• 제목/요약/키워드: Histomorphometric study

검색결과 230건 처리시간 0.024초

THE HISTOMORPHOMETRIC STUDY ON THE HEALING PROCESS OF A MANDIBULAR FRACTURE IN THE STREPTOZOTOCIN-INDUCED DIABETIC RATS (스트렙토조토신으로 유도된 당뇨백서의 하악골 골절 치유에 관한 조직형태계측학적 연구)

  • Kang, Hee-Jea;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Kim, Jong-Ryoul;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권3호
    • /
    • pp.250-261
    • /
    • 2006
  • Diabetes mellitus, as a major health problem for the elderly, is associated with an extensive list of complications involving nearly every tissue in the body and has been shown to alter the properties of bone and impair fracture healing in both human and animals. The objective of this study was to examine the healing process of a mandibular fracture in the streptozotocin-induced rats histomorphometrically and histologically. A standardized fracture model was chosen and based on blood-glucose value at the time of surgery. A total of 11-weeks old 36 rats were divided into 2 groups; One is a streptozotocin-induced diabetic group and the other is a non-diabetic group. All was fractured experimentally. Three animals from each group were killed 1, 2, 4, 6, 8 and 12 weeks after fracture and specimens were processed undecalcified for quantitative bone histomorphometric and histologic studies. The diabetic group showed a significant decrease of histomorphometry-based parameter including trabecular bone volume, trabecular thickness in comparison to the non-diabetic rat. This was confirmed histologically. In conclusion, this study suggests that in streptozotocin-induced diabetics, the healing process of bone fracture was impaired and delayed about 2-3 weeks comparing to non-diabetics.

Comparison between Resonance Frequency and Histomorphometric Measurements of Mandibular Implants in Beagle Dogs (비글견의 하악골에 식립된 임플랜트에 대한 공진주파수와 조직계측분석의 비교 연구)

  • Kim, Woo-Young;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제19권4호
    • /
    • pp.291-296
    • /
    • 2003
  • The use of resonance frequency analysis (RFA) provides a possibility to clinically measure implant stability and osseointegration. The implant stability quotient (ISQ) value of RFA is well known that influenced by effective abutment length and stiffness of the implant in the surrounding tissues. Among these factors stiffness is not accurately defined histologically yet. And the purpose of this study was to find the histolgical relationship of RFA. 17 implants in 3 beagle dogs were used for this study. Among these implants 10 were survived for 7 months, 4 were survived for 3 months and 3 were immediate status after placement. Resonance frequency analyses were conducted and the dogs were sacrificed. Percentage of the bone to implant contact (BIC) in the interface, percentage of the mineralized bone (bone area) within the threads of the implant, and marginal bone level were measured under light microscopy. The correlation between resonance frequency and histomorphometric measurements were analysed and following results were obtained. 1. There was statistically significant correlation between ISQ value and BIC on healed implants. But ISQ value and BIC of all implants were not significantly correlated. (P<0.01) 2. Significant correlation between ISQ value and bone area was not found in this study. 3. There was statistically significant correlation between ISQ value and marginal bone level on all implants as well as on healed implants. (P<0.01).

Study of bone healing pattern in extraction socket after application of demineralized dentin matrix material (자가치아 뼈 이식재의 발치와내 이식 후 골 치유 양상에 관한 연구)

  • Chung, Jae-Ho;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권5호
    • /
    • pp.365-374
    • /
    • 2011
  • Introduction: Research on dental bone graft material has been actively conducted. Recently, demineralized dentin matrix material has been developed and introduced. This study examined the effect of demineralized dentin matrix material on bone healing. Subjects and Methods: The patients who received no treatment after extraction were used as the control group and patients who underwent demineralized dentin matrix material application in the extraction socket after extraction were used as the experimental group. Panorama radiography was performed at the baseline and at 3.5 months after graft material placement and CT was taken at 3.5 months after graft material placement for a radiologic evaluation. Bony tissue specimens were collected from the alveolar crest in the middle of the extraction socket using a 2 mm trephine bur after 3.5 months for the histology and hostomorphometric study. Results: 1. On the panoramic view, a higher bone density was observed in the subject group. 2. On the panoramic view, the bone density increased significantly in the extraction socket, from the baseline to 3.5 months: a 7 and 10 gray-level scale was observed in the control and experimental group, respectively (P<0.05). 3. The CT view evaluation at 3.5 months revealed significantly higher bone density in the subject group than the control group (P<0.05). 4. The histological findings showed more active new bone and lamellar bone formation in the subject group. Dentin with osteoinduction ability and enamel with osteoconduction ability appeared. 5. On histomorphometric analysis, the subject group showed significantly more new bone, lamellar bone area and lower soft tissue area (P<0.05). The difference between the groups was significant (P<0.05). Conclusion: Bone healing was improved after the application of demineralized dentin matrix material and there was active new bone and lamellar bone formation.

