• Title/Summary/Keyword: Hold time

Search Result 626, Processing Time 0.026 seconds

Behaviors of surface micro-crack of 304 stainless steel at elevated temperature (304스테인리스강의 고온표면미소 균열의 거동에 관한 기초적 연구)

  • 서창민;이정주;김영호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1320-1326
    • /
    • 1988
  • This paper deals with the behavior of surface crack growth and the characteristics of surface micro-crack distribution under creep and creep-fatigue with 1 min. and 10 min. of load holding times at 593.deg.C, in air. The test specimen is a plate type with a small artificial defect of type 304 the small defect has been carried out by the surface replica method and optical microphotography. The experimental results have been interpreted from the view-point of fracture mechanics. It can be concluded that the longer the hold time the longer the total life time. Most of surface micro-cracks initiate at grain boundaries before the specimen reaches 20% of its total life time, a few of them lead to fracture by coalescence with the main crack.

Discretization of Nonlinear Systems with Delayed Multi-Input VIa Taylor Series and Scaling and Squaring Technique

  • Yuanliang Zhang;Chong Kil To
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1975-1987
    • /
    • 2005
  • An input time delay always exists in practical systems. Analysis of the delay phenomenon in a continuous-time domain is sophisticated. It is appropriate to obtain its corresponding discrete-time model for implementation via digital computers. In this paper a new scheme for the discretization of nonlinear systems using Taylor series expansion and the zero-order hold assumption is proposed. The mathematical structure of the new discretization method is analyzed. On the basis of this structure the sampled-data representation of nonlinear systems with time-delayed multi-input is presented. The delayed multi-input general equation has been derived. In particular, the effect of the time-discretization method on key properties of nonlinear control systems, such as equilibrium properties and asymptotic stability, is examined. Additionally, hybrid discretization schemes that result from a combination of the scaling and squaring technique (SST) with the Taylor series expansion are also proposed, especially under conditions of very low sampling rates. Practical issues associated with the selection of the method's parameters to meet CPU time and accuracy requirements, are examined as well. A performance of the proposed method is evaluated using a nonlinear system with time delay maneuvering an automobile.

Improving a Digital Redesign for Time-Varying Trackers (시변 추종제어기를 위한 디지털 재설계의 개선)

  • Song, Hyun-Seok;Lee, Ho-Jae;Kim, Do-Wan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.289-294
    • /
    • 2011
  • Digital redesign is yet another efficient tool to convert a pre-designed analog controller into a sampled-data one to maintain the analog closed-loop performance in the sense of state matching. A rising difficulty in developing a digital redesign technique for trackers with time-varying references is the unavailability of a closed-form discrete-time model of a system, even if it is linear time-invariant. A way to resolve this is to approximate the time-varying reference as a piecewise constant one, which deteriorates the state matching performance. Another remedy may be to decrease a sampling period, which however could numerically destabilize the optimization-based digital redesign condition. In this paper, we develop a digital redesign condition for time-varying trackers by approximating the time-varying reference through a triangular hold and by introducing delta-operated discrete-time models. It is shown that the digitally redesigned sampled-data tracker recovers the performance of the pre-designed analog tracker under a fast sampling limit. Simulation results on the formation flying of satellites convincingly show the effectiveness of the development.

Easy and Fast Stitch out Method with a Traction Nylon in Pediatric Sutured Wound (당김줄을 이용한 소아 열상 환부의 쉽고 빠른 발사 방법)

  • Lee, Yoon-Jung;Lee, Kyung-Suk;Kim, Jun-Sik;Kim, Nam-Gyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.199-201
    • /
    • 2010
  • Purpose: Except for continuous suture in skin layer, stitching out in facial laceration, we have to hold each knots up and cut the knots by No. 11 blade or small scissors. However, we often have difficulty in stitching out the knots on children who do not cooperate well. Therefore we introduce an easy and fast stitch out method of pediatric lacerations. Methods: From January to May 2009, we studied 15 pediatric patients (mean age 5.6 years old) who had facial laceration on face or underwent any surgery on operation room. For easy stitch out, we left the one string of the first knot long enough to extend at the opposite end of laceration site. And then the extended string was fixed to skin using Steri-strip. Next we do simple interrupted suture including the extended traction nylon string inside the knot. Through this method, we can stitch out all knots simply by lifting up the traction nylon needless to hold the each knot one by one. Results: Until stitching out, the traction nylon was just right position and there was no normal tissue injury during stitch out all knots. Patients were satisfied with the short stitch out time. Conclusion: By using the traction nylon on pediatric laceration suture, we can stitch out all the knots with no normal tissue injury in less time.

