Hip Resurfacing Arthroplasty after Failure of Tantalum Rod Insertion in Patients with Osteonecrosis of the Femoral Head

  • Yoon Je Cho;Kee Hyung Rhyu;Young Soo Chun;Hyun Gon Gwak
    • Hip & pelvis
    • /
    • 제34권4호
    • /
    • pp.219-226
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the clinical outcomes and efficacy of hip resurfacing arthroplasty (HRA) in patients with osteonecrosis of the femoral head after the failure of porous tantalum rod insertion without rod removal. Materials and Methods: Conversion to hip resurfacing arthroplasty was performed in 10 patients (11 hips) with a mean period of 14.9 months after the primary surgery. The mean follow-up period was 73.7 months. Analysis of pre and postoperative range of motion (ROM), University of California at Los Angeles (UCLA) activity score, modified Harris hip score, and visual analog scale (VAS) pain score was performed. Radiographic analysis of component loosening and osteolysis was performed. Results: The postoperative ROM showed significant improvement (P<0.05), excluding flexion contracture. The modified Harris hip score showed improvement from 65.82 to 96.18, the UCLA score showed improvement from 4.18 to 8.00, and the VAS pain score was reduced from 6.09 to 1.80. All scores showed statistically significant improvement (P<0.05). No component loosening or osteolysis was detected by radiographic analysis. Conclusion: Satisfactory results were obtained from conversion hip resurfacing arthroplasty after failure of porous tantalum rod insertion without rod removal. The findings of this study demonstrate the advantages of HRA, including no risk of trochanteric fracture and no bone loss around the tantalum rod. In addition, the remaining porous tantalum rod provided mechanical support, which reduced the potential risk of femoral neck fracture or loosening. This technique can be regarded as a favorable treatment option.

SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가 (Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT)

  • 김상규;김정열;박민수;조승현;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.3-7
    • /
    • 2014
  • CT를 기반으로 감쇠보정이 시행되는 SPECT/CT 검사에서는 금속 삽입물에 의한 선속경화현상으로 인접한 부위의 과대평가를 유발하며, 영상의 질을 저하시킨다. 이에 대해, 본 연구에서는 인공고관절이 삽입된 팬텀을 이용하여 감쇠보정지도의 매개변수 변화에 따른 금속 인공물이 SPECT/CT 영상에 미치는 영향을 알아보고자 한다. SPECT/CT 장비는 Siemens사의 Symbia T16을 사용하였다. SPECT/PET 팬텀에 인공고관절을 삽입하고, CT영상에서 Bright Streak 영역에 직경 17 mm의 구를 배후방사능 대비 8배가 되도록 Tc-99m을 채웠다. 이후 감쇠보정지도에서 Wide Beam Coefficient[수동모드(0.1~0.9), 자동모드]변화에 따른 열소와 배후방사능의 계수를 측정하였고, 고관절의 유무에 따라 Metal과 Non-Metal의 병소 대 배후방사능 비(Region to Background Ratio, RBR)를 산출 및 비교 분석하였다. 수동모드의 값이 증가할수록 Metal과 Non-Metal의 열소 계수는 증가하는 경향을 나타냈으며, 수동모드 0.4와 0.5에서 두 군과의 열소 계수비가 가장 일치하게 나타났다(수동모드 0.4=1.001, 0.5=0.999). 또한 $RBR^{Metal}$$RBR^{Non-Metal}$의 비는 자동모드에서 1.135이였고, 수동모드 0.4와 0.5에서 통계적으로 유의한 차이를 보이지 않았다(0.4=0.999, 0.5=1.028, p=0.78). 감쇠보정지도에서 Wide Beam Coefficient의 자동모드는 13.52% 과 보정 되는 것을 알 수 있었으며, 수동모드 중 0.4와 0.5에서 인공물에 의한 과 보정을 최소화 할 수 있었다. 이를 활용하여 환자에게 적용하기 위해서는 추가적인 연구가 이루어져야 할 것이며, 고관절전치환술 환자의 인공고관절 주변에서 금속 인공물에 의한 과 보정을 감소시켜 진단능을 향상시킬 수 있을 것으로 사료된다.

  • PDF