• Title/Summary/Keyword: High-efficiency operation

Search Result 1,924, Processing Time 0.025 seconds

Sensorless Starting Method and Fuel Pressure Control of BLDC Motor for Fuel Pump of Vehicle (자동차 연료 펌프용 BLDC 모터의 센서리스 기동 및 연료 압력 제어)

  • Chang, Jin-Wook;Yoon, Duck-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.114-121
    • /
    • 2013
  • High efficiency operation is required for motors of vehicle to increase fuel efficiency due to the regulation of exhaust gas. This paper presents a control method of fuel pressure to increase fuel efficiency and a sensorless control method of BLDC motor to get higher efficiency than conventional brushed DC motor. Initial rotor position of BLDC motor is detected from current value that is occurred by test voltage pulse and rotor is accelerated by defined sequence to enter sensorless operation mode. The algorithm to control flow rate of fuel pump uses PI controller that is control motor speed to maintain the target fuel pressure commanded by ECU.

Performance Analysis of High Efficiency DC-DC Chopper added in Electric Isolation (고효율 절연형 DC-DC 초퍼의 특성해석)

  • Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Choon-Sam;Jung, Do-Young;Kim, Soo-Kwang
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.115-117
    • /
    • 2007
  • This paper is analyzed for DC-DC chopper performance of high efficiency added in electric isolation. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching for a partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of chopper is high. And the proposed chopper is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed chopper is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper is verified by digital simulation and experimental results.

  • PDF

Quasi-Resonant PWM Converter Controlled by Constant Frequency (일정한 주파수로 제어되는 쿼지 공진형 PWM 컨버터)

  • Joung, Gyubum
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.2
    • /
    • pp.28-32
    • /
    • 2017
  • In this paper, a quasi-resonant PWM converter, which is controlled by constant frequency, has been suggested. As quasi-resonant converter, the switches of the suggested converter has soft switching characteristics, which can operate to high frequency with high efficiency. Comparing with varied controlled frequency of quasi-resonant converter for controlling output voltage, the suggested converter has advantages which optimize filter and EMI filter design at constant switching frequency. The converter has been analyzed by switch mode analysis which verified soft switching operation. Also, the PWM operation and characteristics of the converter are verified by simulation and experiment of 100 kHz DC-DC converter.

Excitation Voltage Control of SRM with Multi-Level Inverter (멀티레벨 인버터를 이용한 SRM의 여자전압제어)

  • Kang Yu-Jung;Lee Sang-Hun;Park Sung-Jun;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.29-32
    • /
    • 2001
  • The application of SRM(Switched Reluctance Motor) is dramatically increasing due to a simple mechanical structure, high efficiency and a good high speed characteristics. To control high conduction ratio in motor operation and regenerative voltage in the generator operation multi-level voltage control is effective. This paper proposes multi-level inverter to have a maximum conduction ratio of SRM. The proposed method is verified by experiments.

  • PDF

Design of Power Supply for Green PC using Low Voltage High Current LLC Resonant Converter (저전압 대전류 LLC 공진형 컨버터를 이용한 그린 PC용 전원공급장치 설계)

  • Yoo, Young-Do;Kim, In-Dong;Nho, Eui-Cheol;Ryu, Myung-Hyo;Baek, Ju-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • This paper proposes a low voltage high current LLC resonant converter for Green PC. Green PC is composed of a lot of blade PCs, and it is a centralized system to manage them in computer center. Green PC should require that its power supplies have several characteristics such as low output voltage, high output current, and high power conversion efficiency. Conventional PSFB (Phase Shift Full Bridge) converter is usually used as DC/DC converter for computer power supply because it has high power conversion efficiency thanks to ZVS (Zero Voltage Switching) operation under middle and high load conditions. However, this converter has some problems such as large switching noise and limitation of ZVS operation under light load condition. In order to improve the performance of power supply for Green PC, a new power supply using popular high efficiency LLC resonant converter for low voltage and high current application is proposed in this paper. The proposed power supply has ZVS capability over the entire load range, thus resulting in good efficiency and high switching frequency. Experimental results verify the performance of the proposed power supply for Green PC using 2[kW] (19[V], 105[A]) rated prototype converter.

