• Title/Summary/Keyword: Hip rotation

Search Result 188, Processing Time 0.023 seconds

Effect of Cross-legged Sitting Posture on Joint Range of Motion: Correlation with Musculoskeletal Symptoms and Facial Asymmetry

  • Shin, Yeong hui
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.255-266
    • /
    • 2022
  • Purpose: This study sought to study the effects of cross-legged sitting posture on joint motion. It also examined the correlation between the changes in the joint range of motion, musculoskeletal symptoms, and facial asymmetry. Methods: The Acumar Digital Inclinometer (Lafayette Instrument Company, USA) was used to measure the range of motion (ROM). We measured the flexion and extension of the cervical, thoracic, and lumbar spine using a dual inclinometer, and measured the ROM of the shoulder and hip joint with a single inclinometer. The Likert scale questionnaire was used to investigate musculoskeletal symptoms and facial asymmetry. Results: The data analysis was performed using the Jamovi version 1.6.23 statistical software. After confirming the normality of the ROM with descriptive statistics, it was compared with the normal ROM through a one-sample t-test. Correlation matrix analysis was performed to confirm the association between facial asymmetry and musculoskeletal symptoms. The result of the one-sample t-test showed a significant increase in the thoracic spine extension and right and left hip external rotation (p<0.001***), while most other joints were restricted. As per the frequency analysis, facial asymmetry was found to be 81.70%. Conclusion: The independent variable, namely cross-legged sitting posture led to an increase in ROM. The study also suggests that facial asymmetry and musculoskeletal symptoms could occur. Therefore, to prevent the increase and limitation of ROM and to prevent the occurrence of facial asymmetry and musculoskeletal symptoms, it is suggested that the usual cross-legged sitting posture should be avoided.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Kinematical Analysis of Swing Motion with Golf Iron Clubs Used by Elite Golfers (우수 골퍼의 아이언 클럽 스윙동작에 대한 운동학적 분석)

  • Kim, Kab-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to provide basic materials for amateur golf players or golf maniacs to learn desirable iron swing motions. This study compared and analyzed the swing motions of iron clubs(3, 6, 9) by using 3-D in three elite golf players. 1. There was no a great difference in the total of swing time by club and the time by phase was nearly similar. 2. There was no a difference in the change in a head location at address and impact by club. 3. The angle change in a right knee joint was similar by club except the difference according to the length of the club. 4. There was a subtle difference in hip rotation angle by club. 5. In each club, the same rotation angle of shoulder joint at address and impact motions contributed to accurate swing, and the maintenance of more than $90^{\circ}$ of shoulder rotation angle in top swing increased swing rotation. 6. Although subtle, the forward angle of upper body was increased with a shorter club. $30-36^{\circ}$ of forward angle of upper body was maintained at address, top swing, and impact motions.

The Effect of Genu Valgum on the Body Mass Index, Moment of Lower Limb Joints, Ground Reaction Force (신체질량지수, 하지관절의 모멘트, 지면반발력이 무릎외반슬에 미치는 영향)

  • Lee, Yong-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.257-263
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effect of genu valgum on the body mass index, movement of lower limb joints, and ground reaction force. Methods : Gait patterns of 30 college students with genu valgum were analyzed and the static Q angle of the femur was measured for selecting genu valgum of the subjects. To analyze the kinetic changes during walking, the six-camera Vicon MX motion analysis system was used. The subjects were asked to walk 12 meters using the more comfortable walking method for walking. After they walked 12 meters more than 10 times, their most natural walking patterns were chosen three times and analyzed. Results : As a result of measuring a relationship between genu valgum and Q-angle, as the Q-angle increases, it showed a genu valgum also increased. Body Mass Index showed a significant difference between the groups was higher in the genu valgum group.(p<.001). The analysis result showed that genu valgum had a significant effect on the internal rotation moment in the hip joint(p<.05). Also, genu valgum had a significant effect on the internal rotation moment of the knee joint(p<.05). The comparative analysis of the Medial-Lateral ground reaction force in the genu valgum group showed a tendency to increase the medial ground reaction force(p<.05). The vertical ground reaction forces of the middle of the stance phase(Fz0) showed a significant increase in genu valgum group(p<.05), in particular the results showed a decrease in the early stance phase(p<.001). Conclusion : In conclusion, the change in body mass is considered to be made by proactive regular exercise for improvement of the genu valgum. In addition, the prevention of the deformation caused by secondary of the genu valgum in this study may be used as an indicator of the position alignment rehabilitation for structural and functional improvements. Applying a therapeutic exercise program for the next lap will require changes in posture alignment.

