• 제목/요약/키워드: Hollow

검색결과 2,247건 처리시간 0.019초

Exact solution for asymmetric transient thermal and mechanical stresses in FGM hollow cylinders with heat source

  • Jabbari, M.;Vaghari, A.R.;Bahtui, A.;Eslami, M.R.
    • Structural Engineering and Mechanics
    • /
    • 제29권5호
    • /
    • pp.551-565
    • /
    • 2008
  • Transient solution of asymmetric mechanical and thermal stresses for hollow cylinders made of functionally graded material is presented. Temperature distribution, as function of radial and circumferential directions and time, is analytically obtained, using the method of separation of variables and generalized Bessel function. A direct method is used to solve the Navier equations, using the Euler equation and complex Fourier series.

Thixoforging에 의한 중공형 금속복합재료 부품의 기계적 특성 (Mechanical Properties for Hollow Shape Part of Metal Matrix Composites by Thixoforging)

  • 허재찬;이승후;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2001
  • MMC was developed that had distinguished mechanical properties and light weighted. MMC has excellent mechanical properties in many ways in automotive industrial, and get into the spotlight as a light materials substituted for iron and steel. But the know-how about MMC research lack, MMC is expensive and difficult to apply the sound parts. Especially it is difficult to produce the hollow type parts composed with MMC. Therefore, hollow type parts of metal matrix composites by thixoforging process which as co-existing solidus-liquidus phase, it is very important to obtain forming condition. In this study, used materials were A357, A380, A380 $10\%$vol, and $20\%$vol SiCp, and the size of particulates were $14{\mu}m$ and $5.5{\mu}m$

  • PDF

개방형 Hollow 폐색장치의 임상 증례 (A CASE REPORT OF OPEN TYPE HOLLOW OBTURATOR)

  • 정문규;배정식
    • 대한치과보철학회지
    • /
    • 제26권1호
    • /
    • pp.207-212
    • /
    • 1988
  • Maxillary defects are a result of necessary cancer surgery, congenital anomaly or trauma. Ideally the patient with the aquired maxillary defect should be provided with an obturator prosthesis that is comfortable, restores adequate speech, deglutition, and mastication, and is acceptable cosmetically. This is a case report of open type hollow obturator delivered in the partial maxillectomy treated patient. The satisfied result obtained as follows: The open type hollow obturator has the advantage of easy fabrication, lightness, easy cleaning and restores adquate speech.

  • PDF

Hollow Fiber 막에 의한 Pichia stipitis의 Cross Flow여과 (Cross Flow Filtration of Pichia stipitis by a Hollow Fiber Membrane)

  • 김홍;정인식
    • KSBB Journal
    • /
    • 제4권1호
    • /
    • pp.57-61
    • /
    • 1989
  • 발효액에서 hollow fiber membrane에 의한 Pichia sti-pitis의 분리 공정의 가능성을 검토해 보았다. Permeateflux는 cell의 농도, pH, antifoam agent의 농도, 여과 압력, 그리고 recircultion rate에 의해 영향을 받았으며 온도는 flux의 감소와 별로 관계가 없는 것으로 나타났다. 아울러 microcomputer에 조절되어 membrane을 backflush하는 것이 memnrane의 fouling 문제를 경감 시켜서 발효액에서 P. stipitis를 분리하는 공저의 연장된 조업을 가능케 함을 확인 하였다.

  • PDF

담체 모양변화에 따른 유기물 처리 성능 고찰 (Performance of Organic Treatment with Shape Modify of Ceramic Support Carrier)

  • 박영식;안갑환
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.27-34
    • /
    • 2001
  • This paper discussed the shape effect of ceramic support carrier in order to facilitate biomass immobilization. The shape of ceramic support carrier was modified hollow pipe type into hollow gear type. After seeding, microorganisms were attached in crevices where protection from shear forces or surfaces where easy to contact with support carrier surface. In case of hollow gear type carrier, initial attachment rate was faster than that of hollow pipe type and obtained thick biofilm. Synthetic wastewater(COD:75~880 mg/L, organic loading rate:0.36~4.22 kgCOD/㎥.d) was treated aerobic fixed bed biofilm reactor where 100% of the volume was filled with the ceramic carrier. COD removal efficiency of reactor filled with gear type support carrier was a little high withing 70 days, and then showed similar removal efficiency. It was found that highly loaded operation with up to 4.22 kgCOD/㎥.d was possible in both reactor. Total biomass amounts of pipe type was higher than gear type, however, attached biomass of gear type was higher than that of pipe type.

