• Title/Summary/Keyword: High-Strength Bars

Search Result 268, Processing Time 0.04 seconds

An Experimental Study on the Evaluation of Shear Performance of PVA Fiber Reinforced RC Deep Beam with High Strength Headed Rebar

  • Kim, Seunghun;Lee, Kyuseon;Lee, Yongtaeg
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.109-115
    • /
    • 2017
  • This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shear experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-span ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large difference depending on existence of shear reinforcing bar. Therefore, theoretical shear strength followed by CEB code underestimates experimental shear strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strength of bar.

Shear Strength of Vertical Joints in Precast Concrete Panel with Shear Key (전단키를 갖는 프리캐스트 콘크리트 패널 수직접합부의 전단강도)

  • Lee, Sang-Sup;Park, Keum-Sung;Bae, Kyu-Woong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.151-158
    • /
    • 2019
  • A concrete core is used widely as lateral stability systems in high-rise modular buildings. As an alternative to traditional cast in-situ core, the precast concrete(PC) method can accelerate the construction of reinforced concrete cores. A core composed of precast elements differs from a in-situ core in having connections between the precast elements. The typical vertical connection between PC panels is consisted of shear keys, loop bars, lacer bars and grout. In this study, the effect of vertical connection components on shear strength is investigated experimentally. The test results show that the contribution to the shear strength is greater in order of grout strength, shear keys, lacer bars and loop bars. In addition, the numerical models to estimate the shear strength according to two crack patterns in the vertical joint of the PC panels are derived. The feasibility of the numerical models is evaluated by comparing the estimated shear strength and the test results.

Cyclic Loading Test for Shear Strength of Low-rise RC Walls with Grade 550 MPa Bars (550 MPa 급 철근을 적용한 낮은 철근콘크리트 벽체의 전단강도를 위한 반복하중 실험)

  • Park, Hong-Gun;Lee, Jae-Hoon;Shin, Hyun-Mock;Baek, Jang-Woon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.601-612
    • /
    • 2013
  • In the construction of nuclear power plants using massive walls, the use of high-strength re-bars for shear design is necessary to enhance the constructability and economy. In this study, low-rise walls (aspect ratio of 1.0) with grade 550 MPa bars were tested under cyclic loading to investigate the shear capacity and deformation capacity. The test parameters were the grade of horizontal re-bars (550 MPa, 420 MPa), strength of concrete compressive strength (46 MPa, 70 MPa), horizontal/vertical reinforcement ratio, use of lateral confinement hoops, shape of cross section, and failure modes (shear failure before or after flexural yielding). The test results were compared with those of walls with grade 420 MPa bars and predicted strength by current design codes. The results showed that the shear strength of the walls with 550 MPa bars was comparable to that of the walls with 420 MPa bars though the safe margin slightly decreased. ACI 349 provides underestimated shear strength for the walls with 550 MPa bars. In case of the wall with flexural yielding, a large deformation capacity was achieved. This result indicates that the ACI 349 provisions can be safely applied to seismic design of the low-rise walls (aspect ratio of 1.0) with grade 550 MPa bars.

Bond-Strengthening Hooks for RC Members with High Strength Spirals

  • Kim Kil-Hee;Sato Yuichi
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.835-842
    • /
    • 2005
  • This paper presents an experimental investigation of bond-strengthening hooks as a new method to increase bond strength along flexural reinforcing bars in reinforced concrete (RC) beams and columns. The RC members, which consisted of 1,300 MPa-class spirals as shear reinforcement, often suffered from bond splitting failure. The proposed method attempts to increase confining stiffness around the flexural bars by placing U-shaped hooks and to prevent premature bond splitting failure. Twelve specimens with varied amounts and sizes of the hooks were prepared to verify the strengthening effectiveness under monotonic and cyclic loading conditions. The test result indicated that the hooks increased the bond strength along the flexural bars although the strengthening effectiveness was limited by effective reinforcement ratio $P_{be}$. This limit is determined by size of stress-transmitting zones of concrete around anchors of the hooks. Anchors of the hooks are recommended to be longer than twelve times the hook diameter and inserted deeper than a quarter of the member depth (D/4). Proposed design equations provide modest estimates of the shear strengths.

Evaluation of structural behavior of RC columns strengthened with high-strength steel bars (고강도 횡보강철근을 사용한 철근 콘크리트 기둥의 구조 거동 평가)

  • Lee, Jang-Hee;Kim, Do-Jin;Baek, Seung-Cheol;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.103-104
    • /
    • 2010
  • There are two conflicting opinions about effect of confinement using High-Strength transverse reinforcement. This paper verifies evaluation of structural behavior of RC columns strengthened with high-strength steel bars by performing an experimental study of 15 large-scale column confined by high-strength transverse reinforcement tests.

