• Title/Summary/Keyword: High voltage occurrence

Search Result 75, Processing Time 0.025 seconds

Development of High Voltage Generator for Diagnostic X-ray Equipment (진단용 X선 기기의 고전압 발생장치 개발)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.764-765
    • /
    • 2010
  • The medical treatment X-ray machineries used in diagnosis of the human body is possible to diagnosis inside of the human body with the method of noninvasive so that it has shared a very important role in diagnosis from the medical institution. High voltage occurrence system which is most important in occurrence of X-ray has mainly been used the existing type of high voltage transformer, however it has a low efficiency of X-ray occurrence since it is a big and heavy, and a high ripple ratio of the direct current high voltage come to the X-ray tube. In order to solve this problem, the research has been advanced about the high voltage power supply system, and the inverter type of the high voltage occurrence system which occurs a high voltage by increasing the power frequency from about ten times to about hundred times with the inverter has currently used mainly. Also, the operation of tube voltage and tube current was controlled by using PWM method and the operation results were identified using an oscilloscope.

  • PDF

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method (전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가)

  • Kim, Young-Pyo;Kim, Tae-Gon;Lee, Ho-Shik;Park, Yong-Pil;Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

A Study on the Arc Characteristics and Diagnosis of Electrical Contacts for Power due to Environmental Degree (환경오염도에 따른 전력용 전기접점의 아-크특성 및 진단에 관한 연구)

  • Lee, Jong-Ho;Hwang, Young-Han;Park, Hong-Tae;Lee, Kwang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.261-263
    • /
    • 1994
  • This paper deals with the on off arc characteristics of electromagnetic relay contacts contaminated by NaCl and $H_2SO_4$. In this paper, I have studied the characteristics of on-off voltage waveform. the contact errosion, contact surface analysis by SEM and EDAX under changed R-L parameter of testing circuit. After considers these result, I have tried to promote the diagnosis method and developed the contacts. As a results, (1) The arc duration and the numbers of arc occurrence characteristics are depended on contamination degree. The contamination degree is high when the arc characteristics is high. (2) Under clean condition, arc occurrence voltage, surge peak voltage, arc duration and the rate of contact errosion is lower than wet condition. (3) Surge peak voltage and arc duration is depended on L parameter. When L is High, the arc characteristics is high.

  • PDF

A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line (옥내 배전선로용 아크차단기 개발에 관한 연구)

  • Kwak, Dong-Kurl;Choi, Jung-Kyu;Park, Young-Jic;Kim, Jin-Hwan;Son, Jae-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

Characteristic Analysis of PD Occurrence Aspects for Defect of Stator Coil in HV Induction motor (고압 유도전동기 고정자권선의 결함에 따른 부분방전발생양상의 특징분석)

  • Lee, Kang-Won;Kim, Myung-Yong;Baik, Kwang-Sun;Jang, Dong-Uk;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2226-2228
    • /
    • 2005
  • High voltage induction motor is the important equipment for ensuring the driving performance of the electric train. PD(partial discharge) is a good indicator for showing the insulation performance of stator coil in HV induction motor. This paper has investigated the characteristics of PD occurrence aspects for both the sound and defective stator coil which consist of maximum PD amplitude(V), total occurrence number, average PD amplitude(V) and PD amplitude(v) - PD occurrence number(n). They were compared with each other depending on applied voltages and reconstructed to $60{\times}60$ matrices of PD amplitude(v)-occurrence phase (${\phi}$)-occurrence number(n) which is the good way to estimate the PD sources in stator coil.

  • PDF

Analysis on Current Limiting Characteristics of a Fault-lock Type SFCL Applied into a Simulated Power System (모의전력계통에 적용된 자속구속형 초전도 전류제한기의 전류제한 특성 분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.141-146
    • /
    • 2011
  • When the current of the superconducting element exceeds its critical current by the fault occurrence, the quench of the high-$T_C$ superconducting fault current limiter (HTSC) comprising the flux-lock type superconducting fault current limiter (SFCL) occurs. Simultaneously, the magnetic flux in the iron core induces the voltage in each coil, which contributes to limit the fault current. In this paper, the fault current limiting characteristics of the flux-lock type SFCL as well as the load voltage sag suppressing characteristics according to the flux-lock type SFCL's winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the flux-lock type SFCL were carried out. The flux-lock type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag suppressing operations through the fast quench occurrence right after the fault occurs and the fast recovery operation after the fault removes than the flux-lock type SFCL designed with the subtractive polarity winding.

Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System (자가 발전 시스템을 갖춘 고전압 전기장 수질개선 장치 개발)

  • Kang, Rae-Yun;Kang, Chul-Ung
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.

Temperature Distributions of Inner Microwave for Various Working Conditions (구동조건에 따른 전자레인지 내부 온도 분포)

  • Choi, Yoon-Hwan;Kim, Dong-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.792-797
    • /
    • 2010
  • Microwave oven and household cooker are devices of high voltage producer and high voltage storage batteries respectively for formation of necessary high frequencies at drive. These devices emit much heat energy because they are run at high voltages. Therefore, emitted heat energy becomes a factor that raises temperature of microwave ovens' main frame. In this research, the analysis shows the temperature distribution in microwave oven with the cooling fan drive conditions and the heat energy occurrence conditions. According to the analysis, as the speed of air outpoured in cooling fan increases, and the internal temperature decreases quantitatively. Also the inside temperature distribution was investigated by controlling heat energy emission.

A Study on Micom Algorithm Design for Prevention of Serial Parallel Arc Accident (직병렬아크사고 예방을 위한 마이컴 알고리즘 설계에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Choi, Shin-Hyeong;Jung, Do-Young;Kim, Dae-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.9-11
    • /
    • 2018
  • This paper studies on the development of an electric fire prevention system with the detection and alarm in case of parallel arc fault occurrence in low voltage distribution lines. The proposed detector has the characteristics of high speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. The line voltage is always feedback, and when an arc or a spark occurs, these are detected by the microcomputer. In addition, we design and develop algorithms using high speed and high precision microcomputer. A new conceptual control technique is adopted that RCD cuts-off by forming a forced short circuit between the phase voltage and ground in the event of an electrical accident. Some experimental tests of the proposed system also confirm practicality and the validity of the analytical results.

  • PDF