• Title/Summary/Keyword: High-rise Structures

검색결과 751건 처리시간 0.026초

Experimental studies into a new type of hybrid outrigger system with metal dampers

  • Wang, A.J.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.183-194
    • /
    • 2017
  • This paper presents the experimental investigation into a new type of steel-concrete hybrid outrigger system developed for the high-rise building structure. The steel truss is embedded into the reinforced concrete outrigger wall, and both the steel truss and concrete outrigger wall work compositely to enhance the overall structural performance of the tower structures under extreme loads. Meanwhile, metal dampers of low-yield steel material were also adopted as a 'fuse' device between the hybrid outrigger and the column. The damper is engineered to be 'scarified' and yielded first under moderate to severe earthquakes in order to protect the structural integrity of important structural components of the hybrid outrigger system. As such, not brittle failure is likely to happen due to the severe cracking in the concrete outrigger wall. A comprehensive experimental research program was conducted into the structural performance of this new type of hybrid outrigger system. Studies on both the key component and overall system tests were conducted, which reveal the detailed structural response under various levels of applied static and cyclic loads. It was demonstrated that both the steel bracing and concrete outrigger wall are able to work compositely with the low-yield steel damper and exhibits both good load carrying capacities and energy dispersing performance through the test program. It has the potential to be applied and enhance the overall structural performance of the high-rise structures over 300 m under extreme levels of loads.

Advances in the design of high-rise structures by the wind tunnel procedure: Conceptual framework

  • Simiu, Emil;Yeo, DongHun
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.489-503
    • /
    • 2015
  • This paper surveys and complements contributions by the National Institute of Standards and Technology to techniques ensuring that the wind tunnel procedure for the design of high-rise structures is based on sound methods and allows unambiguous inter-laboratory comparisons. Developments that enabled substantial advances in these techniques include: Instrumentation for simultaneously measuring pressures at multiple taps; time-domain analysis methods for estimating directional dynamic effects; creation of large simulated extreme directional wind speed data sets; non-parametric methods for estimating mean recurrence intervals (MRIs) of Demand-to-Capacity Indexes (DCIs); and member sizing based on peak DCIs with specified MRIs. To implement these advances changes are needed in the traditional division of tasks between wind and structural engineers. Wind engineers should provide large sets of directional wind speeds, pressure coefficient time series, and estimates of uncertainties in wind speeds and pressure coefficients. Structural engineers should perform the dynamic analyses, estimates of MRIs of wind effects, sensitivity studies, and iterative sizing of structural members. The procedure is transparent, eliminates guesswork inherent in frequency domain methods and due to the lack of pressure measurements, and enables structural engineers to be in full control of the structural design for wind.

Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance

  • Kumano, Takehito;Yoshida, Satoshi;Saburi, Kazuhiro
    • 국제초고층학회논문집
    • /
    • 제6권3호
    • /
    • pp.217-226
    • /
    • 2017
  • This paper summarizes the structural concept and design of the "Nakanoshima Festival Tower West" in Osaka, Japan, which is 200m high and has a super-high damping system. Its superstructure is mainly composed of a central core and outer tube frames. It has a bottom truss structure at the boundary between the low-rise and mid-rise sections of the building, where the column arrangement is changed. Besides, the high-rise section of the building has a neck truss structure. These truss structures smoothly transfer the axial forces of the columns and reduce the flexural deformations induced by horizontal loads. Oil dampers with extremely high damping capacity are installed in the rigid walls named the "Big Wall Frames" of the low-rise section. Moreover, many braces and damping devices are well arranged in the center core of each story. The damping effects of these devices ensure that all structural members are remain within the elastic range and that story drifts are within 1/150 in large earthquakes. This super-high damping structure in the low-rise section is named the "Damping Layer". The whole structural system is named the "Super Damping Structure". The whole structural systems enhance the building's safety, comfort and Business Continuity Planning (BCP) under large earthquakes.

