• Title/Summary/Keyword: High-temperature design evaluation

Search Result 234, Processing Time 0.025 seconds

Preliminary Thermodynamic Evaluation of a Very High Temperature Reactor (VHTR) Integrated Blue Hydrogen Production Process (초고온가스로 연계 블루수소 생산 공정의 열역학적 분석)

  • SEONGMIN SON
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.3
    • /
    • pp.267-273
    • /
    • 2023
  • As the impacts of global climate change become increasingly apparent, the reduction of carbon emissions has emerged as a critical subject of discussion. Nuclear power has garnered attention as a potential carbon-free energy source; however, the rapidity of load following in nuclear power generation poses challenges in comparison to fossil-fueled methods. Consequently, power-to-gas systems, which integrate nuclear power and hydrogen, have attracted growing interest. This study presents a preliminary design of a very high temperature reactor (VHTR) integrated blue hydrogen production process utilizing DWSIM, an open-source process simulator. The blue hydrogen production process is estimated to supply the necessary calorific value for carbon capture through tail gas combustion heat. Moreover, a thermodynamic assessment of the main recuperator is performed as a function of the helium flow rate from the VHTR system to the blue hydrogen production system.

Development of a 250-W high-power modular LED fish-attracting lamp by evaluation of its thermal characteristics

  • Lee, Donggil;Lee, Kyounghoon;Pyeon, Yongbeom;Kim, Seonghun;Bae, Jaehyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • Recently LED fish-attracting lamps have been more widely used in fisheries as low-cost and high-efficiency fishing gear, and development of long-life high-efficiency lamps is required through the design of LED packages to optimize heat resistance. This study developed an improved LED fish-attracting lamp with excellent heat performance, which was verified using a numerical model. Heat-resistance design factors such as the heat-radiation fin shape, PCB type, and LED chip count were investigated and optimized. Comparison with a commercial 180-W LED fishing lamp showed that the increase in initial temperature was 40% higher than that of the surrounding LED chip because of design errors in contact thermal resistance. The 250-W LED lamp developed in this study has a characteristic with thermal rising in linearly stable according to the heat source. In addition, luminance efficiency was improved by 20-65% by using flow-visualization simulation. A decrease of 45% in total power consumption with a fuel-cost reduction of over 55% can be expected when using these optimized heat release design factors.

Comparative Reliability Analysis of DC-link Capacitor of 3-Level NPC Inverter Considering Mission-Profiles of PV Systems (태양광 시스템의 미션 프로파일 고려한 3-레벨 NPC 인버터의 DC-link 커패시터 신뢰성 비교 분석)

  • Jae-Heon, Choi;Ui-Min, Choi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.535-540
    • /
    • 2022
  • DC-link capacitors are reliability-critical components in a photovoltaic (PV) inverter. Typically, the lifetime of a DC-link capacitor is evaluated by considering the voltage and hot-spot temperature of the capacitor under the specific operating condition of the PV inverter. However, the output of the PV inverter is determined by solar irradiation and ambient temperature, which vary with the seasons; accordingly, the hot-spot temperature of the capacitor also changes. Therefore, the mission profile of the PV system should be considered to effectively evaluate the reliability of the DC-link capacitor. In this study, the reliability of the DC-link capacitor of a three-level NPC inverter is comparatively analyzed with and without considering the mission profiles of the PV system, where two mission profiles recorded in Arizona and Iza are considered. The accumulated damage of the DC-link capacitor is calculated based on the lifetime model by analyzing its thermal loading. Afterward, a reliability evaluation of the DC-link capacitor is performed at the component level and then at the system level by considering all capacitors by means of Monte Carlo analysis. Results reveal the importance of performing a mission-profile-based reliability evaluation during the design of high-reliability PV inverters to achieve the target reliability performance.