Design of a Timing Error Detector Using Built-In current Sensor (내장형 전류 감지회로를 이용한 타이밍 오류 검출기 설계)

  • Kang, Jang-Hee;Jeong, Han-Chul;Kwak, Chol-Ho;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.12-21
    • /
    • 2004
  • Error control is one of major concerns in many electronic systems. Experience shows that most malfunctions during system operation are caused by transient faults, which often mean abnormal signal delays that may result in violations of circuit element timing constraints. This paper presents a novel CMOS-based concurrent timing error detector that makes a flip-flop to sense and then signal whether its data has been potentially corrupted or not by a setup or hold timing violation. Designed circuit performs a quiescent supply current evaluation to determine timing violation from the input changes in relation to a clock edge. If the input is too close to the clock time, the resulting switching transient current in the detection circuit exceeds a reference threshold at the instant of the clock transition and an error is flagged. The circuit is designed with a $0.25{\mu}m$ standard CMOS technology at a 2.5 V supply voltage. The validity and effectiveness are verified through the HSPICE simulation. The simulation results in this paper shows that designed circuit can be used to detect setup and hold time violations effectively in clocked circuit element.

  • PDF

Physicochemical Properties of Freeze-dried Corn Starch Sponge Matrix (동결 건조된 옥수수 전분 스펀지 매트릭스의 이화학적 특성)

  • Han, Kyung-Hoon;Kim, Doh-Hee;Song, Kwan-Yong;Lee, Kye-Heui;Yoon, Taek-Joon;Yang, Sung-Bum;Lee, Seog-Won
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.3
    • /
    • pp.419-427
    • /
    • 2010
  • The focus of the current study was to investigate the physicochemical properties of a corn starch-sponge matrix prepared at a low concentration below gel forming by freeze-drying. The effect of variables(starch concentration, heating temperature, and heating hold time) on the physicochemical properties of the samples was analyzed by response-surface methodology. Regression models on the properties of samples such as hardness, springiness, and water solubility index(WSI) showed high correlation coefficients(r>0.95) and significant F values, but regression models for the other properties(swelling power, apparent viscosity, reducing sugar content, and digestibility) showed them to have relatively low significance. Sample hardness of sample showed the highest value at condition of $90^{\circ}C$ and 5%, whereas springiness was at a maximum at $130^{\circ}C$ and 5%. Also, at 1% of starch concentration, mechanical properties were greatly decreased as the relative humidity increased, compared with the 3% and 5%, especially in the hardness of samples. The WSI showed an increasing trend with heating temperature regardless of starch concentration. Overall, the physicochemical properties of freeze-dried corn starch-sponge matrix were influenced much more by starch concentration and heating temperature than by heating hold time. The results of this study show that the basic properties of freeze-dried corn starch-sponge matrix can be used for the specific food applications or as a functional material for its stability.

Advanced Abdominal MRI Techniques and Problem-Solving Strategies (복부 자기공명영상 고급 기법과 문제 해결 전략)

  • Yoonhee Lee;Sungjin Yoon;So Hyun Park;Marcel Dominik Nickel
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.345-362
    • /
    • 2024
  • MRI plays an important role in abdominal imaging because of its ability to detect and characterize focal lesions. However, MRI examinations have several challenges, such as comparatively long scan times and motion management through breath-holding maneuvers. Techniques for reducing scan time with acceptable image quality, such as parallel imaging, compressed sensing, and cutting-edge deep learning techniques, have been developed to enable problem-solving strategies. Additionally, free-breathing techniques for dynamic contrast-enhanced imaging, such as extra-dimensional-volumetric interpolated breath-hold examination, golden-angle radial sparse parallel, and liver acceleration volume acquisition Star, can help patients with severe dyspnea or those under sedation to undergo abdominal MRI. We aimed to present various advanced abdominal MRI techniques for reducing the scan time while maintaining image quality and free-breathing techniques for dynamic imaging and illustrate cases using the techniques mentioned above. A review of these advanced techniques can assist in the appropriate interpretation of sequences.

The Effect of Part-time Hotel Cuisiniers' Labor Environment and Organizational Commitment on Their Job Satisfaction (비정규직 호텔조리사의 직무환경과 조직 몰입이 직무만족도에 미치는 영향)

  • Park, Kwang-Yong;Jun, Hwa-Jin
    • Culinary science and hospitality research
    • /
    • v.13 no.2
    • /
    • pp.69-80
    • /
    • 2007
  • The purpose of this study is that problems caused by labor environment of cuisiniers in hotels need to be considered and studies regarding a part-time cuisinier in a special-grade hotel need to be conducted. This study analyzes the influence of labor conditions and organizational commitment of a part-time hotel cuisinier on duty satisfaction. It consists of two parts: a research based on the review of the literature and empirical study methods. The method of human resource management in hotels such as treatment of a part-time cuisinier in a special-grade hotel and the way of management as a result of an empirical study are proposed. First, as a result of conducting research on duty satisfaction to part-time cuisinier, most of them are highly satisfied with their duty regardless of their age and academic backgrounds. Second, men hold a majority; woman staffs tent to have a had time working overtime considering the situation that hotels run for 24 hours. That is the main reason why less woman staffs work in hotels than man staffs do. Part-time staffs would like to work consistently after they get upgraded to a regular worker. Forth, it is considered to break down into detailed sectors and speciality is highly demanded.

  • PDF

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.