Effectiveness of autogenous tooth bone used as a graft material for regeneration of bone in miniature pig (미니피그에서 자가치아뼈 이식의 골형성 효과에 대한 연구)

  • Jeong, Hye-Rin;Hwang, Ju-Hong;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권5호
    • /
    • pp.375-379
    • /
    • 2011
  • Introduction: This study examined the effect of autogenous tooth bone used as a graft material for bone regeneration in an artificial bony defect of minipigs. Materials and Methods: Four healthy minipigs, weighing approximately 35-40 kg, were used. Four standardized artificial two-walled bony defects, 5 mm in length and depth, were made on the bilateral partial edentulous alveolar ridge on the mandible of minipigs, and autogenous tooth bone was augmented in the right side as the experimental group. On the other hand, only alloplastic bone graft material HA was grafted with the same size and manner in the left side as the control group. All minipigs were sacrificed at 4 weeks after a bone graft and evaluated histologically by Haematoxylin-eosin staining. The specimens were also evaluated semi-quantitatively via a histomorphometric study. The percentage of new bone over the total area was evaluated using digital software for an area calculation. Results: All specimens were available but one in the left side (control group) and two in the right side (experimental group) were missing during specimen preparation. The amount of bone formation and remodeling were higher in all experimental groups than the control. The mean percentage area for new bone in the experimental and control groups was $43.74{\pm}11.96%$ and $30.79{\pm}2.93%$, respectively. Conclusion: Autogenous tooth bone is a good alternative to autogenous bone with the possible clinical feasibility of an autogenous tooth bone graft in the reconstruction of bony defects.

Histomorphometric analysis of an immediate non-functional loaded implant in dogs

  • Ha, Jeong-Wan;Kim, Su-Gwan;Kim, Hak-Hyun;Moon, Seong-Yong;Lim, Sung-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권1호
    • /
    • pp.90-94
    • /
    • 2008
  • The purpose of this study was to investigate the effects of immediate non-functional loading by analyzing histomorphology around the implant tissues in dogs. Five eight- to nine-month-old full-grown dogs weighing around 12 kg were used in the study. Group I (control group) comprised those in which delayed loading was applied to the right side of the mandible, and Group II (experimental group) consisted of dogs in which immediate loading was performed on the left side of the mandible. Resorbable blast media (RBM)-treated double-threaded US III implants measuring 3.5 mm in diameter and 11 mm long were used in the study. Each animal received four implants in each group, for a total of 40 implants. Cemented type abutments were used after implantation. An 8-week period was allowed for bone healing and an abutment was placed after exposing the periosteum for loading. An implant sample was obtained from bone blocks taken when the dogs were killed at 16 weeks after loading. A Mann-Whitney U-test was performed to evaluate statistical significance. Student's t-test was used for the histological evaluation. The bone formation ratio in Groups 1 and 2 was 88.23 and 86.41%, respectively. No significant difference in new bone formation was observed in the two groups. As no significant difference was seen in new bone formation between the delayed and immediate loading groups, early loading might be possible after implant placement.

The BMPs expression and histomorphometric study of ${\beta}-TCP$ / rhBMP-2 Grafting on the rabbit cranial bone defects

  • Lim, Byung-Sup;Jeon, Jae-Yoon;Park, Chang-Joo;Im, Jae-Jung;Hwang, Kyung-Gyun;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권1호
    • /
    • pp.49-58
    • /
    • 2008
  • Objective: The Purpose of the study was to investigate the bone morphogenic protein expression of rhBMP-2(recombinant human bone morphogenic protein-2) as singnaling molecule and ${\beta}-TCP$(Tricalcium phosphate) as a bone substitute and carrier medium of rhBMP-2. Materials and Methods: 16 rabbits divided into 2 group of each 8 rabbit. Two standardized bone defect, round bilateral defect was made in the cranium of the 8 rabbit of first group, and was grafted with $150{\sim}500{\mu}m$ diameter ${\beta}-TCP$ 0.25g in one side, which was soaked with rhBMP-2, and autogenous bone was grafted on another side as a positive control. Second group of 8 rabbit, only ${\beta}-TCP$ was grafted with same size and same manner. After 2, 4, 8, and 12 weeks, specimen was taken for microscopic immunohiostochemical and histomorphometric analysis. Result: Grafting ${\beta}-TCP$ with rhBMP show the early formation of the bone regenerative factor (BMP-4) and more quantity of new bone formation than only use of ${\beta}-TCP$ (8,12 week), even show less new bone formation than autogenous bone. Conclusion : The experimental study result that ${\beta}-TCP$ graft combination with rhBMP-2 as a delivery system is an effective with osteoinductive capacity and biodegradable properties, so that provide clinical availibility of composite use in reconstruction of bony defect.

