• Title/Summary/Keyword: High-temperature design evaluation

Search Result 230, Processing Time 0.024 seconds

Development of a structural integrity evaluation program for elevated temperature service according to ASME code

  • Kim, Nak Hyun;Kim, Jong Bum;Kim, Sung Kyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2407-2417
    • /
    • 2021
  • A structural integrity evaluation program (STEP) was developed for the high temperature reactor design evaluation according to the ASME Boiler and Pressure Vessel Code (ASME B&PV), Section III, Rules for Construction of Nuclear Facility Components, Division 5, High Temperature Reactors, Subsection HB. The program computerized HBB-3200 (the design by analysis procedures for primary stress intensities in high temperature services) and Appendix T (HBB-T) (the evaluation procedures for strain, creep and fatigue in high temperature services). For evaluation, the material properties and isochronous curves presented in Section II, Part D and HBB-T were computerized for the candidate materials for high temperature reactors. The program computerized the evaluation procedures and the constants for the weldment. The program can generate stress/temperature time histories of various loads and superimpose them for creep damage evaluation. The program increases the efficiency of high temperature reactor design and eliminates human errors due to hand calculations. Comparisons that verified the evaluation results that used the STEP and the direct calculations that used the Excel confirmed that the STEP can perform complex evaluations in an efficient and reliable way. In particular, fatigue and creep damage assessment results are provided to validate the operating conditions with multiple types of cycles.

Application methodology of Type 316L stainless steel to a 700℃ heat exchanger (Type 316L 스테인리스강의 700℃ 열교환기에의 적용 방법론)

  • Hyeong-Yeon Lee;Ki-Ean Nam;Yun-Seung Lee;Jaehyuk Eoh
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.75-83
    • /
    • 2024
  • In this study, high temperature design and integrity evaluation methodology have been developed for Type 316L stainless steel air-to-sodium heat exchanger which uses 700℃ sodium as coolant. Currently the only design rules that take creep effects into consideration explicitly for the 316L stainless steel subjected to high temperature in the creep range are French RCC-MRx, where elevated temperature designs are possible around 550℃. Absent design coefficients at high temperature were determined based on the material properties newly determined in previous studies, and high-temperature design evaluation methodologies were developed based on 3D finite element analyses on the 700℃ class heat exchanger. In addition, works were conducted on the web-based design evaluation program of HITEP_RCC-MRx including incorporation of material properties and design coefficients up to 700℃. Methodologies on high temperature design evaluations on Type 316L stainless steel high-temperature heat exchanger were suggested.

Design of type 316L stainless steel 700 ℃ high-temperature piping

  • Hyeong-Yeon Lee;Hyeonil Kim;Jaehyuk Eoh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3581-3590
    • /
    • 2023
  • High-temperature design evaluations were conducted on Type 316L stainless steel piping for a 700 ℃ large-capacity thermal energy storage verification test loop (TESET) under construction at KAERI. The hot leg piping with sodium coolant at 700 ℃ connects the main components of the loop heater, hot storage tank, and air-to-sodium heat exchanger. Currently, the design rules of ASME B31.1 and RCC-MRx provide design procedures for high-temperature piping in the creep range for Type 316L stainless steel. However, the design material properties around 700 ℃ are not available in those rules. Therefore, a number of material tests, including creep tests at various temperatures, were conducted to determine the insufficient material properties and relevant design coefficients so that high-temperature design on the 700 ℃ piping may be possible. It was shown that Type 316L stainless steel can be used in a 700 ℃ high-temperature piping system of Generation IV reactor systems or a renewable energy systems, such as thermal energy storage systems, for a limited operation time.

A method on integrity evaluation with high reliability for superheater structure in a supercritical thermal power plant (초임계압 화력 과열기 구조의 고신뢰도 건전성 평가 방법)

  • Lee, Hyeong-Yeon;Ju, Yong-Sun;Choi, Hyun-Sun;Won, Min-Gu;Huh, Nam-Su
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.65-73
    • /
    • 2020
  • Integrity evaluations on a platen superheater were conducted as per ASME Section VIII Division 2(hereafter 'ASME VIII(2)') which was originally used for design with implicit consideration of creep effects. A platen superheater subjected to severe loading conditions of high pressure and high temperature at creep regime in a supercritical thermal plant in Korea was chosen for present study. Additional evaluations were conducted as per nuclear-grade high-temperature design rule of RCC-MRx that takes creep effects into account explicitly. Comparisons of the two results from ASME VIII(2) and RCC-MRx were conducted to quantify the conservatism of ASME VIII(2). From present analyses, it was shown that the design evaluation results exceeded allowable limits of RCC-MRx for the plant design conditions although limits of ASME VIII(2) were satisfied regardless of operation time, which means that design as per ASME VIII(2) might be potentially non-conservative in case of operation in creep range. A high-temperature design evaluation program as per RCC-MRx, called 'HITEP_RCC-MRx' has been used and it was shown that pressure boundary components can be designed reliably with the program especially for the loading conditions of long-term creep conditions.

