• Title/Summary/Keyword: High-Speed Transmission Line

Search Result 167, Processing Time 0.022 seconds

Fault Location Algorithm with Ground Capacitance Compensation for Long Parallel Transmission Line (장거리 병렬 송전선로용 대지 정전용량 보상에 의한 고장점 표정 알고리즘)

  • Park, Chul-Won;Kim, Sam-Ryong;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • This paper deals with an improved fault location algorithm with compensation ground capacitance through distributed parameter for a long parallel T/L. For the purpose of fault locating algorithm non-influenced by source impedance and fault resistance, the loop method was used in the system modeling analysis. This algorithm uses a positive and negative sequence of the fault current for high accuracy of fault locating calculation. Power system model of 160km and 300km long parallel T/L was simulated using EMTP software. To evaluate of the proposed algorithm, we used the several different cases 64 sampled data per cycle. The test results show that the proposed algorithm was minimized the error factor and speed of fault location estimation.

Modeling of Arbitrary Shaped Power Distribution Network for High Speed Digital Systems

  • Park, Seong-Geun;Kim, Jiseong;Yook, Jong-Gwan;Park, Han-Kyu
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.324-327
    • /
    • 2002
  • For the characterization of arbitrary shaped printed circuit board, lossy transmission line grid model based on SPICE netlist and analytical plane model based on the segmentation method are proposed in this paper. Two methods are compared with an arbitrary shaped power/ground plane. Furthermore, design considerations for the complete power distribution network structure are discussed to ensure the maximum value of the PDN impedance is low enough across the desired frequency range and to guide decoupling capacitor selection.

  • PDF

Twinax Cable Modeling for Use in HANbit ACE64 ATM Switching Systems (HANbit ACE64 ATM 교환기 시스템의 Twinax 케이블 모델링)

  • 남상식;박종대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12A
    • /
    • pp.1985-1991
    • /
    • 1999
  • In this paper, complete and general two-port lumped Spice-network model is developed for a lossy transmission line. This model is realized as a Spice subcircuit, by means of standard lumped network elements and mathematical functions. It is used as a component in the time-domain simulation of a high-speed data transmission line such as IMI(Inter Module Interface) data path in HANbit ACE 64 ATM switching system. The only required Spice network elements are resistance and frequency-dependent controlled-voltage sources. Such frequency-dependent sources are realized by utilizing the standard Hspice mathematical functions FREQ, DELAY, and POLY.

  • PDF

A New BIM Line Code for High Speed Binary Data Transmission (고속 이진 데이터 전송을 위한 새로운 BIM 선로부호)

  • 정희영;오행석;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12A
    • /
    • pp.1939-1947
    • /
    • 1999
  • This paper proposes new line code BIM (Bit Insertion and Manipulation) that is designed to overcome the problems of existing line codes. The block code, one of typical existing line code, has good transmission performance but difficulty in implementation. The other typical existing line code, bit insertion code, is easy to implementation but has bad transmission performance. BIM code in this paper could provide not only good performance but also provides simplicity in the implementation by combining the good points of block code into it of bit insertion code properly. In this paper, 5B6B type BIM code is designed. Designed 5B6B BIM code shows good transmission performance such $\pm$2 DSV, 0 RSD, 7 maximum run length and also it can be implemented under 2000 gates and need only 1 bit redundancy.

  • PDF

A Control of CVT Hydraulic System using Embedded System (임베디드 시스템을 이용한 CVT 유압시스템 제어)

  • Han, K.W.;Ryu, W.S.;Jang, I.G.;Jean, J.W.;Kim, H.S.;Hwang, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 2007
  • The continuously variable transmission (CVT) of which speed ratio can change continuously in a fixed range has the benefits of low fuel consumption and exhaust gas because it enables the engine of a vehicle to operate in a high efficiency range regardless of vehicle speed. The speed ratio of belt type CVT is controlled by adjusting line pressure. The one of the line pressure control methods, mechanical-hydraulic control is usually adopting VDT's control method, in which the secondary solenoid valve has two functions both a regulator and a line pressure controller. However, this control method could not show the high performance of CVT with optimal driving capability because of the limitation of simple control algorithm, and it could not gain market share sufficiently in spite of the advantage of CVT with low fuel consumption. On the other hand, the electro-hydraulic control method gives the enhancement of power performance and low fuel consumption by implementing various driving mode using the proportional control or PWM control. The key of CVT technique is to develop a control algorithm of the electro-hydraulic solenoid valve in order to implement the speed ratio efficiently. In this paper, the line pressure control algorithm is proposed and the hydraulic system is controlled using metal belt type CVT test rig and the embedded ECU platform.

