• Title/Summary/Keyword: Hip surgery

Search Result 275, Processing Time 0.019 seconds

Stenotrophomonas maltophilia Periprosthetic Joint Infection after Hip Revision Arthroplasty

  • Valentino Latallade;Carlos Lucero;Pablo Slullitel;Martin Buttaro
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.142-146
    • /
    • 2023
  • Stenotrophomonas maltophilia, a well-established opportunistic bacterium, primarily impacts healthcare settings. Infection of the musculoskeletal system with this bacterium is rare. We report on the first known case of hip periprosthetic joint infection (PJI) caused by S. maltophilia. The potential for development of a PJI caused by this pathogen should be considered by orthopaedic surgeons, particularly in patients with multiple severe comorbidities.

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

Transient osteoporosis of the hip with a femoral neck fracture during follow-up: a case report

  • Yusuke Tabata;Shuhei Matsui;Masabumi Miyamoto;Koichiro Omori;Yoichiro Tabata;Tokifumi Majima
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.212-217
    • /
    • 2023
  • We report a case of transient osteoporosis of the hip with a femoral neck fracture found during follow-up. A 53-year-old man presented with left hip pain without trauma. The pain did not improve after 2 weeks and he was brought to our hospital by ambulance. Magnetic resonance imaging (MRI) of the left hip joint showed diffuse edema in the bone marrow, which was identified by low signal intensity on T1-weighted images, high signal intensity on T2-weighted images, and increased signal intensity on short tau inversion recovery. This edema extended from the femoral head and neck to the intertrochanteric area. He was diagnosed with transient osteoporosis of the left hip. Rest gradually improved his pain; however, 3 weeks later, his left hip pain worsened without trauma. X-ray, computed tomography, and MRI results of the hip joint demonstrated a left femoral neck fracture, and osteosynthesis was performed. Differential diagnoses included avascular necrosis of the femoral head, infection, complex regional pain syndrome, rheumatoid arthritis, leukemia, and other cancers. Transient osteoporosis of the hip generally has a good prognosis with spontaneous remission within a few months to 1 year. However, a sufficient length of follow-up from condition onset to full recovery is necessary to avoid all probable complications such as fractures.

Remaining Loose Bodies after Arthroscopic Surgery Including Extensive Capsulectomy for Synovial Chondromatosis of the Hip

  • Lee, Young-Kyun;Moon, Kyung Ho;Kim, Jin-Woo;Hwang, Ji Sup;Ha, Yong-Chan;Koo, Kyung-Hoi
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.393-397
    • /
    • 2018
  • Background: The purpose of our study was to evaluate the usefulness of hip arthroscopy including extensive capsulectomy for synovial chondromatosis of the hip. Methods: From 2008 to 2016, 13 patients with synovial chondromatosis of the hip were treated with arthroscopic removal of loose bodies and synovectomy using three arthroscopic portals. An extensive capsulectomy was performed to allow the remaining loose bodies to be out of the extracapsular space, and the excised capsule was not repaired. All patients were assessed by clinical scores and the radiographs were reviewed to determine whether the remaining loose bodies disappeared at the last follow-up. Results: Eight men and two women were followed up for a minimum of 1 year (mean, 3.8 years; range, 1 to 6.8 years) after hip arthroscopy. Clinical outcomes such as modified Harris hip score, University of California Los Angeles score, and Western Ontario and McMaster Universities Osteoarthritis Index score improved at the last follow-up. Although seven hips had remaining loose bodies after arthroscopic surgery, the remaining loose bodies disappeared in five hips (71.4%) at the last follow-up. Conclusions: Arthroscopic surgery was useful to treat synovial chondromatosis of the hip. In spite of limited removal of loose bodies, arthroscopic procedures including extensive capsulectomy could be effective for the treatment of synovial chondromatosis of the hip.

Bilateral Asymmetric Traumatic Dislocation of the Hip Joint

  • Park, Hee Gon;Yi, Hyung Suk;Han, Kyoo Hong
    • Journal of Trauma and Injury
    • /
    • v.31 no.1
    • /
    • pp.43-50
    • /
    • 2018
  • Traumatic hip joint dislocations account for 2-5% of total joint dislocations. Bilateral asymmetric hip joint dislocation with anteriorly and posteriorly dislocation is an even more rare case because it was according to G. Loupasis reported in 11 cases only since 1879. We want to report 2 cases of bilateral asymmetric hip joint dislocation with unilateral acatabulum fracture which happened in our hospital. Bilateral asymmetric dislocation of hip joint accompanied by unilateral fracture of acetabulum is a very rare case so statistical verification cannot be done. However, close examinations are required at early treatment and follow-up because the patterns of dislocation and fracture of hip joint are variable and an orthopedic emergent condition and several complications may occur at both hip joints.