Evaluation System of the Thermal Properties of the Exothermic & Insulating Materials (발열 보온재의 특성평가 시스템 구축)

  • Shin, D.Y.;Kim, D.J.;Jun, B.H.;You, B.D.;Kim, N.S.;Oh, S.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.5
    • /
    • pp.356-363
    • /
    • 2008
  • An evaluation system of the thermal properties of exothermic & insulating materials was developed. By measuring the power supply of the induction furnace, the thermal property of exothermic & insulating materials could be evaluated with high reproducibility at elevated temperature of molten steel. The thermal properties of exothermic & insulating materials were affected by mixing condition of raw materials. The effect of main components of exothermic & insulating materials such as metallic aluminum and $Fe_2O_3$ powder on the exothermic and insulating properties was examined. It could be expected to design and develop various exothermic & insulating materials by means of the evaluation system of the thermal properties.

Overview on Thermal Management Technology for High Power Device Packaging (파워디바이스 패키징의 열제어 기술과 연구 동향)

  • Kim, Kwang-Seok;Choi, Don-Hyun;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.2
    • /
    • pp.13-21
    • /
    • 2014
  • Technology for high power devices has made impressive progress in increasing the current density of power semiconductor, system module, and design optimization, which realize high power systems with heterogeneous functional integration. Depending on the performance development of high power semiconductor, packaging technology of high power device is urgently required for efficiency improvement of the device. Power device packaging must provide superior thermal management due to high operating temperature of power modules. Here we, therefore, review critical challenges of typical power electronics packaging today including core assembly processes, component materials, and reliability evaluation regulations.

Design Evaluation of WEDM Based on Deformation Analyses and Axiomatic Design (변형해석 및 공리적 설계에 의한 와이어 방전가공기의 설계평가)

  • Lee, Hyung-Yil;Woo, Sang-Woo;Kim, Joo-Won;Kim, Choong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.572-579
    • /
    • 2001
  • Recent industrial requirements for highly precise shape processing have brought the electric discharge machining (EDM) in great need. High precision in EDM is primarily achieved by high performance controllers. However there exists inherent precision loss due to structural deformation. On this background, we study structural deformation characteristics of wire cut EDM via finite element (FE) analysis and axiomatic design. Two different wire cut EDMs are selected as analysis models. 3D CAD package I-Deas is first used to construct FE models of wire cut EDMs, and then ABAQUS FE code is used for following structural analysis. Pertinency of FE mesh refinement is discussed in terms of ${\eta}-factor$. It is shown that performance accuracy of EDM depends strongly on the structural characteristics. Some design enhancements are suggested in an axiomatic design point of view. Finally we provide weight and temperature induced displacement discrepancies between wire end points as position functions of each subframe.

  • PDF

Development and performance evaluation of a cryogenic blower for HTS magnets

  • Kwon, Yonghyun;Mun, Jeongmin;Lee, Jaehwan;Seo, Geonghang;Kim, Dongmin;Lee, Changhyeong;Sim, Kideok;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.57-61
    • /
    • 2020
  • Cooling by gas helium circulation can be used for various HTS (high temperature superconductor) magnets operating at 20~40 K, and a cryogenic blower is an essential device for circulating gas helium in the cooling system. The performance of the cryogenic blower is determined by various design parameters such as the impeller diameter, the blade number, the vane angle, the volute cross-sectional area, and the rotating speed. The trailing edge angle and the height of impeller vane are also key design factors in determining the blower performance. This study describes the design, fabrication and performance evaluation of cryogenic blower to produce a flow rate of 30 g/s at 5 bar, 35 K gas helium. The impeller shape is designed using a specific speed/specific diameter diagram and CFD analysis. After the fabrication of the cryogenic blower, a test equipment is also developed using a GM cryocooler. The measured flow rates and the pressure differences are compared with the design values at various rotating speeds and the results show a good agreement. Isentropic efficiency is also evaluated using the measured pressures and temperatures.

High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II) (헬륨가스루프 시험용 공정열교환기에 대한 고온구조해석 모델링(II))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1455-1462
    • /
    • 2010
  • PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the helium gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the hightemperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

The Evaluation of Thermal Aging for Insulation Paper with Mineral and Vegetable Oil (광유 및 식물성 절연유에서 절연지의 열적 열화 특성 평가)

  • Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1558-1560
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer (배전용 변압기 절연유의 특성 비교 평가)

  • Lee, Byung-Sung;Park, Young-Keun;Kim, Dong-Myung;Kim, Pil-Hwan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF