• Title/Summary/Keyword: High voltage pulsed current

Search Result 112, Processing Time 0.025 seconds

Application Technologies of Pulsed Power with the High Voltage and Current (고전압.대전류 pulsed power의 이용기술)

  • Lee, Hyeong-Ho;Kim, Young-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1678-1680
    • /
    • 1997
  • The pulsed power with the high voltage and current can be used to the fields of high speed pulses of energy in different forms such as electric current and voltage, electron beam, ion beam, x-rays, gamma rays, heat, magnetics fields, sound and shock waves. This paper is directed mainly at electrical engineers working on production and practical application of high speed pulsed power with high voltage and current.

  • PDF

Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current (고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화)

  • Kim, Su-Hyon;Choi, Sug-Ju;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl;Kim, Gye-Yeop
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF

Inactivation of Listeria monocytogenes in Brine and Saline by Alternating High-Voltage Pulsed Current

  • Lee, Mi-Hee;Han, Dong-Wook;Woo, Yeon-I.;Uzawa, Masakazu;Park, Jong-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.7
    • /
    • pp.1274-1277
    • /
    • 2008
  • The inactivating efficiency of alternating high-voltage pulsed (AHVP) current was investigated in brine (20 w/v% NaCl) and saline (0.9 w/v% NaCl) inoculated with $1\times10^7$ cells/ml of Listeria monocytogenes. AHVP current at 12 V with 1 pulse completely inactivated L. monocytogenes in brine within 3 ms, while the bacteria in saline were fully inactivated by 10-pulsed electric treatment at 12 V within the same time. Electron microscopic observation demonstrated substantial structural damage of electrically treated L. monocytogenes in brine. These results suggest that AHVP treatment would be effective for the rapid and complete inactivation of L. monocytogenes in brine or saline solution.

Pulse energy high Power test of metal film resistor (메탈 필름 저항의 펄스 대전력 시험)

  • Son, Y.G.;Jang, S.D.;Kwon, S.J.;Oh, J.S.;Cho, M.H.;Lee, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2103-2105
    • /
    • 2005
  • Metal film type of resistor have been tested to invest maximum usable power at the pulsed high voltage and pulsed high current. Experiments were carried out using capacitor charging power supply and dump switch. Pulsed amplitude were varied from 1kV to 25kV. The peak current reached was 1kA. Datasheet are given for the limited pulsed power and energy for metal film type of resistor in nanosecond and microsecond time range. The experimental investigation of the threshold loading of the resistor in the high current and voltage pulsed mode has shown that the process of destruction of resistor has specific features for each mode. The mechanisms of failure and destruction of resistors under action of high-voltage and high-current pulses are discussed.

  • PDF

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

High-Voltage AlGaN/GaN High-Electron-Mobility Transistors Using Thermal Oxidation for NiOx Passivation

  • Kim, Minki;Seok, Ogyun;Han, Min-Koo;Ha, Min-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1157-1162
    • /
    • 2013
  • We proposed AlGaN/GaN high-electron-mobility transistors (HEMTs) using thermal oxidation for NiOx passivation. Auger electron spectroscopy, secondary ion mass spectroscopy, and pulsed I-V were used to study oxidation features. The oxidation process diffused Ni and O into the AlGaN barrier and formed NiOx on the surface. The breakdown voltage of the proposed device was 1520 V while that of the conventional device was 300 V. The gate leakage current of the proposed device was 3.5 ${\mu}A/mm$ and that of the conventional device was 1116.7 ${\mu}A/mm$. The conventional device exhibited similar current in the gate-and-drain-pulsed I-V and its drain-pulsed counterpart. The gate-and-drain-pulsed current of the proposed device was about 56 % of the drain-pulsed current. This indicated that the oxidation process may form deep states having a low emission current, which then suppresses the leakage current. Our results suggest that the proposed process is suitable for achieving high breakdown voltages in the GaN-based devices.

The Pulsed Id-Vg methodology and Its Application to the Electron Trapping Characterization of High-κ gate Dielectrics

  • Young, Chadwin D.;Heh, Dawei;Choi, Ri-No;Lee, Byoung-Hun;Bersuker, Gennadi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.2
    • /
    • pp.79-99
    • /
    • 2010
  • Pulsed current-voltage (I-V) methods are introduced to evaluate the impact of fast transient charge trapping on the performance of high-k dielectric transistors. Several pulsed I-V measurement configurations and measurement requirements are critically reviewed. Properly configured pulsed I-V measurements are shown to be capable of extracting such device characteristics as trap-free mobility, trap-induced threshold voltage shift (${\Delta}V_t$), as well as effective fast transient trap density. The results demonstrate that the pulsed I-V measurements are an essential technique for evaluating high-$\kappa$ gate dielectric devices.

Effect of High Voltage Pulsed Current on Edema Reduction (고전압 전기 자극의 부종 감소 효과)

  • Kim, Youn-Jung;Kim, Choel-Yong;Hong, Ju-Wan;Ahn, Duk-Hyun
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.61-66
    • /
    • 1994
  • The purpose of this study was to investigate the effect of a single treatment o voltage pulsed current (HVPC) on edema reduction. Hind limbs of 23 anesthetized were injured by dropping a 400 g weight onto the plantar aspects of the feet. On limb of each frog was randomly selected to receive 30 minutes of continuous, 12 cathodal HVPC at voltages 10 % less than motor threshold levels. Limb volumes measured by water displacement before trauma and at predetermined intervals hours posttrauma. Sources of significant differences were determined by t-test HVPC significantly (p<0.05) reduced edema formation. We hypothesize that HVP also be effective in controlling edema formation after impact injuries in humans.

  • PDF

Study on Measurement Technology for Equivalent Series Impedance of High-voltage Pulsed Power Capacitors (펄스파워용 고전압 커패시터 등가직렬 임피던스 측정에 관한 연구)

  • Lee, Byeong-Yoon;Lee, Byung-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.937-942
    • /
    • 2013
  • Equivalent series impedance of high-voltage pulsed power capacitor is one of the important electrical characteristics both for users and for capacitor manufacturers because it may have serious effects on the performance of pulse forming circuits. In this paper, definition of equivalent series impedance and factors which generate equivalent series impedance are reviewed. Theoretical analysis for the calculation of equivalent series impedance based on differential measurement method is described and calculation program has been developed. In order to acquire data which are necessary to calculate equivalent series impedance from discharging current waveform, charging-dischargig controller has been manufactured. Measurement results of equivalent series impedance for high voltage pulsed power capacitor have been given.

An in Vivo Study of High Voltage Pulsed Current on pH in the Healing Wound Bed

  • Song, Byung-H.
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.173-178
    • /
    • 1999
  • The purpose of this study was to determine the effect of High Voltage Pulsed Current on pH in the healing wound bed. Seven adults, four males and three females, were studied with a total of fifty-five viable treatment sessions. Using a Cardy Digital pH meter, we measured the pH in the wound bed following saline rinse both prior to treatment and after a forty-five minute treatment. Analysis of all viable records(n=54) did not show a significant change in pH(p=0.82). The mean pH change in NoN-Smokers(-0.14) was more acidic when compared to the mean pH change in smokers(0.27) which was more alkaline.

  • PDF