• 제목/요약/키워드: High-power transformer

검색결과 1,043건 처리시간 0.031초

300 W급 평면 변압기의 설계 및 분석 (Design and Analysis of the 300 W Planar Transformer)

  • 이해연;김현식;김종령;오영우;김은수
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.502-507
    • /
    • 2004
  • The forward planar transformer, which had power capacity of 300 W, input voltage of 220 V, output voltage of 15 V, and switching frequency of 300 KHz, was designed and manufactured by using the planar core with large effective area and the flat copper leadframes for miniaturization and high efficiency of the switching mode power supply (SMPS). As well as, a forward converter equipped with the above mentioned planar transformer was manufactured and electromagnetic characteristics were investigated. The numerical value of turns for 1st and 2nd winding were 15 and 2 respectively The self inductance of 1st winding was 1.592 mH, very low leakage inductance of 2.7 $\mu$H, and the coupling factor of 0.928 were obtained at switching frequency of 300 KHz. The high efficiency of 88.62 % for the SMPS equipped with planar transformer was obtained at power capacity of 300 W.

산업용 선형가속기 시스템 적용을 위한 30-MW 클라이스트론용 고 평균전력 펄스 트랜스포머의 설계 (Design of High Average Power Pulse Transformer for 30-MW Klystron of L-Band Linac Application)

  • 장성덕;손윤규;권세진;오종석;;;문성익;김상호;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1550-1551
    • /
    • 2006
  • An L-band linear accelerator system for e-beam sterilization is under design for bio-technology application. The klystron-modulator system as RF microwave source has an important role as major components to offer the system reliability for long time steady state operation. A PFN line type pulse generator with a peak power of 71.5-MW, $7{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present a system overview and initial design results of the high power pulse transformer.

  • PDF

L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가 (Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron)

  • 장성덕;손윤규;권세진;오종석;김상훈;양해룡;문성익;권봉환;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구 (A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer)

  • 변재영;김윤호
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.504-511
    • /
    • 2003
  • 본 연구에서는 네온 변압기를 세라믹 계열의 압전 변압기를 이용한 인버터식 네온관용 변압기를 제안하였다 인버터식 네온관용 압전 변압기의 주요 구성은 정류부, 발진부, 공진형 하프브릿지 인버터회로부 및 압전 변압기부로 구성 제작하였다. 네온관용 변압기는 지금까지 개발된 압전 변압기 용량 보다 대부분 큰 용량을 필요로 하고 있기 때문에 압전 변압기의 용량 증가를 위해 병렬 구동하였다 이때 병렬로 연결된 단층형 압전 변압기간 내부 임피던스 값의 불일치로 발생하는 불평형 전류를 최소화 하기 위하여 압전 변압기별로 LC 필터값을 분석 부착하여 전압의 왜곡율을 최소화 하여 안정된 정현파 출력을 구현하였다. 그리고 이를 컴퓨터 시뮬레이션 실험과 실제 네온관 부착 실험을 통하여 전력 밀도와 절연 레벨이 높고, 누설 자속이 없는 소형, 경량화된, 압전 변압기를 적용한 인버터식 네온관용 변압기가 기존의 자기식 네온관용 변압기 보다 우수함을 비교 입증하였다.

고효율 및 고역률 LED 구동회로 위한 Balanced Forward-Flyback 컨버터 (Balanced Forward-Flyback Converter for High Efficiency and High Power Factor LED Driver)

  • 황민하;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.492-500
    • /
    • 2013
  • A balanced forward-flyback converter for high efficiency and high power factor using a foward and flyback converter topologies is proposed in this paper. The conventional AC/DC flyback converter can achieve a good power factor but it has the high offset current through the transformer magnetizing inductor, which results in a large core loss and low power conversion efficiency. And, the conventional forward converter can achieve the good power conversion efficiency with the aid of the low core loss but the input current dead zone near zero cross AC input voltage deteriorates the power factor. On the other hand, since the proposed converter can operate as the forward and flyback converters during switch turn-on and turn-off periods, respectively, it cannot only perform the power transfer during an entire switching period but also achieve the high power factor due to the flyback operation. Moreover, since the current balanced capacitor can minimize the offset current through the transformer magnetizing inductor regardless of the AC input voltage, the core loss and volume of the transformer can be minimized. Therefore, the proposed converter features a high efficiency and high power factor. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터 (An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer)

  • 공영수;김은수;이현관
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.

HVC 내장형 고주파변압기를 이용한 Microwave Oven용 펄스전원장치에 관한 연구 (A Study on Pulse Power Suppuy for Microwave Oven Using HVC Embedded High Frequency Transformer)

  • 박강희;조준석;정병환;목형수;박현빈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.584-588
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage Capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, A new pulse power supply for Microwave Oven using novel HVC embedded high frequency transformer is proposed for down-sizing, cost reduction, and efficiency emprovement of Inverter type power supply. Also, equivalent circuit model is derived by impedance measurements. And the operation of proposed pulse power supply is verified by simulations and experimental results.

  • PDF

Conceptual Design of an HTS large power transformer with continuously transposed coated conductors

  • Lee, Se-Yeon;Park, Sang-Ho;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Il-Han;Chol, Kyeong-Dal;Hahn, Song-Yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.5-8
    • /
    • 2011
  • This paper shows results of a design work of a program that is to develop a large power single phase high temperature superconducting (HTS) transformer. The program forms a part of a national project in Korea. A target of the design work is an HTS power transformer with rated voltages of 154 kV/22.9 kV and material for windings is supposed to be coated conductor. The design results presents in this paper will include: 1)HTS winding structures for high voltage in liquid nitrogen, 2)design result of continuously transposed coated conductor (CTCC), 3)conceptual design of high voltage bushings, 4)cooling system. A feasibility study will succeed to this design work for construction of a prototype HTS power transformer with capacity/voltage of 33 MVA/154 kV.

고주파 트랜스포머의 권선기법 따른 손실특성 (Power Loss Characteristics according to Winding Method of High Frequency Transformer)

  • 김일남;윤신용;이공희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF

전력용변압기에서 UHF 부분방전 신호의 전파 특성 (Propagation Characteristics of Ultra High Frequency Partial Discharge Signals in Power Transformer)

  • 윤진열;한기선;주형준;구선근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.798-803
    • /
    • 2010
  • This paper describes the characteristics of electromagnetic wave propagation in power transformer. A transformer which is similar to 154 kV single phase on-site transformer unit was provided for the purpose of the experiment. The 12 dielectric windows on the transformer enclosure to install UHF (ultra high frequency) sensors and the full scale mock ups of winding and the core were also equipped in the transformer. Every sensors to be installed to the transformer was tested and verified whether they show same characteristics or not before the experiment. A discharge gap which was used as a PD (partial discharge) source moved to several necessary locations in the transformer to simulate dielectric defects. Propagation times of electromagnetic wave signal from PD source to sensors decided by the routes of both reflection phenomenon and diffraction phenomenon were compared each other. The experimental results showed propagation route of the PD signal makes an effect on the frequency spectrum of front part of the signal and the magnitude of the signal and propagation time of the signal when the signal is captured on the sensor.