Effect of Loading Path on the Hydroformability of a Three-layered Tube for Fabrication of a Hollow Part (중공품 성형시 삼중관의 액압성형성에 미치는 압력경로의 영향)

  • Han, S.W.;Kim, S.Y.;Joo, B.D.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.22 no.1
    • /
    • pp.17-22
    • /
    • 2013
  • Tube hydroforming is a technology that utilizes hydraulic pressure to form a tube into desired shapes inside die cavities. Due to its advantages, such as weight reduction, increased strength, improved quality, and reduced tooling cost, single-layered tube hydroforming is widely used in industry. However in some special applications, it is necessary to produce multi-layered tubular components which have corrosion resistance, thermal resistance, conductivity, and abrasion resistance. In this study, a hollow forming process to fabricate a part from multi-layered tubes for structural purposes is proposed. To accomplish a successful hydroforming process, an analytical model that predicts optimal load path for various parameters such as tube material properties, thickness of tubes, diameter of holes and the number of holes was developed. Tubular hydroforming experiments to fabricate a hollow part were performed and the optimal loading path developed by the analytical model was successfully verified. The results show that the proposed hydroforming process can effectively produce hollow parts with multi-layered tube without defects such as wrinkling or fracture.

A Study on Flexural Behavior of Precast Prestressed Concrete Hollow Slab Bridge (조립식 PSC 중공슬래브교의 휨거동에 관한 연구)

  • Kim, Ki-Yong;Song, Ha-Won;Kim, Ho-Jin;Byun, Keun-Joo;Kim, Yon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.524-527
    • /
    • 2004
  • Recently, precast concrete products have been increasingly used in the construction of bridges except for special bridges like long-span bridge due to their easy and high-quality construction. Specially the use of precast prestressed concrete hollow box slab bridges is also increased due to the merits in their construction. Thus, an experimental evaluation of flexural behavior of the precast PSC hollow box slab bridges and a development of effective analytical technique for the behavior are necessary. For the development, experimental study on the flexural behavior of the precast bridges up to ultimate states is needed. In this study, two full-scale precast PSC hollow box slab girders are manufactured and full-scale flexural failure tests of the girders subjected to cyclic loading are carried out. For the failure analysis of the girders, the so-called volume control method is applied to finite element analysis of the precast PSC hollow box slab girders discretized using multi-layered shell elements. The analytical results by the volume control method is verified by comparing with test results.

  • PDF

Formation of CdSe Hollow Sphere by In-Situ-Template-Interface Reaction (ISTIR) Method (In-Situ-Template-Interface Reaction (ISTIR)법에 의한 CdSe 중공 입자의 형성)

  • Choi Moon-Hee;Lee Yoon-Bok;Kim Hyong-Kuk;Rhyim Young-Mok;Kim Jin-Chun;Kim Young-Seok;Kim Yang-Do
    • Journal of Powder Materials
    • /
    • v.12 no.4 s.51
    • /
    • pp.291-295
    • /
    • 2005
  • CdSe hollow sphere with average size of about 30-50 nm was synthesized from the mixed solution of cadmium chloride $(CdCl_2)$, sodium selenosulfate $(Na_2SeSO_3)$ and ethylenediamine(EDA, $H_2NCH_2CH_2NH_2$) at room temperature. The molar ratio of EDA to $Cd^{2+}$ showed the most significant effect on the morphology of CdSe hollow sphere. This paper will present and discuss the possible formation mechanism of CdSe hollow sphere based on the observation of morphological changes.

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Seismic Performance Assessment of Hollow Circular Reinforced Concrete Bridge Columns with Confinement Steel (중공원형 철근콘크리트 교각의 횡방향철근에 따른 내진성능평가)

  • Kim, Tae-Hoon;Kang, Hyeong-Taek
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.13-25
    • /
    • 2012
  • The purpose of this study was to investigate the seismic behavior of hollow circular reinforced concrete bridge columns with confinement steel, and to develop improved seismic design criteria. Three hollow circular columns were tested under a constant axial load and a quasi-static, cyclically reversed horizontal load. The accuracy and objectivity of the assessment process can be enhanced by using a sophisticated nonlinear finite element analysis program. The numerical method used gives a realistic prediction of the seismic performance throughout the loading cycles for the several test specimens investigated. Based on the experimental and analytical results, design recommendations are presented to improve current practice in the design and construction of hollow circular reinforced concrete bridge columns.