  • PDF

실관막모듈에 의한 중금속염 혼합용액으로부터 Cr(VI) 분리 (Separation of Cr(VI) from Heavy Metal Salts Mixed Solution by using Hollow Fiber Module)

  • 최대웅
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.107-112
    • /
    • 2001
  • This work reports the application of a hollow fiber module(HFM) for Cr(VI) extraction from heavy metal salts mixed solution by using microporous hydrophobic hollow fiber module. In HFM configuration, the organic extraction used for the extraction of Cr(VI) was di-(2-ethyl hexyl) phosphoric acid(D2EHPA) diluted with n-heptane. The study of HFM includes the influence of hydrodynamic and chemical condition, i.e., the flow rate of feed solution, the time of reactive extraction, the concentration of feed solution, and the pH of aqueous phase solutions. Several experiments with synthetic solution of different mixed components system of Cr(VI) solutions established optimum condition to achieve a clean separation of Cr(VI). It was possible to separate Cr(VI) in the presence of metal salts mixed solution, such as Zn(II), Ni(II), Cu(II), and Cd(II) using the HFM technique.

  • PDF

Asymmetric transient thermal stress of a functionally graded hollow cylinder with piecewise power law

  • Ootao, Yoshihiro;Ishihara, Masayuki
    • Structural Engineering and Mechanics
    • /
    • 제47권3호
    • /
    • pp.421-442
    • /
    • 2013
  • This paper is concerned with the theoretical treatment of transient thermoelastic problems involving a functionally graded hollow cylinder with piecewise power law due to asymmetrical heating from its surfaces. The thermal and thermoelastic constants of each layer are expressed as power functions of the radial coordinate, and their values continue on the interfaces. The exact solution for the two-dimensional temperature change in a transient state, and thermoelastic response of a hollow cylinder under the state of plane strain is obtained herein. Some numerical results for the temperature change and the stress distributions are shown in figures. Furthermore, the influence of the functional grading on the thermal stresses is investigated.

Eigenfunction expansion solution and finite element solution for orthotropic hollow cylinder under sinusoidal impact load

  • Wang, X.;Dai, H.L.
    • Structural Engineering and Mechanics
    • /
    • 제16권1호
    • /
    • pp.35-46
    • /
    • 2003
  • The histories and distributions of dynamic stresses in an orthotropic hollow cylinder under sinusoidal impact load are obtained by making use of eigenfunction expansion method in this paper. Dynamic equations for axially symmetric orthotropic problem are founded and results are carried out for a practical example in which an orthotropic hollow cylinder is in initially at rest and subjected to a dynamic interior pressure $p(t)=-{\sigma}_0(sin{\alpha}t+1)$. The features of the solution appear the propagation of the cylindrical waves. The other hand, a dynamic finite element solution for the same problem is also got by making use of structural software (ABAQUS) program. Comparing theoretical solution with finite element solution, it can be found that two kinds of results obtained by two different solving methods are suitably approached. Thus, it is further concluded that the method and computing process of the theoretical solution are effective and accurate.

Exact solution for forced torsional vibration of finite piezoelectric hollow cylinder

  • Wang, H.M.;Liu, C.B.;Ding, H.J.
    • Structural Engineering and Mechanics
    • /
    • 제31권6호
    • /
    • pp.663-678
    • /
    • 2009
  • An exact solution is obtained for forced torsional vibration of a finite class 622 piezoelectric hollow cylinder with free-free ends subjected to dynamic shearing stress and time dependent electric potential at both internal and external surfaces. The solution is first expanded in axial direction with trigonometric series and the governing equations for the new variables about radial coordinate r and time t are derived with the aid of Fourier series expansion technique. By means of the superposition method and the separation of variables technique, the solution for torsional vibration is finally obtained. Natural frequencies and the transient torsional responses for finite class 622 piezoelectric hollow cylinder with free-free ends are computed and illustrated.

Numerical investigation of continuous hollow steel beam strengthened using CFRP

  • Keykha, Amir Hamzeh
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.439-444
    • /
    • 2018
  • This paper presents a numerical study on the behavior of continuous hollow steel beam strengthened using carbon fiber reinforced polymers (CFRP). Most previous studies on the CFRP strengthening of steel beams have been carried out on the steel beams with simple boundary conditions. No independent study, to the researcher's knowledge, has studied on the CFRP strengthening of square hollow section (SHS) continuous steel beam. However, this study explored the effect of the use of adhesively bonded CFRP flexible sheets on the behavior of the continuous SHS steel beams. Finite Element Method (FEM) has been employed for modeling. Eleven specimens, ten of which were strengthened using CFRP sheets, were analyzed under different coverage length, the number of layers, and the location of CFRP composite. ANSYS software was used to analyze the SHS steel beams. The results showed that the coverage length, the number of layers, and the location of CFRP composite are effective in increasing the ultimate load capacity of the continuous SHS steel beams. Application of CFRP composite also caused the ductility increase some strengthened specimens.