• 제목/요약/키워드: High-performance liquid chromatography/Photodiode Array

검색결과 69건 처리시간 0.026초

Simultaneous Determination of Cinnamaldehyde and Coumarin in Oryeong-san using HPLC with Photodiode Array Detector

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • 대한한의학방제학회지
    • /
    • 제18권2호
    • /
    • pp.251-257
    • /
    • 2010
  • Objectives : To develop and validate High-performance liquid chromatography-photodiode array methods for simultaneous determination of two constituents in Oryeong-san(ORS). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 280 nm, were used for quantification of the two marker components of ORS. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was $H_2O$ and solvent B was acetonitrile. Results : Calibration curves were acquired with correlation coefficient ($r^2$)>0.9999, and the relative standard deviation(RSD) values(%) for intra- and inter-day precision were not exceed 1.0%. The recovery rate of each compound was in the range of 93.01-104.16%, with an RSD less than 2.0%. The contents of two compounds in ORS were 1.10-3.72 mg/g. Conclusions : The established HPLC method will be helpful to improve quality control of ORS.

Development of an analytical method for the quantification of oleanonic acid from mastic gum using HPLC/PDA

  • Hak-Dong Lee;Chang-Dae Lee;So Yeon Choi;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • 제66권
    • /
    • pp.67-72
    • /
    • 2023
  • A simple and accurate method was developed for the quantitative analysis of oleanonic acid (OA) from mastic gum. The analysis was carried out using reverse-phase high-performance liquid chromatography combined with a photodiode array detector (HPLC/PDA). Our optimized method was validated by measuring various parameters, using an INNO C18 column fitted with a gradient elution system. The results revealed limits of detection and quantification of 0.34 and 1.042 ㎍/mL, respectively. The OA calibration curve exhibited excellent linearity over the concentration range of 0.0625 to 2.0 mg/mL, with r2 =0.9996. Accuracy tests revealed a high recovery rate of 99.44-103.66%, with precision values below 0.15%. These results suggest that the present analytical method can identify and quantify OA in mastic gum with high precision. The HPLC approach developed in this study might be applied to routine analyses and large-scale extraction procedures for OA content quantification.

Quantitative analysis of massonianoside B in Pinus species using HPLC/PDA

  • Gia Han Tran;Jungwon Choi;Hee Jeong Min;Ja Jung Ku;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • 제66권
    • /
    • pp.153-158
    • /
    • 2023
  • Pinus species are native to the Northern Hemisphere and some parts of the tropics to temperate regions in the Southern Hemisphere. They were used as food and medicine in prehistoric times. Massonianoside B is a compound found in pine trees and possesses antioxidant activity. In order to determine the presence and content of this compound in Pinus species, three different parts (needles, branches, and bark) of three Pinus species were extracted and investigated. High-performance liquid chromatography with a gradient elution system along with a reverse-phase INNO column with photodiode array detector was employed. Results showed that the branches of the three Pinus species had higher massonianoside B content (5.502 to 9.751 mg/g DW) than either the needles or bark. Furthermore, among the three species, P. rigida × P. taeda had the highest concentration of total massonianoside B (11.557 mg/g DW). These findings thus provide evidence of biological activity in Pinus species and establish a foundation for further research.

Simultaneous Determination of Vitamin A and E in Infant Formula by HPLC with Photodiode Array Detection

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeong, Seung-Hwan;Shim, Sung-Lye;Kim, Kyong-Su;Yoon, Tae-Hyung;Leem, Dong-Gil;Jeong, Ja-Young
    • 한국축산식품학회지
    • /
    • 제31권2호
    • /
    • pp.191-199
    • /
    • 2011
  • The objective of this study was to develop a method to simultaneously quantify vitamins A and E in infant formula. To determine the vitamin A and E content, vitamin A and four different vitamin E isomers (${\alpha}$-, ${\beta}$-, ${\gamma}$-, and ${\delta}$-tocopherol) were separated by high performance liquid chromatography with a photodiode array detector using a Develosil RPAQUEOUS RP-$C_{30}$ column ($4.6{\times}250$ mm, 5 ${\mu}M$). The vitamin A and E contents in the certified reference material determined using this method were within the certified range of standard values. The limits of detection (LODs) and limits of quantitation (LOQs) for vitamin A were 0.02 and 0.06 ${\mu}g/L$, respectively. LODs and LOQs for the vitamin E isomers ranged from 0.20 to 0.55 and from 0.67 to 1.81 ${\mu}g/L$, respectively. Linear analyses indicated that the square of the correlation coefficient for the vitamin A and E isomers was 0.9997-0.9999. The recovery of vitamins ranged from 96.69 to 97.79%. The results demonstrate that this novel method could be used to reliably analyze vitamin A and E content in infant formula.