  • PDF

A Study on Forward Error Correction of Long-Distance Submarine Optical Communication Systems (장거리 해저 광통신시스템의 순방향에러정정 기술 연구)

  • Jung, Jae-Jin;Lee, Young-Sun;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.170-176
    • /
    • 2008
  • According to the development of Internet, DWDM system needs to improve the performance for long distance transmission international optical signals. For higher the transmission capacity, we have to raise the transmission speed and increase a number of channels. To make qualifications, there are a lot of technologies such as line coding, modulation, precious fiber, broadband amplification, dispersion and forward error correction. Especially, FEC has been considered as a progressive technology for long distance transmission to carry out high speed and large capacity traffic. This paper introduced the progress of each new generation of FEC and the way to employ by current system analyzed the coding gain.

  • PDF

NIBI Line Code for High-Speed Interconnection (고속 interconnection을 위한 NIBI 선로 부호)

  • Koh, Jae-Chan;Lee, Bhum-Cheol;Kim, Bong-Soo;Choi, Eun-Chang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.8
    • /
    • pp.1-10
    • /
    • 2001
  • This paper describes new line code algorithm, called NIDI(Nibble Inversion mock Inversion) which is well suited for interconnection and transmission technology, The proposed line code which includes only one redundancy bit serves primary features of line code and synchronization patterns for byte or frame synchronization in interconnection, Also, this line code provides in-band signals and speciaI characters.

  • PDF

Design and Analysis of Large Induction Motor Control Coping with Voltage Sag (순간전압강하 극복을 위한 대용량 유도전동기 제어방식 설계 및 해석)

  • Cho, Sung-Don;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1056-1058
    • /
    • 1998
  • Voltage dips caused by transmission system faults are usually of a short duration. High speed relaying and breaker operation will typically limit the disturbance to 0.1 seconds. Most motor controllers obtain their control power directly from the bus by means of a control transformer. Under this condition, a voltage dip can cause the contactor to drop out. disconnecting the motor from the line. The rapid re-energizing of the controller is in effect a fast reclosure which may result in motor damage. The time delay re-energizing of controller will result in a greater loss of speed and possibly loss of stability. Other means of controller can be used to prevent the motor from being disconnected from line during the fault. This can be accomplished by DC power controller or mechanically latched controller. This paper demonstrates that DC power controller or mechanically latched type controller to prevent the motor from being disconnected from line during the fault is, the most effective in minimizing speed reduction, transient motor current, transient motor torque and transient shaft torque by EMTP calculation.

  • PDF

Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel (고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석)

  • 김선효;김상태;이영철;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2003
  • This paper shows the results of emissive electromagnetic field characteristics on medium voltage power line(22.9 kV). The measurements were taken when communications signals were coupled into the 22.9 kV main wire of medium voltage power-line in a frequency range of 9 kHz to 30 MHz. The results of the measurement are as follows-emissive electromagnetic Held characteristics from multi carrier signals were superior to a single carrier signal. And we confirmed the PLC transmission distance was 1.8 km when multi-carrier transmission power was 20 dBm. Electric field strength was under the 40 dBuV/m at 30 MHz when 10 m method was measured.

Study on Very High-Rate Power Line Communications for Smart Grid (스마트그리드를 위한 초고속 전력선통신기술 연구)

  • Choi, Sung-Soo;Oh, Hui-Myoung;Kim, Young-Sun;Kim, Yong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1255-1260
    • /
    • 2011
  • In this paper, we study on the reliability of Very High-rate Power Line Communication (VH-PLC) for Smart Grid, so that the resultant data rate is over 400Mbps at a physical layer. Firstly, reviewing the research trend of the PLC, we discuss the required techniques for supporting the Smart Grid. Considering a pre-specification with the value of several parameters, we investigate a multi-carrier modulation technique to overcome limitations of higher rate transmission under power line channel environments. Then, we propose a system specification of the VH-PLC in the sense of enhancing two features. One is resolving the problem of the co-existence of the deployed high-speed PLC according to the published standardization of KS X 4600-1 in Korea. The other is getting better performance on the grid adopting the diverse element techniques, such as multi-carrier modulation, a subcarrier utilization mode, a variable rate LDPC (Low Density Parity Check) code, and a time and frequency diversity technique. Further, a simulation tool, composed of an Event-Driven simulator and a Time-Driven simulator, is developed for the purpose of verifying the system performance and continuously cross-checking the test bench signal of the proposed VH-PLC system.