Effect of Sarcopenia on Postoperative Mortality in Osteoporotic Hip Fracture Patients

  • Kim, You Keun;Yi, Seung Rim;Lee, Ye Hyun;Kwon, Jieun;Jang, Seok In;Park, Sang Hoon
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.227-233
    • /
    • 2018
  • Background: Few studies have investigated the effects of sarcopenia on postoperative outcomes including mortality rates following surgery for osteoporotic hip fractures. The purpose of the present study was to determine the prevalence of sarcopenia and the relationship between sarcopenia and 1- and 5-year mortality rates in a consecutive series of patients with osteoporotic hip fractures. Methods: Among patients who underwent hip surgery for osteoporotic hip fractures, this study included 91 patients subjected to abdominal computed tomography within 1 year of hip surgery. We defined sarcopenia using sex-specific cut-off points for the skeletal muscle index at the level of the third lumbar vertebra. All patients were divided into 2 groups according to the presence or absence of sarcopenia and the 1- and 5-year mortality rates were compared. To confirm factors affecting mortality in addition to sarcopenia, we examined patient age, sex, American Society of Anesthesiologists grade, location of fracture, type of surgery, and bone mineral density. Results: The 1- and 5-year mortality rates were 20.9% and 67.2%, respectively. Among the 45 patients with sarcopenia, the 1- and 5-year mortality rates were 22.2% and 82.7%, respectively. Of the 46 patients without sarcopenia, the 1- and 5-year mortality rates were 19.6% and 52.7%, respectively. Results of the Kaplan-Meier analysis showed that sarcopenia did not affect the 1-year mortality rate (P=0.793), but had a significant effect on the 5-year mortality rate (P=0.028). Both perioperative sarcopenia (P=0.018) and osteoporosis (P=0.000) affected the 5-year mortality rate. Conclusions: Sarcopenia increases the risk of 5-year mortality in patients with osteoporotic hip fractures.

One-stage Hip Reconstruction for Developmental Hip Dysplasia in Children over 8 Years of Age

  • Qadir, Irfan;Ahmad, Saeed;Zaman, Atiq uz;Khan, Chirag Muhammad;Ahmad, Shahzad;Aziz, Amer
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.260-268
    • /
    • 2018
  • Purpose: This study was performed to assess the clinical and radiological outcomes following one-stage hip reconstruction, consisting of open reduction femoral shortening and pelvic osteotomy, for neglected developmental dislocation of the hip (DDH). Materials and Methods: This is a retrospective analysis of 77 hips in 65 patients (46 females and 19 males; 12 had bilateral dislocations), operated at a Ghurki Trust Teaching Hospital in Pakistan between 2013 and 2015. The average age at surgery was $11.02{\pm}3.43$ years. According to the Tonnis classification, there were 10, 14, 22, and 31 patients in grades 1, 2, 3, and 4, respectively. The pelvic procedure utilized in this study was triple osteotomy (47 hips) followed by double and Salter osteotomy (18 and 12 hips, respectively). Postoperative evaluations were conducted using the modified MacKay's scoring system (functional outcomes) and Severin's scoring method (radiological assessment). Results: Postoperatively, there were 38 (49.4%), 19 (24.7%), 14 (18.2%), and 6 (7.8%) hips in Severin grade I, II, III and IV, respectively. According to the modified McKay criteria, there were 22 hips (28.6%) in excellent condition, 44 (57.1%) in good condition, 9 (11.7%) in fair condition and 2 (2.6%) in poor condition. Both patients with poor outcomes had an unstable, painful hip with evidence of avascular necrosis of the femoral head. Conclusion: Based on the results presented here, we recommend the single stage procedure of open reduction, femoral shortening and pelvic osteotomy for treatment of DDH in older children with good to excellent functional and radiological outcomes.

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

The Impact of Surgical Timing of Hip Fracture on Mortality: Do the Cause and Duration of Delay Matter?

  • Jaiben George;Vijay Sharma;Kamran Farooque;Samarth Mittal;Vivek Trikha;Rajesh Malhotra
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.206-215
    • /
    • 2023
  • Purpose: Delay in performance of hip fracture surgery can be caused by medical and/or administrative reasons. Although early surgery is recommended, it is unclear what constitutes a delayed surgery and whether the impact of delayed surgery can differ depending on the reason for the delay. Materials and Methods: A total of 269 consecutive hip fracture patients over 50 years of age who underwent surgery were prospectively enrolled. They were divided into two groups: early and delayed (time from reaching the hospital to surgery less than or more than 48 hours). Patients were also categorized as fit or unfit based on anesthetic fitness. One-year mortality was recorded, and regression analyses were performed to assess the impact of delay on mortality. Results: A total of 153 patients (56.9%) had delayed surgery with a mean time to surgery of 87±70 hours. A total of 115 patients (42.8%) were considered medically fit to undergo surgery. No difference in one-year mortality was observed between patients with early surgery and those with delayed surgery (P=0.854). However, when assessment of the time to surgery was performed in a continuous manner, mortality increased with prolonged time to surgery, particularly in unfit patients, and higher mortality was observed when the delay exceeded six days (fit: P=0.117; unfit: P=0.035). Conclusion: The effect of delay on mortality was predominantly observed in patients who were not considered medically fit, suggesting that surgical delays might have a greater impact on patients with medical reasons for delay.

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.