Determination of dextromethorphan and its metabolite dextrorphan in human urine by High-performance liquid chromatography

  • Son, Haeng-Ja;Park, Mee-Jung;Choi, Sang-Kil;Lim, Mi-Ae;Chung, Hee-Sun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.279.2-280
    • /
    • 2003
  • A simple and accurate reverse-phase high performance liquid chromatography (HPLC) coupled with photodiode array was developed for the determination of dextromethorphan(DM) and its metabolite dextrorphan(DX) in human urine. Chromatographic separation was accomplished on a cyano analytical column at 220 nm using a mobile phase containing 25 mM triethylammonium phosphate buffer(PH 3.0) in a 0-70% ACN gradient and triazolam(TZ) was used as internal standard(I.S). (omitted)

  • PDF

Quantitative and Qualitative Analysis of Alkaloids in Coptis chinensis (Coptidis Rhizoma) by LC-DAD and LC-ESI/MS

  • Yu, Young-Beob;Bae, Chang-Hyu
    • 한국자원식물학회지
    • /
    • 제30권6호
    • /
    • pp.693-698
    • /
    • 2017
  • The quality control of natural products is principal key to guarantee the Good Manufacturing Practices (GMP) and Good Clinical Practices (GCP) for the functional food, pharmaceuticals and cosmeceuticals in the industry. In this study, we examined the quantitative analysis of berberine as marker substance of Coptidis Rhizoma by high performance liquid chromatography-photodiode array detector (HPLC-DAD). The HPLC method was validated and met all the requirements for the quality control analysis recommended by FDA and ICH. The berberine was separated on a Xterra $C_{18}$ column ($5{\mu}m$, $4.6{\times}250mm$) using mobile phase consisting of distilled water and acetonitrile with $KH_2PO_4$ (3.4 g) and $Na_2SO_4$ (1.7 g). Calibration curve of berberine has been estimated (y = 42293.47x-41589 with the correlation coefficient 0.9999). The amount of berberine was calculated as 4.25%. And berberastine, palmatine, columbamine, jatrorrhizine, epiberberine, berberine and coptisine in the Coptidis Rhizoma were identified by high performance liquid chromatography - electrospray ionization-mass spectrometer (HPLC-ESI-MS) method.

Quality Evaluation of Modified Bo-Yang-Hwan-O-Tang by Capillary Electrophoresis and High-performance Liquid Chromatography

  • Chen, Jianbo;Wu, Enqi;Zhu, Hongmei;Lee, Kwan-Jun;Chu, Van Men;Cho, Cheong-Weon;Kim, Young-Ho;Park, Yong-Ki;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2666-2670
    • /
    • 2011
  • High-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify five active components in the modified herbal decoction Bo-Yang-Hwan-O-Tang (mBHT), i.e., amygdalin, decursin, paeoniflorin, salvianolic acid B, and calycosin-7-O-${\beta}$-D-glycoside. These components were identified by comparing their retention times and mass spectra with those of reference compounds. The conditions of both analytical methods were optimized and validated. Sufficient separation of target analytes was achieved using a buffer consisting of 40 mM sodium borate and 60 mM sodium dodecylsulfate (SDS) containing 10% methanol (pH 9.5) at 250 nm for CE analysis and gradient elution with a water-methanol mobile phase and ultraviolet (UV) photodiode array detector (DAD) at 250 nm for HPLC analysis. The mBHT components were determined within 65 min by HPLC and 16 min by CE. All calibration curves showed high linearity (R > 0.999) within the ranges tested. Intra-day and inter-day precision were less than 1.6% and 1.8% for HPLC and 2.5% and 4.8% for CE, respectively. The accuracy of the methods ranged from 98.8% to 102.3% for HPLC and from 95.9% to 108.2% for CE.

