다. 이는 PTV에 좀 더 균일한 선량을 조사할 수 있고 또한 OAR에 작용하는 불필요한 선량을 감소시켜 부작용을 줄일 수 있을 것으로 사료된다.

  • PDF

설계파고 추정에 사용한 연 최대 자료의 독립 및 분포 동질 검정 (Independence and Homogeneity Tests of the Annual Maxima Data used to Estimate the Design Wave Height)

  • 조홍연;정원무;백종대
    • 한국해안·해양공학회논문집
    • /
    • 제32권1호
    • /
    • pp.26-38
    • /
    • 2020
  • 설계파고 추정에 사용한 AM 자료의 IID 가정에 대한 검정을 수행하였다. 검정은 독립 검정, 분포 차이 검정으로 구분하고, 각각의 검정은 태풍, 비태풍 조건에서의 연안 격자, 연안 내부격자 각각 210개, 310개 지점의 AM 자료 세트를 대상으로 수행하였다. 독립 검정 결과, 비태풍, 태풍 자료 세트에 대하여 각각 1.8~5.3%, 1.4~6.0% 범위의 기각 비율을 보여, 대부분의 자료가 독립 검정을 만족하는 것으로 파악되었다. 한편 태풍 자료와 비태풍 자료의 분포 차이 검정은 연안 격자와 연안 내부격자 모두 검정 방법에 따라 47~79% 범위로 동일분포 가설이 기각되는 것으로 파악되었다. 따라서 극치해석에 의한 설계파고 추정에서 두 자료를 구분하여 각각 설계파고를 추정하는 과정이 적절하다.

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • 제34권4호
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

Image에 따른 효과적인 LCD 백라이트 Block 단위 Nonideality 및 Cross-talk Compensation (Efficient Image Specific Block Based LCD Backlight Nonideality and Cross-talk Compensation)

  • 한원진;유재희
    • 대한전자공학회논문지SP
    • /
    • 제48권4호
    • /
    • pp.38-48
    • /
    • 2011
  • Backlight Profile과 Image Pixel의 Homogeneity 분석을 통한 Block 단위 LCD Backlight Nonideality 및 Crosstalk Compensation 방안이 제안되었다. Image에 따라 Block Size 및 연산에서 제외되는 Block 범위 그리고 연산에 고려되는 Backlight 범위를 최적화하여, 화질을 유지하면서 연산량을 최소화시켰다. 실제 영상을 바탕으로 하는 Simulation을 통해 제안된 Compensation 연산량과 화질이 평가되었다.