• Title/Summary/Keyword: High-Resolution Computed Tomography

Search Result 165, Processing Time 0.031 seconds

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Is Preventive Bilateral Surgery Needed in Case of Bilateral Bullae on HRCT at Unilateral Primary Spontaneous Pneumothorax (일차성 자연기흉의 고해상 CT에서 보이는 반대편 기포의 예방적 기포절제술이 필요한가?)

  • Han, Jong-Hee;Kang, Min-Woong;Yu, Jeong-Hwan;Kim, Yong-Ho;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.215-219
    • /
    • 2007
  • Background: Due to the advancement of video assisted thoracoscopic techniques, an operation for primary spontaneous pneumothorax is now considered a common procedure. However, whether a preventive operation is necessary when a contralateral bulla is found on High Resolution Computed Tomography (HRCT) at the time of the first primary spontaneous pneumothorax attack is still unknown. In this retrospective study, it was our intension to find whether contralateral bullae are related to the occurrence of pneumothorax. Material and Method: Between January 1999 and April 2006, 550 patients were admitted to the Chungnam University hospital with primary spontaneous pneumothorax, which was confirmed by the HRCT scans in 190 patents. In these 190 patients, 159 had not received a bilateral operation after their first primary spontaneous pneumothorax attack. In these 159 patients, the relationship between the presence of contralateral bullae and the occurrence of pneumothorax was measured. Result: In these 159 patients, 67 had contralateral bullae confirmed inform the HRCT scan, and 92 had no visible contralateral bullae, During the follow up period, 6 patients (8.9%) with contralateral bullae had an occurrence of contralateral pneumothorax, and 5 patients (5.4%) without contralateral bullae had an occurrence of contralateral pneumothorax. (p=0.529 [Fisher's exact test]) Conclusion: In patients with unilateral primary pneumothorax, an HRCT scan is a useful way of confirming contralateral pulmonary bullae. However, the presence of bullae is not a significant predictive sign of an occurrence of contralateral pneumothorax. Also, surgery for pneumothorax is not completely uncomplicated, and bilateral surgery is still doubtful. A further prospective study will be required to find the relationship between the bullae found on HRCT and the occurrence of pneumothorax.

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

A Case of Idiopathic Interstitial Pneumonia in Childhood (소아 특발성 간질성 폐렴 1례)

  • Lee, Su-Jin;Shin, Eon-Woo;Park, Eun-Young;Oh, Phil-Soo;Lee, Kon-Hee;Kim, Kwang-Nam;Shin, Ho-Seung;Lee, Il-Seung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.3
    • /
    • pp.327-332
    • /
    • 2005
  • Interstitial lung disease refers to a group of pulmonary disorders characterized by inflammation of the interstitium, derangements and loss of alveolar capillary units leading to disruption of alveolar gas exchange, which induces symptoms of restrictive lung disease. Cases of interstitial pneumonia in children are uncommon and mostly have unknown causes. We have experienced an 8-year old boy who had symptoms of cyanosis, dry cough, dyspnea and abrupt weight loss. He had not been exposed to organic dusts, allergens or any other systemic disease infections. Chest radiology showed diffuse ground glass opacity in both lung fields. High resolution computed tomography(HRCT) showed multiple small patchy areas of consolidation with an underlying ground glass appearance in both lungs. The pathologic findings of lung biopsy tissue showed patchy areas of interstitial fibrosis, alveolar obliteration and nodular fibrotic areas, strongly suggesting interstitial pneumonia. No specific finding of viral inclusion or any other evidence of infection was found under electromicroscopy. We used peak flow meters to compare functional improvement. Forced expiratory volume in one second ($FEV_1$) was decreased to 25 percent of predicted value. The boy was given treatment with prednisone and showed improvements in HRCT findings after two months. He was able to tolerate easy exercise in school and showed clinical improvements after one year of follow up.

A Case of Bronchus-Associated Lymphoid Tissue(BALT) Lymphoma Treated with Lobectomy (폐엽절제를 통한 BALT 림프종 치료 1 예)

  • Choi, Won Sub;Cho, Jae Hyun;Hwang, Young Il;Jang, Seung Hun;Kim, Dong-Gyu;Jun, Sun-Young;Min, Kwangseon;Lee, In Jae;Lee, Jae Woong;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.427-431
    • /
    • 2007
  • The bronchus-asociated lymphoid tissue(BALT) lymphoma is a low-grade primary malignant lymphoma that originates from bronchus associated lymphoid tissue. A 67-year-old woman was admitted for evaluation of cough, sputum, rhinorrhea which had persisted for one month. Physical examination showed decreased breathing sound on the left upper lung field. High resolution chest computed tomography demonstrated consolidation which showed air-bronchogram and surrounding ground glass opacity in left upper lobe. These findings implicated inactive tuberculosis, organizing pneumonia, or bronchiolo-alveolar carcinoma. The histologic findings from percutaneous needle aspiration biopsy revealed aggregated atypical small lymphoid cells with lymphoepithelial lesions. With immunohistochemical staining, the atypical lymphoid cells reacted positively with CD 20 antibody and negatively with CD 3 antibody. Thus, we could diagnosed her as a patient with BALT lymphoma. After left upper lobectomy, she has been well without recurrence of the disease for 14 months. In this country of Republic of Korea, it was the 1st case of BALT lymphoma surgically treated when histological diagnosis had been done. Based on this case, we wanted to demonstrate the importance of early histological diagnosis and treatment of BALT lymphoma.

Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion (CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석)

  • Chang, You-Song;Cho, Kil-Ho;Byun, Woo-Mock;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.127-134
    • /
    • 1993
  • Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.

  • PDF

A Case of Nonspecific Interstitial Pneumonia Associated with Systemic Lupus Erythematosus (전신성 홍반성 낭창에 병발된 비특이성 간질성 폐렴 1예)

  • Lee, Ho-Moeng;Hwang, Jae-Kyung;Park, Gae-Young;Park, Jeong-Woong;Park, Jae-Kyung;Jeong, Seong-Hwan;Nam, Gui-Hyun;Lee, Jae-Woong;Ha, Seung-Yeon;Lee, Han-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.6
    • /
    • pp.732-739
    • /
    • 2001
  • Systemic lupus erythematosus frequently has thoracic involvement among connective tissue diseases. One of the pleuropulmonary manifestations is diffuse interstitial lung disease including nonspecific interstitial pneumonia(NSIP). NSIP is a newly classified disease among interstitial lung diseases. Systemic lupus erythematosus has a better prognosis than usual interstitial peumonia(UIP) and responds well to steroids. In this report, a 34 year-old woman who complained of a dry cough, and exertional dyspnea for 2 months is described. The chest X-ray showed fine reticular opacities and a mild honeycomb appearance in both basal lungs. High resolution computed tomography(HRCT) showed bilateral patchy areas of ground-glass attenuation and a mild honeycomb appearance in the subpleural of both the lower and the middle portion of the lung fields. An open lung biopsy showed prominent lymphocytic interstitial inflammation and fibrosis with small areas with a honeycomb appearance. This case was diagnosed as NSIP associated with systemic lupus erythematosus and was managed with oral steroids. Here we report a case of nonspecific interstitial pneumonia associated with systemic lupus erythematosus confirmed by HRCT and an open lung biopsy with a review of the relevant literature.

  • PDF