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권5호
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.

랫드에 있어서 [3H] pteroylglutamic acid 의 정맥주사후(靜脈注射後) 담즙중(膽汁中) 활성대사물(活性代謝物)에 관한 연구(硏究) (Active metabolites in rat bile after intravenous injection of [3H] pteroylglutamic acid)

  • 신호철;시모다 미노루;코쿠에 에이치
    • 대한수의학회지
    • /
    • 제33권4호
    • /
    • pp.605-609
    • /
    • 1993
  • 항암치료의 조절인자로서 중요시되는 활성엽산대사물의 장간(腸肝)순환동태를 규명하기 위해 랫드에 $[^3H]pteroylglutamic$ acid(PteGlu)를 정맥주사한 후 고성능 액체 크로마토그래피법(HPLC)을 이용해 담즙중 활성대사물에 관해 조사하였다. HPLC-liquid scintillation counting법의 분석결과, 현저한 다섯개의 방사활성 피크가 출현, 이들은 $H_4PteGlu$, $10-HCO-H_4PteGlu$, $5-CH_3-H_4PteGlu$와 paraaminobenzoyl glutamate(pABG), PteGlu로 각각 동정되었다. 전자 3물질의 활성엽산대사물의 동정은 표준물질과의 비교분석에 의해 HPLC-전기화학검출기를 이용한 retention time profile 및 hydrodynamic, Voltammogram의 일치성 그리고 HPLC-photodiode array분석에 의한 흡광스펙트럼의 일치성에 근거하였다. 후자 그 물질의(pABG 및 PteGlu) 동정은 흡광스펙트럼의 일치성에 근거하였다. 랫드 담즙중$[^3H]PteGlu$의 활성엽산대사물로서 $H_4PteGlu$의 존재가 처음으로 밝혀졌다.

  • PDF

High Performance Liquid Chromatography-Diode Array Detector(HPLC-DAD)에 의한 가미홍화탕 (KH-19)의 지문 분석 (Fingerprint of Marker Substances in Gami-Honghwa-Tang(KH-19) by HPLC-DAD)

  • 유영법;윤유식;조기호
    • 대한한의학회지
    • /
    • 제25권3호
    • /
    • pp.45-54
    • /
    • 2004
  • Objectives : This study was aimed to evaluate marker substances in Gami-Honghwa-Tang (KH-19) by high performance liquid chromatography-photodiode array detector (HPLC-DAD). Gami-Honghwa-Tang is composed of nine crude herbs, Rehmanniae Radix Preparata, Angelicae Gigantis Radix, Cnidii Rhizoma, Paeoniae Radix, Corni Fructus, Moutan Cortex Radicis, Lycii Fructus, Carthami Flos and Glycyrrhizae Radix. Methods : The separation was performed on an Aquasil C18 (4.6×250mm) column by gradient elution with 0.05% TFA in H2O - 0.05% TFA in acetonitrile (0 min 100:0, 20 min 90:10, 40 min 70:30, 60 min 50:50, 80 min 0:100, 90 min 100:0) as the mobile phase at a flow-rate of 1.0 ml/min with detection at 190-800nm. Also we examined the contents for bacteria, pesticide residue and harmful heavy metals. Results : HPLC-DAD was employed to determine the quantities and the qualities of several marker substances such as 5­hydroxymethyl-2-furaldehyde (5-HMF), paeonol, loganin, paeoniflorin, glycyrrhizin, and decursin in the KH-19. There were no bacterial contents, pesticide residues, or harmful heavy metals. Conclusions : We suggest these results could be a useful evidence for quality control of KH-19. This method permits fingerprints of selected individual marker substances from herbal prescriptions without derivatization, multiple purification steps, or lengthy separation times.

  • PDF