Analysis of Gait Parameters According to the Clinical Features of Parkinson's Disease Using 3-D Motion Analysis System with Electrogoniometer (3차원 전기측각 보행분석기를 이용한 파킨슨씨병 환자의 임상 양상에 따른 보행 분석)

  • Baek, Hye-Jin;Yoon, Joon-Shik;Kim, Sei-Joo;Lee, Gyu-Ho;Koh, Seong-Beom
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Background: To investigate the differences of locomotor dynamics between Parkinson's disease (PD) patients with tremor dominant symptom and patients with postural instability dominant symptom. Methods: 66 subjects with PD were classified into two subgroups, tremor-dominant group and postural instability and gait disorder group by Unified Parkinson's disease rating scale (UPDRS). The spatial, temporal and electrodynamic gait parameters were recorded automatically using computerized 3-D motion analysis system with electrogoniometer. Results: There was no significant difference in cadence, pelvic tilt range, hip flexion range, knee flexion range and ankle dorsiflexion range. Postural instability and gait disorder group showed decreased gait velocity, short stride length, decreased range of motion in pelvic obliquity, pelvic rotation and ankle plantar flexion. Conclusions: There was meaningful difference in locomotor dynamics between Parkinson's disease(PD) patients with tremor dominant symptom and patients with postural instability dominant symptom.

  • PDF

Development of a Passive Knee Mechanism for Lower Extremity Exoskeleton Robot (근력 지원용 외골격 로봇을 위한 수동형 무릎 관절 메커니즘 개발)

  • Kim, Ho-Jun;Lim, Dong-Hwan;Han, Chang-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.107-115
    • /
    • 2017
  • In this paper, four-bar linkage mechanism for the knee joint is developed which is used in prosthetics. But unlike the prosthetics, the feature of this mechanism is that the instantaneous center of rotation of the four-bar linkages can be moved behind the ground reaction force vector so that it can be passively supported without any external power. In addition, this mechanism is developed similar to the structure of the human knee joint for eliminating the sense of heterogeneity of the wearer. In order to design the mechanism with these two objectives, optimization design process is done using the PIAnO tool and detailed design is carried out through optimized variable values. The developed mechanism is attached to the robot which can assist the hip and ankle joints. In order to verify the operation of the developed knee mechanism, an insole type sensor was attached to the shoes to compare data values before and after wearing the robot. Result data showed that wearer wearing the exoskeleton robot with the knee mechanism was the same value regardless of whether the heavy tool is loaded or not.

Position Control of the Two Links Inverted Pendulum with a Time Varying Load on the Top (상부 시변 부하를 갖는 2축 도립진자의 위치 제어)

  • 이건영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1147-1153
    • /
    • 1999
  • The attitude control of a double inverted pendulum with a periodical disturbance at link top is dealt in this paper. The proposed system is consisted of the double inverted pendulum and a disturbing link; a triple inverted pendulum with two motors. The lower link is hinged on the plate to free for rotation in the vertical plane. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The periodical disturbance can be generated by the additional like attached at the end of link 2 through another DC motor, which is the modeling of a posture for a biped supporting with one leg. The motor for the joint simulates the knee joint(or hip joint) and the disturbance for the legs moving in air. The algorithm for controlling the proposed inverted pendulum which is regarded as a virtual double inverted pendulum with a periodic disturbance, is consisted of a state feedback control and a fuzzy logic controller connected in parallel. The fuzzy controller keeps the center of gravity of the biped within the specified range through the nonlinear feedback compensator. The state feedback control takes over the role to maintain a desired posture regardless the disturbance at the link top. Simulations with a mathematical model and experiments are conducted to show the validity of the proposed controller.