High-Temperature Design and Integrity Evaluation of Sodium-Cooled Fast Reactor Decay Heat Exchanger (소듐냉각고속로 붕괴열교환기의 고온 설계 및 건전성 평가)

  • Lee, Hyeong-Yeon;Eoh, Jae-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1251-1259
    • /
    • 2013
  • In this study, high temperature design and creep-fatigue damage evaluation of a decay heat exchanger (DHX) in the decay heat removal systems of a sodium-cooled fast reactor (SFR) have been performed. Detail design and 3D finite element analysis have been conducted for the DHXs to be installed in active and passive decay heat removal systems in Korean Generation IV SFR, and the DHX installed in the STELLA-1(Sodium integral effect test loop for safety simulation and assessment) at KAERI (Korea Atomic Energy Research Institute). Evaluations of creep-fatigue damage based on full 3D finite element analyses were conducted for the two Mod.9Cr-1Mo steel heat exchangers according to the elevated temperature design codes of ASME Section III Subsection NH and RCC-MR code. Code comparisons were made based on the creep-fatigue damage evaluation and issues on conservatisms of the design codes were discussed.

Development of Web-based Design Compatibility Assessment Program for High Temperature Reactor (고온로 설계 적합성평가 프로그램 개발)

  • Cho, Doo Ho;Surh, Han Bum;Choi, Jae Boong;Huh, Nam Su;Choi, Young Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 2013
  • In this paper, W-DCAP-HTR(Web-based Design Compatibility Assessment Program for High Temperature Reactor) which will be used to check the design criteria for high temperature reactor is newly proposed. To do this, the assessment procedure of the ASME Sec.III Div.5 such as time-dependent primary stress limit, accumulated inelastic strain, and creep-fatigue damage evaluation were investigated. Furthermore, the trend of candidate materials for high temperature reactor was also reviewed. Then, all assessment procedures for high temperature reactor have been computerized to enhance the efficiency and to reduce the possibility of human error during calculating procedure by hand calculation. It can be directly conducted by adopting the actual thermal and structural analysis results. The validation of W-DCAP-HTR has been demonstrated by benchmark analysis.

High Temperature Structural Integrity Evaluation Method and Application Studies by ASME-NH for the Next Generation Reactor Design

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2061-2078
    • /
    • 2006
  • The main purpose of this paper is to establish the high temperature structural integrity evaluating procedures for the next generation reactors, which are to be operated at over 500$^{\circ}C$ and for 60 years. To do this, comparison studies of the high temperature structural design codes and assessment procedures such as the ASME-NH (USA), RCC-MR (France), DDS (Japan), and R5 (UK) are carried out in view of the accumulated inelastic strain and the creep-fatigue damage evaluations. Also the application procedures of the ASME-NH rules with the actual thermal and structural analysis results are described in detail. To overcome the complexity and the engineering costs arising from a real application of the ASME-NH rules by hand, all the procedures established in this study such as the time-dependent primary stress limits, total accumulated creep ratcheting strain limits, and the creep-fatigue damage limits are computerized and implemented into the SIE ASME-NH program. Using this program, the selected high temperature structures subjected to two cycle types are evaluated and the parametric studies for the effects of the time step size, primary load, number of cycles, normal temperature for the creep damage evaluations and the effects of the load history on the creep ratcheting strain calculations are investigated.

Evaluation of mechanical and thermal properties of insulation materials for HTS power devices at liquid nitrogen temperature

  • Shin, Hyung-Seop;Diaz, Mark Angelo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.53-57
    • /
    • 2017
  • In superconducting power devices including power cables in which high temperature superconducting (HTS) tapes are utilized, a reliable electrical insulation should be achieved for its maximum performance. For an efficient design of HTS superconducting devices, a comparative evaluation of the mechanical and thermal propperties for various insulation materials at cryogenic temperatures is required. Especially, in the process of the property evaluation of the sheet-shaped insulation materials, anisotropy according to the machining direction should be considered because the mechanical and thermal properties are significantly influenced by the sample orientation. In this study, the cryogenic thermal and mechanical properties of various insulation material sheets such as PPLP, Cryoflex, Teflon, and Kapton were determined considering sample orientation. All samples tested at cryogenic temperature showed significantly higher tensile strength as compared with that of room temperature. The ultimate tensile strength at both temperature conditions significantly depended upon the sample orientation. The thermal properties of the insulation materials exhibited a slight difference among samples depending on the orientation: for the PPLP and Cryoflex, the CD orientation showed larger thermal contraction up to 77 K as compared to the MD one. MD samples in PPLP and Cryoflex showed a lower CTE and thermal contraction which made it more promising as an insulation material due to its comparable CTE with HTS CC tapes.

A Study on HIGH TEMPERATURE FRACTURE TOUGHNESS of Pressure Vessel Steel SA516 at High Temperature. (압력용기용강의 고온파괴인성에 관한 연구)

  • 박경동;김정호
    • Proceedings of the KWS Conference
    • /
    • 2001.05a
    • /
    • pp.228-231
    • /
    • 2001
  • Elastic-plastic fracture toughness $J_{1c}$ can be used as an effective design criterion in elastic plastic fracture mechanics. Most of these systems are operated at high temperature and $J_{1c}$ values are affected by temperature. therefore, the $J_{1c}$ valuse at high temperature must be determined for use of integrity evaluation and designing of such systems. Elastic-plastic fracture toughness $J_{1c}$ tests were performed on SA516 carbon steel plate and test results were analyzed according to ASTM E 813-8, ASTM 1813-89. Safety and integrity are required for reactor pressure vessels vecause pthey are operated in high temperature. there are single specimen method, which used as evaluation of safety and integrity for reactor pressure vessels. In this study, elastic-plastic fracture toughness$(J_{1c})$ and $J-\Delta{a}$ of SA 516/70 steel used as reactor pressure vessel steel are measured and evaluated at room Temperature, $150^{\circ}C$, $250^{\circ}C$ and $370^{\circ}C$ according to unloading compliance method.

  • PDF

Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell (고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가)

  • KIM, JI-HONG;KIM, MINJIN;KIM, JINSOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.