An Analysis of Efficiency in Major University Hospitals in Domestically Capital Area Through DEA Analysis (DEA분석을 통한 국내 수도권 주요 대학병원의 효율성 분석)

  • Park, Byeong-Tae;Lee, Dong-Hyeon
    • Korea Journal of Hospital Management
    • /
    • v.16 no.4
    • /
    • pp.35-66
    • /
    • 2011
  • This study analyzed efficiency by utilizing DEA analytical technique centering on materials for 2009 of 20 major university hospitals in capital area. Input variables were utilized professor & full-time doctor, resident, nurse & number of bed hospitals. Output variables were analyzed by dividing number of annual outpatients & number of annual inpatients, and annually total outpatient profit & inpatient profit into a model of the standard for number of patients and the standard for medical profit. DEA analysis was elicited efficiency score by applying CCR, BCC, BFG, scale profit, and SE model. Through t-test after eliciting efficiency score, the implications were suggested by comparing efficiency between DMU in Seoul and DMU in capital area, by comparing between high-class general hospitals and general hospitals, and by comparing between high-class general hospitals in Seoul and 5 big hospitals. As a result of analysis, the major university hospitals in capital area showed high efficiency as a whole close to "1," but indicated low efficiency relatively in CCR field. Thus, the expansion in scale within capital area was indicated to reach the limit. Second, in a model of analyzing the standard for number of patients, the medical institutions, which are being operated efficiently, were indicated to be 10 DMUs. In the standard for medical profit, 12 DMUs were analyzed to be operated efficiently. Third, the efficiency in general hospital was higher than high-class general hospital. Thus, the efficiency of operation was indicated to be more important than scale. Also, large high-class hospitals(big 5) where are located in downtown Seoul showed the higher efficiency than other general high-class general hospitals, but were indicating very low efficiency in some DMUs. Fourth, as a result of generalizing and evaluating the number of patients and the medical profit, the efficient DMU was indicated to be more when analyzing on the basis of medical profit than the standard for number of patients. Thus, major university hospitals in capital area were indicated to make more effort for section in medical profit. Based on the analytical results of efficiency, a strategy for reinforcing efficiency in inefficient DMU was indicated to be needed a strategy of creating customers for promoting number of patients and a strategy for making operation efficient for increasing profitability.

  • PDF

High gain and High Efficiency Power Amplifier Using Controlling Gate and Drain Bias Circuit for WPT (무선전력전송용 게이트 및 드레인 조절 회로를 이용한 고이득 고효율 전력증폭기)

  • Lee, Sungje;Seo, Chulhun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.52-56
    • /
    • 2014
  • In this paper, a high-efficiency power amplifier is implemented using a gate and drain bias control circuit for WPT (Wireless Power Transmission). This control circuit has been employed to improve the PAE (Power Added Efficiency). The gate and drain bias control circuits consists of a directional coupler, power detector, and operation amplifier. A high gain two-stage amplifier using a drive amplifier is used for the low input stage of the power amplifier. The proposed power amplifier that uses a gate and drain bias control circuit can have high efficiency at a low and high power level. The PAE has been improved up to 80.5%.

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.

Maximum-Efficiency Tracking Scheme for Piezoelectric-Transformer Inverter with Dimming Control

  • Nakashima Satoshi;Ogasawara Hiroshi;Kakehashi Hidenori;Ninomiya Tamotsu
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.7-10
    • /
    • 2001
  • This paper provides a solution for the problem of efficiency decrease caused by load variation. A novel control scheme of tracking the PT's operation frequency for the maximum efficiency is proposed. As a result, a high efficiency over $80\%$ has been achieved even under the output-current decrease down to $10\%$ of the full load current.

  • PDF

EFFICIENCY ANALYSIS OF A DOMAIN DECOMPOSITION METHOD FOR THE TWO-DIMENSIONAL TELEGRAPH EQUATIONS

  • Jun, Younbae
    • East Asian mathematical journal
    • /
    • v.37 no.3
    • /
    • pp.295-305
    • /
    • 2021
  • In this paper, we analyze the efficiency of a domain decomposition method for the two-dimensional telegraph equations. We formulate the theoretical spectral radius of the iteration matrix generated by the domain decomposition method, because the rate of convergence of an iterative algorithm depends on the spectral radius of the iteration matrix. The theoretical spectral radius is confirmed by the experimental one using MATLAB. Speedup and operation ratio of the domain decomposition method are also compared as the two measurements of the efficiency of the method. Numerical results support the high efficiency of the domain decomposition method.