  • PDF

Shear Strength of SFRC Deep Beam with High Strength Headed Reinforcing Tensile Bars (고강도 확대머리 인장철근을 가지는 SFRC 깊은 보의 전단강도)

  • Kim, Young-Rok;Lee, Chang-Yong;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.111-117
    • /
    • 2019
  • Shear experiments were carried out to evaluate shear performance of SFRC deep beams with end-anchorage of SD600 high strength headed reinforcing tensile bars. The experimental variables include the end-anchorage methods of tensile bars (headed bar, straight bar), the end-anchorage lengths, and the presence of shear reinforcement. Specimens with a shear span ratio of 1 showed a pattern of the shear compression failure with the slope cracks progressed after the initial bending crack occurred. Specimens with end-anchorage of headed bars (H-specimens) showed a larger shear strengths of 5.6% to 22.4% compared to straight bars (NH-specimens). For H-specimens, bearing stress reached 0.9 to 17.2% of the total stress of tensile bars up to 75% of the maximum load, and reached 22.4% to 46%. This shows that the anchorage strength due to the bearing stress of headed bars has a significant effect on shear strength. The experimental shear strength was 2.68 to 4.65 times the theoretical shear strength by the practical method, and the practical method was evaluated as the safety side.

Study on the Development Design Criteria of High Relative Rib Area bars (높은 마디면적비 철근의 부착강도에 따른 정착설계 연구)

  • Park, Sung-Gyu;Hong, Geon-Ho;Choi, Oan-Chul;Hong, Gi-Suop
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.270-273
    • /
    • 2006
  • Bond between reinforcing bar and the surrounding concrete is made up of three components. There are chemical adesion, friction, and mechanical interaction between the rib of the bar and the surrounding concrete. bond of deformed bars depends primarily on the beraing of rib deformation anainst the surrounding concrete. The final objective of the study is to enhance structural stability, and workability thorough increasing the bond strength between deformed bar and surrounding concrete. The results of this study will be used to shorten bond and development length by $20{\sim}30$ percent and it will facilitate to use of high strength and high-relative rib area bars.

  • PDF

Evaluation of Structural Behavior of Reinforced Concrete Exterior Beam-Column Joints with High-Strength Concrete (고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가)

  • Lee, Bum-Sik;Kim, Kyung-Duk;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.72-81
    • /
    • 2014
  • This paper reports the test results of reinforced concrete exterior beam-column joints with high-strength concrete. The main parameters of eight specimens were joint failure modes, the compressive strength of concrete, and the head shapes of steel bars. All specimens were designed according to ACI 352R-02 design recommendations. Two types of failure modes were considered; J-failure and BJ-failure. The longitudinal steel bars were anchored by 90 degree standard hooks or headed reinforcement. Experimental results indicated that the current ACI design recommendation limited by the compressive strength of concrete somewhat underestimated the strength of beam-column joints with high-strength concrete. In the specimens showed joint shear failure, the strength of beam-column joints with headed bars was approximately 10 percent higher than that of joints with 90 degree standard hooks.

Bond Strength Analysis of High Relative Rib Area Bars Using Decreasing Bearing Angle Theory (지압각 감소이론을 이용한 높은마디면적 철근의 부착강도 해석)

  • Yang, Seung-Yul;Seo, Dong-Min;Park, Young-Su;Hong, Gun-Ho;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.185-188
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond strength of ribbed reinforcing bars tends to split concrete cover, by wedging action, or shear the concrete in front of the ribs. In this study, using a reducing bearing angle theory, bond strengths of beam end specimen are predicted. Values of bond strength obtained using the analytical model are in good agreement with the bond test results. The analytical model provides insight into bond mechanism and the effects of bearing angle on the bond strength of deformed bars to concrete.

  • PDF

An Experimental Study on Bond Strength of High-Strength Reinforcing Bars with High Relative Rib Area (높은 마디면적 고강도 철근의 부착강도에 관한 실험적 연구)

  • Hong Geon-Ho;Choi Dong-Uk;Choi Oan-Chul;Hong Gi-Suop
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.375-384
    • /
    • 2005
  • The effects of bar deformation properties on bond of steel reinforcing bars to concrete are experimentally studied to predict the bond strength. Based on the previous research about high relative rib area, bond strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. But, the equations in Korean code provisions to estimate development and splice length do not include these specifications of reinforcing bars. So the purpose of this paper is to determine the effect of relative rib area to the bond strength. This paper describes 2 kinds of experimental researches. Thirty beam-end specimens were tested to investigate the effects of bar size and relative rib areas ranging from 0.112 to 0.162. And, twelve lap-splice beam specimens were tested to the same variables. Each test results are normalized and compared with the proposed equations of ACI 408 committee. The results show that bond strength is increased as bar size and the relative rib area(Rr) increase. The distribution of flexural cracks and failure aspect do not appear to be affected by $R_r$.