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Bone Regenerative Effects of Biphasic Calcium Phosphate Collagen, Bone Morphogenetic Protein 2, Mesenchymal Stem Cells, and Platelet-Rich Plasma in an Equine Bone Defect Model

  • Eun-bee Lee;Hyunjung Park;Jong-pil Seo
    • Journal of Veterinary Clinics
    • /
    • 제40권2호
    • /
    • pp.85-92
    • /
    • 2023
  • Fractures in the horse industry are challenging and a common cause of death in racehorses. To accelerate fracture healing, tissue engineering (TE) provides promising ways to regenerate bone tissues. This study aimed to evaluate the osteogenic effects of biphasic calcium phosphate collagen (BCPC) graft, bone morphogenetic protein 2 (BMP2), mesenchymal stem cell (MSC), and platelet-rich plasma (PRP) treatments in horses. Four thoroughbred horses were included in the study, and, in each horse, three cortical defects with a diameter of 5 mm and depth of 10 mm were formed in the third metacarpal bones (MC) and metatarsal bones (MT). The defects were randomly assigned to one of six treatment groups (saline, BCPC, BMP2, MSC, PRP, and control). Injections of saline, BMP2, PRP, or MSCs were made at 1, 3, and 5 weeks after defect surgery. Bone regeneration effects were assessed by radiography, quantitative computed tomography (QCT), micro-computed tomography (μCT), histopathological, and histomorphometric evaluation. The new bone ratio (%) in the histomorphometric evaluation was higher in the BMP2 group than in the control and saline groups. Radiographic and QCT values were significantly higher in the BCPC groups than in the other groups. QCT values of the BMP2 group were significantly higher than in the control and saline groups. The present study demonstrated that BCPC grafts were biologically safe and showed osteoconductivity in horses and the repeated injections of BMP2 without a carrier can be simple and promising TE factors for treating horses with bone fractures.

Histomorphometric Analysis on Bone Formation Effect of Beta-tricalciumphosphate around Dental Implants in Rabbit Mandibular Body: Pilot Study (토끼의 하악골체부에 식립된 임플란트 주위에서 Beta-tricalciumphosphate 골이식재의 골형성효과에 대한 조직계측학적 연구)

  • Pyun, Young-Hoon;Kim, Il-Kyu;Cho, Hyun-Young;Ju, Sang-Hyun;Jung, Bum-Sang;Pae, Sang-Pill;Cho, Hyun-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권5호
    • /
    • pp.294-301
    • /
    • 2013
  • Purpose: The purpose of this study is to assess the effectiveness of beta-tricalciumphosphate (${\beta}$-TCP) as a bone graft material on new bone formation and regeneration of mandible bone defect around dental implants. Methods: Both mandibular sites of ten rabbits were exposed. The experimental subjects were divided into two groups. Rabbits in the control group (right site of the mandible) had dental implants around cortical bone defects, without treatment, while, in the experimental group (left site of the mandible), ${\beta}$-TCP was grafted into the bone defect around the implant. Rabbits were sacrificed after one, two, three, four, and eight weeks, and histomorphometric evaluation and analysis of the bone implant contact rate were performed using an optical microscope. Results: Bone formation rates in the experimental group were greater than those in the control group from one to eight weeks, and percentages of implant surface contacted to bone were greater in the experimental group than in the control group from three weeks after implantation. Conclusion: These results suggest that the bone formation activity around dental implants was increased by osteoconduction activity of ${\beta}$-TCP.

HISTOLOGIC COMPARATIVE STUDY ON THE BONE-IMPLANT INTERFACE OF HYDROXYLAPATITE AND TITANIUM PLASMA SPRAY COATED IMPLANTS (Hydroxylapatite 및 Titanium Plasma Spray 피복임프란트와 골조직 계면의 조직학적 비교 연구)

  • Cho, Ju-Oh;Song, Kwang-Yeob;Park, Charm-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제33권3호
    • /
    • pp.492-516
    • /
    • 1995
  • This study evaluated the responses of mandibular bones of mongrel dogs to loaded hydro xylapatite(HA) and titanium plasma spray(TPS) coated endosseous dental implants, using unloaded ones as the control group. after HA and TPS coated implants were implanted, their bone reactions with vital bones have been observed with light and scanning electron microscope(SEM) at the three periods of the 4th, 12th and 20th week. These reactions have been also compared in a histomorphometric method. The elemental distribution state of implants and the interface neighboring bone tissues have been measured with the energy dispersive analysis of X-rays(EDAX). The following results were obtained ; 1. The light microscopic analysis showed osseointegration in both the control group and the occlusal force loaded group ; Its degree was shown to be higher in the long-maintained and occlusal force groups. 2. The SEM analysis showed that both groups had osseointegration, In the case of TPS-coated implants, the coated layer was divided on the bone interface. In the case of HA-coated implants, there appeared a division between the metal and coated interface. 3. In the histomorphometric analysis, the measured ratio contaction bone of TPS-coated implants was $70{\pm}19$% in the case of no occlusal force ; it was $84{\pm}13$% in the case of occlusal force. The measured ratio contacting bone of HA-coated implants was $75{\pm}18$% in the case of no occlusal force ; it was $94{\pm}9$% in the case of occlusal force. However, there was no significant difference statistically(p>0.05). 4. Both groups showed that the ratio of calcium and phosphorous increased more in the bone tissues than on the bone to implant interface.

  • PDF