• Title/Summary/Keyword: High-speed pulse

검색결과 466건 처리시간 0.028초

A New High Speed Addressing Method Using The Priming Effect in AC PDP

  • Kim, Jae-Sung;Yang, Jin-Ho;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.105-108
    • /
    • 2003
  • A new high speed addressing method is proposed to reduce the addressing time below lus per line in AC PDP. In this method, the priming discharge is used to achieve a high speed addressing without adding an auxiliary electrode. Two different types of priming discharges were studied to achieve a high speed addressing and also reduce the inherent light output caused by the priming discharge in order to improve the contrast ratio characteristics. In the panel experiment, the addressing was successfully done with a lus address pulse width in the new method and the better contrast ratio was achieved in the Y-A priming rather than the Y-X priming case even though the reduction of the address period was smaller than that of the Y-X priming due to the extra address time for the priming discharges.

  • PDF

Adaptive Techniques for Joint Optimization of XTC and DFE Loop Gain in High-Speed I/O

  • Oh, Taehyoun;Harjani, Ramesh
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.906-916
    • /
    • 2015
  • High-speed I/O channels require adaptive techniques to optimize the settings for filter tap weights at decision feedback equalization (DFE) read channels to compensate for channel inter-symbol interference (ISI) and crosstalk from multiple adjacent channels. Both ISI and crosstalk tend to vary with channel length, process, and temperature variations. Individually optimizing parameters such as those just mentioned leads to suboptimal solutions. We propose a joint optimization technique for crosstalk cancellation (XTC) at DFE to compensate for both ISI and XTC in high-speed I/O channels. The technique is used to compensate for between 15.7 dB and 19.7 dB of channel loss combined with a variety of crosstalk strengths from $60mV_{p-p}$ to $180mV_{p-p}$ adaptively, where the transmit non-return-to-zero signal amplitude is a constant $500mV_{p-p}$.

전기유압식 서보인덱싱 시스템의 PWM 제어에 관한 연구 (A Study on PWM Control of an Electro-Hydraulic Servo Indexing System)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.236-243
    • /
    • 1999
  • This study deals with the application of high speed on-off valves to an electro-hydraulic servo indexing system incorporated electro-hydraulic servo valces. Comparing with the electro-hydraulic servo valve the high speed on-off valve has some merits. Which included low price robustness to the oil contamination and dircect control without D/A converter. The considered sys-tem of this study is controlled by pulse width modulation(PWM) of the control law which is pro-duced by a PID controller which is used broadly in industrial equipments. The dynamic character-istics corresponding to variations of system parameters such as inertia moment system gain and supply pressure are investigated by computer simulation and experiment. Consequently the availability of the application of high speed on-off valve to servo indexing system instead of electro-hydraulic servo valve is confirmed.

  • PDF

PWM 방식 고속 전자석에 관한 연구 (A study on the PWM type High Speed Electromagnet)

  • 송창섭;양해정;송성배
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.127-135
    • /
    • 1994
  • This paper is concerned about a high speed electromagnet of Pressure control solenoid valve. Solenoid valve is controlled by means of Pulse width modulation. The magnetostatic field problem on a solenoid is numerically solved by the 2-D axisymmetric finite element method. And permeance method is adopted for analysing the static and dynamic property of solenoid part theoretically. In addition, in this study, experiments on solenoid part were performed in order to measure the magnetic force and plunger displacement. The numerical results coincided with the experimental results. As a result, the magnetic force has the linear relation with displacement of plunger and the primary factors on the performance of PWM type high speed electromagnet are coil resistance, plunger mass, and the length of air gap between plunger and core.

  • PDF

Optimal PAM Control for a Buck Boost DC-DC Converter with a Wide-Speed-Range of Operation for a PMSM

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Senjyu, Tomonobu;Yona, Atsushi;Saber, Ahmed Yousuf
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.477-484
    • /
    • 2010
  • A pulse width modulation-voltage source inverter (PWM-VSI) is used for variable speed permanent magnet synchronous motor (PMSM) drives. The PWM-VSI fed PMSM has two major disadvantages. Firstly, the PWM-VSI DC-link voltage limits the magnitude of the PMSM terminal voltage. As a result, the motor speed is restricted. Secondly, in a low speed range, the PWM-VSI modulation index declines. This is caused by a high DC-link voltage and a low terminal voltage ratio. As a result, the distortion of the voltage command and the stator current are increased. This paper proposes an optimal pulse amplitude modulation (PAM) control which can adjust the inverter DC-link voltage by using a buck-boost DC-DC converter. At a low speed range, the proposed system can reduce the distortion of the voltage command, which improves the stator current waveform. Also, the allowable speed range is extended. In order to verify the proposed method, experimental results are provided to confirm the simulation results.

BLDC 서보 모터의 관측자를 이용한 강인 제어 (Robust Control using Observer for Brushless DC Servo Motor)

  • 신두진;허욱열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권8호
    • /
    • pp.451-458
    • /
    • 2000
  • The precise speed and position control technique for Brushless DC Motor demands accurate position and speed feedback information. Generally, resolver or absolute encoders are used as speed and positiion sensor. But they increase cost and more problem happens at low speed than high speed specially. Therefore, in this paper, optimal speed observer is proposed for decreasing size and cost of whole system. And also, we consider the error problem about the system modeling and measurement at low speed range as well as high speed. The overall system consists of two parts, a drive and a speed observer. We make use of Least square curve fitting algorithm as speed observer and can overcome low resolution by proposed observer. Also, because of using the signal of hall sensor, robust control is possible in low speed as well as high speed for the change of the parameters of the system and disturbance. To construct observer using the signal of hall sensor, we design the pulse multiplier circuit and the software of microprocessor, AT89CC2051. Finally, the performance of the proposed observer is exemplified by some simulations and experiments.

  • PDF

유압실린더의 학습에 의한 위치제어 (Piston control of hydraulic cylinder using an learing strategy)

  • 박성환;권기수;허준영;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1122-1126
    • /
    • 1991
  • As microcomputers have become widespread and the high speed solenoid valves have been developed, digitally controlled hydraulic systems are used in many applications. This study deals with position control of hydraulic cylinder operated by two port 3-way high speed solenoid valve using a self-learning strategy. This was done by developing a control algorithm for the microcomputer which always automatically adjust the length of control pulse to the optimum value in accordance with the error regardless of changes in the operating condition and physical differences between components. Tests carried out in the laboratory indicate that a positional accuracy could be improved.

  • PDF

고속 신호처리 회로에 의한 고속철도 차륜검사 (Improvement of Signal Processing Circuit for Inspecting Cracks on the Express Train Wheel)

  • 황지성;이진이;권석진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.579-584
    • /
    • 2008
  • 고속철도 차륜의 미소결함을 고속 고공간 분해 능으로 측정할 수 있는 새로운 비파괴검사법이 요구되고 있다. 본 연구는 종래의 스캔형 자기카메라를 개선하여, 다중증폭회로와 결함표시를 위한 펄스 발생기를 장착한 신호처리회로를 제안한다. 홀센서를 선형으로 배열하고, 배열의 직각방향으로 차륜이 정속으로 회전하게 하면, 차륜의 답면을 검사할 수 있다. 각각의 홀전압을 증폭하고, AD변환기를 통하여 $\mu$-processor에 의하여 시간에 따른 전압차, 즉 ${\partial}V_H/{\partial}t$를 연산한다. ${\partial}V_H/{\partial}t$가 결함의 존재를 의미하는 비교치보다 클 때 pulse 신호가 발생하여 결함을 지시한다. 휠 시험편을 이용하여 제안된 방법을 검증하였다.

  • PDF

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.