돔형 스페이스 프레임 구조물의 하중모드에 따른 분기점 특성에 관한 연구 (A Study on the Critical Point and Bifurcation According to Load Mode of Dome-Typed Space Frame Structures)

  • 손수덕;김승덕;이승재;김종식
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.121-130
    • /
    • 2011
  • 스페이스 프레임 구조물은 연속체 쉘 구조물의 원리를 이용하여 매우 넓은 공간을 효과적 으로 덮을 수 있는 구조물이지만 뜀좌굴 및 분기좌굴 등과 같은 불안정거동은 돔형 구조물에서는 더욱 복잡하게 나타난다. 또한 붕괴메커니즘의 이론적 연구와 실험적 연구결과들 사이에서도 많은 차이를 보인다. 본 논문에서는 미적 효과가 크며 단층의 대공간을 확보하기에 적합한 돔형 공간 구조물의 구조 불안정 특성을 접선강성방정식을 이용하여 비선형 증분해석을 수행하고, Rise-span(${\mu}$)비 및 하중모드($R_L$)에 따른 임계점과 분기점의 특성을 돔형 공간구조물의 예제를 통해 고찰하였다. 여기서 불안정점은 증분해석과정을 통해서 예측할 수 있었으며, 예제에서 낮은 ${\mu}$에서는 전체좌굴이, 높은 ${\mu}$의 경우는 절점좌굴이 지배적이며, 낮은 $R_L$에서 정점좌굴이, 높은 $R_L$에서는 전체좌굴이 지배적이고, 전체좌굴이 나타나는 경우, 분기좌굴하중은 완전형상의 극한점좌굴하중의 약 50%에서 70%의 분포를 보였다.

A State-of-art of Experimental Research and Calculated Models of Dowel-type Timber Connections in Fire

  • Luo, Jing;He, Minjuan;Li, Zheng
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.285-297
    • /
    • 2021
  • Fire safety is one of the most significant issues for the design of mid-rise and high-rise timber structures. A large number of experimental tests were conducted during the last three decades to investigate the fire performance of the dowel-type timber connections. Many influenced parameters (e.g. the thickness of the side timber, the load ratio, the fasteners type etc.) were considered in those experiments. Relevant calculated models were proposed by previous researchers to estimate the fire resistance of the connections. In this study, a series of experimental programs of dowel-type connections in fire are collected. Then, empirical formulas proposed by EN 1995-1-2, Fire safety in timber buildings, and previous researchers are presented and analyzed. The accuracy of those formulas is checked by comparisons between the experimental data and estimated results. The collected experimental research and empirical formulas can be used as the reference for the fire design of dowel-type timber connections in the future.

국내외 초고층 건축물의 대단면 매트기초 시공사례와 분석 (Case Study on Mega Foundations of Domestic and Foreign Super High-Rise Buildings)

  • 박영석;이해출;김경민;조창식;임홍철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.17-19
    • /
    • 2010
  • This paper describes the possibility of the raft thickness reduction for mega foundations system of super high-rise buildings through a case study on domestic and foreign super high-rise buildings. In case of super high-rise buildings, the size of foundations, especially raft becomes wider and deeper because of heavy upper load. It is difficult to pour concrete of this kind of mega foundation, and cracks by hydration heat could happen. Therefore, there are several ways to reduce the raft thickness of mega foundations. Piled-raft could be the one because moment and shear load that the raft subjects on by soil reaction are lower. The effect of the piled-raft foundation on the raft thickness reduction could be confirmed by comparison of super high-rise buildings with pile, piled-raft and mat foundation. Furthermore, it was showed that the raft thickness could be more reduced by locating piles right under the vertical members of super structures.

  • PDF

우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구 (A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design)

  • 이강훈
    • 한국화재소방학회논문지
    • /
    • 제4권2호
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

Optimal intensity measures for probabilistic seismic demand models of RC high-rise buildings

  • Pejovic, Jelena R.;Serdar, Nina N.;Pejovic, Radenko R.
    • Earthquakes and Structures
    • /
    • 제13권3호
    • /
    • pp.221-230
    • /
    • 2017
  • One of the important phases of probabilistic performance-based methodology is establishing appropriate probabilistic seismic demand models (PSDMs). These demand models relate ground motion intensity measures (IMs) to demand measures (DMs). The objective of this paper is selection of the optimal IMs in probabilistic seismic demand analysis (PSDA) of the RC high-rise buildings. In selection process features such as: efficiency, practically, proficiency and sufficiency are considered. RC high-rise buildings with core wall structural system are selected as a case study building class with the three characteristic heights: 20-storey, 30-storey and 40-storey. In order to determine the most optimal IMs, 720 nonlinear time-history analyses are conducted for 60 ground motion records with a wide range of magnitudes and distances to source, and for various soil types, thus taking into account uncertainties during ground motion selection. The non-linear 3D models of the case study buildings are constructed. A detailed regression analysis and statistical processing of results are performed and appropriate PSDMs for the RC high-rise building are derived. Analyzing a large number of results it are adopted conclusions on the optimality of individual ground motion IMs for the RC high-rise building.