Highly Sensitive and Selective Ethanol Sensors Using Magnesium doped Indium Oxide Hollow Spheres

  • Jo, Young-Moo;Lee, Chul-Soon;Wang, Rui;Park, Joon-Shik;Lee, Jong-Heun
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.4
    • /
    • pp.303-307
    • /
    • 2017
  • Pure $In_2O_3$, 0.5 and 1.0 wt% Mg doped $In_2O_3$ hollow spheres were synthesized by ultrasonic spray pyrolysis of a solution containing In-, Mg-nitrate and sucrose and their gas sensing characteristics to 5 ppm $C_2H_5OH$, p-xylene, toluene, and HCHO were measured at 250, 300 and $350^{\circ}C$. Although the addition of Mg decreases the specific surface area and the volume of meso-pores, the gas response (resistance ratio) of the 0.5 wt% Mg doped $In_2O_3$ hollow spheres to 5 ppm $C_2H_5OH$ at $350^{\circ}C$ (69.4) was significantly higher than that of the pure $In_2O_3$ hollow spheres (24.4). In addition, the Mg doped $In_2O_3$ hollow spheres showed the highest selectivity to $C_2H_5OH$. This was attributed to the dehydrogenation of $C_2H_5OH$ assisted by basic MgO into reactive $CH_3CHO$ and $H_2$.

Development of Material Nonlinear Models for Concrete in Internally Confined Hollow Members Considering Confining Effect (내부 구속 중공 CFT 부재 콘크리트의 비선형 재료 모델 개발)

  • Han Taek-Hee;Han Sang-Yun;Lim Nam-Hyoung;Kang Jin-Ook;Lee Myeoung-Sub;Kang Young-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.133-140
    • /
    • 2006
  • When concrete is confined triaxially, its strength and toughness are enhanced. Hoop reinforcements or transverse reinforcements laterally confine concrete in the case of a RC member and an outer tube confines concrete in a CFT(Concrete Filled Tube) member. But biaxially confined concrete. such as concrete in a hollow R.C member, does not have much enhanced strength and toughness. In this study, a new-type member. which is a hollow CFT member named as an ICH(Internally Confined Hollow) CFT member, was developed to overcome the low ductility of the hollow member and the high cost of the CFT member. A material nonlinear model for the concrete in an CFT member or an ICH CFT member was developed and coded as a computer program based on Mander's concrete model. Analysis results were verified with experimental results and the developed analysis model showed reasonable and accurate results.

  • PDF

Parametric Study on the P-M Interaction Diagram of Hollow Prestressed Concrete Bridge Columns (중공 프리스트레스트 콘크리트 교각의 P-M 상관도 매개변수 분석)

  • Kim, Tae-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.1-10
    • /
    • 2011
  • This study presents the results of parametric studies of the P-M interaction diagram of hollow prestressed concrete bridge columns. Among the numerous parameters, this study concentrates on concrete compressive strength, prestressing steel reinforcement ratio, effective prestress, the Ds/Do ratio, and the Di/Do ratio. The strength and ductility of hollow prestressed concrete bridge columns were evaluated through quasistatic tests. The P-M interaction diagrams from the codes were different from that of the results, which were in good agreement with AASHTO-LRFD. Nondimensionalized P-M interaction diagrams were developed to predict the design resistance of hollow prestressed concrete bridge columns.

Behavior of Internally Confined Hollow RC Columns (내부 구속 중공 RC 기둥의 거동 특성)

  • Han, Taek-Hee;Won, Deok-Hee;Yi, Gyu-Sei;Kang, Young-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.649-660
    • /
    • 2009
  • A nonlinear column model of an internally confined hollow (ICH) reinforced concrete (RC) column was suggested and a parametric study was performed. The suggested column model considered the confining effect and the material nonlinearity of concrete. To verify the suggested column model, its analysis results were compared with the test results from previous researchers and a quasi static test performed in this study. They showed that the suggested column model was reasonable and had acceptable accuracy. The results from parametric studies showed that the thickness of the internal tube, concrete strength, and the hollow ratio of the ICH RC column affected its behavior.

A Study on the Standardization of Fineness Measurement for the Thermal Insulator of Military Textiles (방한용 화섬솜의 섬도 측정방법의 표준화에 관한 연구)

  • Hong, Seong-don;Kim, Byung-soon
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.253-272
    • /
    • 2015
  • Purpose: The purpose of this study is to enhance the reliability of quality inspection by standardize the fineness test method of the thermal insulator of military textiles Methods: We have measured the thermal insulator of military textiles by microscope with three different ways and the effectiveness of their difference were analyzed by one-way layout design. Results: We have suggest the standardized the fineness test method of the thermal insulator of military textiles through advanced research. As a result we have verified hollow ratio of heat insulating fiber affect fineness test methods. The fineness test method for the thermal insulator applied with different methods following hollow ratio. We have verified that when the hollow ratio over 90%, the fineness of the thermal insulator measured from fiber-length, if it has over 80%, the cross-section length of hollow and if it has less 80%, the cross-section area of hollow is applied, respectively. Conclusion: This study indicated that the test method of fineness shows high reliability. Heat insulating fibers which have high evenness shows narrow variations(5/% or less, only CV 25%) irrespectively under different testing equipment or institute. Based ons the results, we have suggest the standardization of test methods for fineness by microscope method and produced the registration of Group Standard in Korean Standards Association.