  • PDF

Correlation between Pelvic Angle and the Tibiofemoral Angle in the Genu Varum (내반슬로 인한 대퇴경골각의 변화가 골반경사각에 미치는 영향)

  • Kim, Kyoung-Seok;Ryu, Ji-Mi;Kim, Koh-Woon;Kim, Gwi-Hyun;Jeong, Won-Seok;Lee, Jong-Soo
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • Objectives : The purpose of this study was to investigate the Correlation between Pelvic angle and the Tibiofemoral angle in the Genu varum. Method : Age of All subjects were 20-37 years. 33(male 10, female 23) subjects were assessed by whole spine x-ray and orthogram. The collected data consisted of items on general characteristics, Pelvic Incidence(PI), Pelvic Tilt(PT), Sacral Slope(SS) and Tibiofemoral Angle(TFA) of the subjects. Results : The PI, PT and TFA had a relationship significantly. However, there was no relationship between SS and TFA. Conclusion : The results suggest that TFA is related to PI, PT. Internal rotation due to genu varum of femoral at hip influence that PI and PT increase.

  • PDF

A Case of Atypical Bone Growth after Femur Neck Fracture in the Paraplegic Patient with Trochanteric Sore (대전자부 압박궤양을 가지고 있는 하지마비 환자에서 대퇴골 골절부위에 발생한 비정상적 골증식의 치험례)

  • Yang, Jeong Yeol;Cheon, Ji Seon
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.92-95
    • /
    • 2008
  • Purpose: Heterotopic ossification in pressure sore patients is reported to rarely develop, but once it occurs, it frequently causes joint stiffness and mobilization restriction. The aim of this article is to report our experience of atypical bone growing at femur neck fracture site with chronic, extensive pressure sore in patient with paraplegia secondary to spinal injury. Methods: A 28-year-old male patient presented with atypical bone growth at femur neck fracture site with pressure sore. He had undergone atypical growth bone removal and separation of united iliac bone and femur, and then pressure sore was covered by advanced rotation flap. Results: The patient mobilized hip joint and rode in a wheelchair. Complications such as dehiscence, infection, hematoma and flap necrosis did not occur. Conclusion: We experienced successful correction of atypical bone growth removal and recovery of pressure sore. We report our experience of atypical bone growth of fracture site and the related literature was reviewed.

The Attitude Control of The Double Inverted Pendulum with Periodic Upper Disturbance (주기적인 상부 외란이 인가되는 2축 도립 진자의 자세 제어)

  • Nam, Row-Hyun;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2309-2311
    • /
    • 1998
  • The attitude control of a double inverted pendulum with a periodical disturbance at link top is dealt in this paper. The proposed system is consisted of the double inverted pendulum and a disturbance link. The lower link is hinged on the plate to free for rotation in the vertical plane. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The periodical disturbance can be generated by the additional link attached at the end of link 2 through another DC motor, which is the modeling of a posture for a biped supporting with one leg. The motor for the joint simulates the knee joint(or hip joint) and the disturbance for the legs moving in air. The algorithm for controlling a proposed inverted pendulum is consisted of a state feedback control and a fuzzy logic controller. The fuzzy controller keeps the center of gravity of the biped within the specified range through the nonlinear feedback compensator. The state feedback control takes over the role to maintain a desired posture regardless the disturbance at the link top. In these case, the change of the angle and COG of an upper link is compensated with on-line. Simulations with a mathematical model are conducted to show the validity of the proposed controller.

  • PDF