• 제목/요약/키워드: High-current impulse current

검색결과 124건 처리시간 0.025초

배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구 (A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • 한국전기전자재료학회논문지
    • /
    • 제15권2호
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

대전류 임펄스에 대한 소규모 메쉬전극의 과도접지임피던스 특성 (Characteristics of Transient Ground Impedance of a Scaled Grounding Grid on the High Current Impulse)

  • 이태형;조성철;엄주홍;유양우;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1418_1419
    • /
    • 2009
  • This paper presents the transient impedance when high current impulse up to 5 kA is applied to a scaled grounding grid in test field. For a realistic analysis of transient impedance on the high current impulse in the ground systems, grounding electrode installed outdoors and impulse current generator was used. The results were discussed based on its voltage and current trace, impulse impedance and V-I curve.

  • PDF

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.

배전급 피뢰기(18kV, 5kA)용 ZnO 바리스터 소자 개발 (Development of ZnO Varistor for Distribution Surge Arrester (18kV, 5kA))

  • 박춘현;윤관준;조이곤;정세영;서형권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.212-216
    • /
    • 2000
  • ZnO varistors for distribution surge arrester (18kV, 5kA) were developed and tested microstructure and electrical characteristics. Microstructure of ZnO varistor was consisted of ZnO grain, spinel phase and Bi-rich phase. Average grain size of ZnO varistor was $\mu\textrm{m}$ Reference voltage and lightning impulse residual voltage of ZnO varistor exhibited a good haracteristics above 5.5kV and below 11.56kV, respectively. Consequently, discharge capacity which is the most important characteristics of ZnO varistor for surge arrester exhibited excellent properties above 70kA at twice high-current impulse test. Moreover, variation rate of reference voltage and lightning impulse residual voltage showed below 5% and 2% after high-current impulse test, respectively. Leakage current and watt loss of ZnO varistor will not increase during accelerated aging test at stress condition, such as 3.213kV/$115^{\circ}C$/1000h.

  • PDF

초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가 (Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;윤한수;김석수
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성 (Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;유대훈;이유정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구 (An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse)

  • 이동훈;송화영
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

대형 봉상 접지전극의 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods)

  • 이복희;장근철;이동문;정동철;이승칠;안창환;정용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1849-1851
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flow into the grounding system, the ground impedance is significantly increased because of the inductive behavior. This paper presents how the impulse current works on the long vertical ground electrodes. The different shape of current was impressed between ground rods and auxiliary electrode by using impulse generator and the ground impedance was calculated from the ground potential rise.

  • PDF

파라데이효과를 이용한 임펄스 대전류 측정 (Detect to Impulse Large Current based on faraday Effect)

  • 박해수;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.505-507
    • /
    • 1995
  • Applications of the fiber optic sensing are glowing rapidly, particularly in situations where size, weight, speed, and immunity to electromagnetic interference are important considerations. The fiber optic current sensors have been developed for low frequency(60Hz) metering in electric power systems. But we try measure to high frequency large current by fiber optic current sensor based on Bi substituted rare earth iron garnet. In this paper, we report the linearity to 500 amperes and frequency response of signal processor and a result of detection the standard impulse large current of fiber optic impulse sensor system.

  • PDF