• Title/Summary/Keyword: High-strength mortar-filled sleeve bar splice

Search Result 5, Processing Time 0.02 seconds

Structural Performance of Mortar-filled Sleeve Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading (반복하중을 받는 SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음의 구조성능)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.180-192
    • /
    • 2008
  • The purpose of this research is to evaluate the structural performance of mortar-filled ductile cast iron sleeve splice developed for SD500 high-strength reinforcing bar under cyclic loading. The test variables adopted in this study are the development length of bar, compressive strength of mortar, bar size, sleeve types and others. In this research, it is showed that the mortar-filled sleeve splice for SD500 high-strength bar satisfied the structural performance required in ACI, AIJ code as well as domestic code. Also the results of experimental research presented in this paper provided basic engineering data for developing a reasonable design method of mortar-filled sleeve splice for SD500 high-strength reinforcing bar.

Evaluation on Stiffness of Mechanical Sleeve Bar Splice Filling High-strength Mortar Under Monotonic Loading (고강도 모르타르를 충전한 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성 평가)

  • Kim, Hyong Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.79-88
    • /
    • 2012
  • The purpose of this study is to evaluate the stiffness of the mechanical sleeve reinforcement splices filling high-strength mortar under monotonic loading. For this objective, we analyzed and compared the previous test data of 189 actual-sized mortar-filled sleeve bar splices specimens, including the reinforcing bar splices prepared and tested by the author. The paper results indicated that the minimum values of compressive strength of mortar($f_g$) multiplied by the ratio of reinforcement development length to bar diameter(L/d) were suggested for holding the stiffness of the mortar-filled sleeve reinforcement splices required in AIJ code.

A Study on the Development of Chonggu Splice-Sleeve System (청구 스플라이스 슬리브 시스템 개발에 관한 연구)

  • 곽철승;이용재;이동우;김병균;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.508-513
    • /
    • 1996
  • The purpose of this paper, having chosen the connection method, filled by High-strength mortar, in conncetion of PC member, is to study the mechanical behaviour and practical usage of the method. The paper estimates the connection ability of Reinforced-bar, that is, Sleeve considering the effect of Reinforced-bar's dimeter. Sleeve's length and diameter in the structural behaviour of mortar-filled connection, therefore the behaviour of Splice-Sleeve exists in concrete practically. This paper discusses the effect of the concrete in Splice-Sleeve. Also, to estimate structural behaviour in a practical wall panel, the upper and bottom wall panels are produced and the behaviour of Splice-Sleeve is discussed. And then Vertical Tie Bar being designed by using Precast method, this paper presents the various application and the practicable method using Splice-Sleeve.

  • PDF

Structural Performance of High Strength Grout-Pilled Splice Sleeve System (고강도 모르타르 충전식 철근이음의 구조성능에 관한 실험연구)

  • 김형기;안병익;남재현;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.516-524
    • /
    • 2001
  • Among many connection methods of reinforcing bar, the grout-filled splice sleeve system is very effective method of precast concrete construction due to its superior construction efficiency, such as large allowable limit to arrangement of reinforcing bars, good application of large sized reinforcing bars. In this study, totally 20 full-sited specimens were made and tested under monotonic and cyclic loading in order to extend the usage range of grout-filled splice sleeve system. The experimental variables adopted in this study are size of reinforcing bars embedded in upper and lower part of sleeve and compressive strength of filled mortar etc. After test was performed, the results were compared and analyzed with respect to previous test of author. Following main conclusions are obtained : 1) The structural performance of splice sleeve system is improved with increasing compressive strength of filled mortar. And also it was verified that the splice sleeve system with over 700 kgf/㎠ mortar compressive strength and over 6.54 development length of reinforcing bar retains the structural performance of over A class(AIJ Criteria). 2) In the case of using different size of reinforcing bars embedded in upper and lower part of sleeve, the result show that splice sleeve matching with large sized reinforcing bar must be used. And also up to 2 level smaller size of reinforcing bar compared to large reinforcing bar embedded in sleeve can be used.

Evaluation on Stiffness of High-strength Mortar-filled Sleeve Bar Splice Under Cyclic Loading (반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음에 대한 강성 평가)

  • Kim, Hyong Kee;Chung, Goo Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.85-93
    • /
    • 2013
  • In order to make a more reasonable evaluation on the stiffness of the high-strength mortar-filled sleeve bar splices under cyclic loading, we investigated and analyzed the existing experiment data of 106 full-sized reinforcing bar splices with test variables such as compressive strength of mortar, development length of reinforcement and sleeve type, etc. The following were found: 1) If mortar and the reinforcement development length with $f_{g^*}$(L/d) of more than 340 is used, the cast iron sleeve bar splices for SD350 and SD400 will have the stiffness of higher than A class of the AIJ code. 2) If mortar and the reinforcement development length with $f_{g^*}$(L/d) of more than 400 is used, the cast iron sleeve splices and pipe sleeve splices for SD500 will have the stiffness of higher than A class of the AIJ code.