• 제목/요약/키워드: High-rise apartment building

검색결과 183건 처리시간 0.022초

SD500철근 커플러 이음의 편익/비용분석에 관한 연구 (A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement)

  • 김재엽;권여울;김준영
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정 (Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가 (Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings)

  • 전성하;신동현;박지훈
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.293-303
    • /
    • 2020
  • Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.

판상형 공동주택의 동 배치 및 종횡비에 따른 풍압계수 특성에 관한 연구 (A Study on the Wind Pressure Coefficients of Flat-type Apartment Complexes Considering Building Layout and Aspect Ratio)

  • 윤성훈
    • 한국융합학회논문지
    • /
    • 제12권9호
    • /
    • pp.153-159
    • /
    • 2021
  • 건축물의 환기성능 평가를 위한 모델링 과정에서 핵심 경계조건으로 활용되는 풍압계수는 통상 저층형 단일 건물에 대해서만 자료화되어 있어, 공동주택 단지와 같은 고층형 집합주택의 모델링 시에는 적용할 수 없다. 이에 본 연구에서는 CFD(Computational Fluid Dynamics)해석을 통해 건물의 배치 및 종횡비가 다른 판상형 공동주택에 대하여 풍향각에 따른 풍압계수의 특성을 분석하고 유형화함으로써 환기 모델링 시 참고할 수 있는 기초자료를 제시하였다. 풍향각 0도의 경우 가장 풍상측에 위치한 건물의 정면에서는 좌우가 반전된 S자 형태의 풍압계수 분포가 나타났으며, 최하층, 최상층 및 2개의 변곡점에 해당하는 풍압계수는 건물의 높이와 관계없이 비교적 근사한 값을 보였다. 저층부의 변곡점은 약 11m 높이에 형성되었으며, 고층부 변곡점의 높이는 건물의 높이에 비례하는 추세식을 통해 산출가능함을 확인하였다. 또한 풍향각 45도 조건을 제외하면 대부분의 조건에서 풍압계수의 평균값을 적용 가능함을 확인하였다.

고층건물 기둥의 부등축소량 예측 및 시공오차 보정에 관한 연구 (Prediction and Compensation of Differential Column Shortening in High-Rise Building Structures)

  • 조창휘;송진규;이현호;조석희
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.258-266
    • /
    • 1996
  • The purpose of this study is to make a reasonable correction in construction stage through exact prediction of long-time differential column shortening that occurs in the high-rise RC building. For this, a self-developed program adopted PCA code is used to predict differential column shortening with sequential loading process. Using this program, the amount of the different column shortening of Amatapura Apartment in Indonesia is predicted and the effect is analyzed. From the result, the major factor affecting the shortening amount in columns is elastic strain and the effect of shrinkage is very small rather than creep. And maximun differential column shortening is appeared near the middle of the building.

  • PDF

여름철 Apt현장 조건에서의 철근 및 거푸집의 온도특성 (Temperature characteristics of iron and molds in summer apartment conditions)

  • 이제현;문병룡;이상운;이정교;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2016
  • On apartment construction sites in hot weather environments, the high temperature of 30℃ and above and radiation from the sun cause iron and mold temperatures to rise, which lowers worker efficiency and has a negative effect on the deposited concrete. Therefore this study measured the temperature of D10 ~ D16 iron and aluminum items actually used on box frame apartment construction sites currently under construction, in order to give reference information to solve hot weather concrete problems. The temperature measurement results showed that for iron, temperatures rose to around 45℃, and for mold around 58.8℃, calling for safety measures for workers in case of possible burning and other problems.

  • PDF

3차원 GIS 모델을 활용한 공동 주택 단지의 일조율과 천공율의 상관관계에 관한 연구 - 중계동 아파트 62개 단지를 대상으로 - (Study on the Relationship between the Possible Duration of Sunshine & the Possible Amount of Visible Sky in Large-Scale Apartment Sites Using the 3D GIS Models - Focused on 62 Apartment Sites in Junggye-dong -)

  • 조용성;원제무
    • 한국주거학회논문집
    • /
    • 제22권1호
    • /
    • pp.105-114
    • /
    • 2011
  • There are various kinds of Large-Scale apartment sites in Seoul. There are more households in apartment sites than single family houses. Nowadays, it is easy to find a lot of apartment sites built in the style of a high rise building. On the matter of space, a building is influenced by the buildings near it. The influence a building has to another is different in both qualitative and quantitative ways. Therefore, in the case of apartment sites, the environmental surroundings of each household is affected by the nearby buildings. For these reasons, the environment is having more and more influence on the price of each household in apartment sites. This paper has defined Sunshine and Sky as the major environmental elements. In order to be analyzed, they have to be measurable. Thus, there are two types of variables in environmental surrounding of apartment sites, -the Duration of Sunshine and the possible amount of visible Sky- the significant variables which influence the housing price. This paper deals with the relationship between the possible duration of sunshine and the possible amount of sky a household is visible to. It focused on 62 different apartment sites which were built after 1990. It is based on the 3-dimensional Geographic Information System & Computer Aided Engineering for analyzing the sunshine simulation and the viewing simulation. This paper will be helpful for designing the apartment sites considering the balance between sunshine and sky.

시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구 (Space study on Lighting Performance For Residential Buildings By using Simulation Analysis)

  • 임태섭;임정희;김병선
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

공동주택 슬래브 두께변화에 따른 공사비 증가 산정 평가 - 바닥충격음 법제화 시행에 따른 표준바닥구조를 중심으로 - (An Evaluation on a calculation the increased cost of construction according to the Depth change of Concrete Slabs in Apartment Building by executing the law of floor impact sound)

  • 이원열;정상민;신덕
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.161-166
    • /
    • 2005
  • This study is to evaluate on the increased cost of construction according to the depth change of concrete slabs in apartment building. When we increased the depth of concrete slab from 150mm to 180, 210mm, the qualitative and cost of construction were calculated by the high-rise type, the unit-size type. As a result of this study, in 32 Pyong type, increment of construction cost rate appeared by $5.1\%$ in case of increase from slab 150mm to 180mm, and $10.0\%$ in case of increase from slab 150mm to 210mm. In 45 Pyong type, Increment of construction cost rate appeared by $5.7\%$ in case of increase from slab 150mm to 180mm, and $10.2\%$ in case of increase from slab 150mm to 210mm. In 55 Pyong type, Increment of construction cost rate appeared by $2.4\%$ in case of increase from slab 150mm to 180mm, and $8.9\%$ in case of increase from slab 150mm to 210mm.