• 제목/요약/키워드: High voltage impulse

검색결과 192건 처리시간 0.028초

10/350 ${\mu}s$ 전류파형을 형성하기 위한 대용량 인덕터 특성 (Characteristics of High Energy Inductor to Generate Current Waveform of 10/350 ${\mu}s$)

  • 이태형;조성철;엄주홍;김기복
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.331-334
    • /
    • 2009
  • This paper presents the characteristics of external inductor for impulse current waveform with 10/350 ${\mu}s$ time parameters. Impulse generator was composed with capacitor having large capacitance and low working voltage for the safe of operator and small discharging sound. Parallel R-L-C circuits with crow-bar gaps and superposition method were proposed to make a high current lightning impulse according to IEC 62305-1. The high energy inductor with several taps for fitting half decay time T2 within the tolerance range and experimental data of inductance according to charging voltages were suggested.

  • PDF

고전압 임펄스 장치를 이용한 막오염 제어 연구 (Membrane fouling control using the high voltage impulse system)

  • 박수지;이주훈;장인성;강성미;이준호
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2005년도 춘계학술발표논문집
    • /
    • pp.272-273
    • /
    • 2005
  • 분리막 기술은 탁월한 처리효율뿐 아니라 안정적으로 용수를 생산할 수 있는 장점이 있기 때문에 용수의 생산을 전통적인 수처리 (Conventional water treatment) 공정에서 역삼투 공정(Reverse Osmosis) 및 나노여과 (Nanofiltration)와 같은 분리막 기술을 활용하는 공정으로 변환하는 추세에 있다. 그러나 분리막 공정은 항상 막오염 현상이 문제점으로 지목되고 있기 때문에 막오염 제어 기술의 확보가 시급한 실정이다. 따라서 본 연구에서는 화학물질의 사용에 따른 2차 환경오염 문제가 발생하는 화학약품이나 물리적인 세정이 아닌 고전압 임펄스 (HVI, High Voltage Impulse) 장치를 이용하여 막오염의 근본적인 문제를 제어하려 한다.

  • PDF

임펄스전류에 의한 대지표면전위상승 및 위험전압의 분석 (An Analysis of the Ground Surface Potential Rise and Hazardous Voltages Caused by Impulse Currents)

  • 이복희;이규선;최종혁;성창훈
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.117-123
    • /
    • 2011
  • Lightning and switching surges propagating through the grounding conductors lead to transient overvoltages, and electronic circuits in information technology systems are very susceptible to damage or malfunction from the electrical surges. Surge damages or malfunctions of electrical and electronic equipment may be caused by potential rises. To solve these problems, it is very important to evaluate the ground surface potential rises and hazardous voltages such as touch and step voltages at or near the grounding systems energized by electrical surges. In this paper, the performance of grounding systems against the surge current containing high frequency components on the basis of the actual-sized tests is presented. The ground surface potential rises and hazardous voltages depending on impulse currents for vertical or horizontal grounding electrodes are measured and analyzed. Also the touch and step voltages caused by the impulse currents are investigated. As a result, the ground surface potential rises, the touch and step voltages near the grounding electrodes are raised and the conventional grounding impedances are increased as the front time of the injected impulse currents is getting faster.

충격전압 재단과 측정을 위한 보상회로에 관한 연구 (A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse)

  • 김익수;김영배;김진기;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

배전피뢰기용 접지도선의 효과적인 설치기법 (Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors)

  • 이복희;강성만;유인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

고전압 펄스 전계의 인가전압과 온도가 수중 칼슘 농도 저감에 미치는 영향 (Effect of the applied voltage of pulsed electric fields and temperature on the reduction of calcium ion concentration)

  • 김재현;장인성
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.95-101
    • /
    • 2019
  • High voltage impulse(HVI) has been gained attention as an alternate technique controlling $CaCO_3$ scale formation. Investigation of key operational parameters for HVI is important, however, those had not been reported yet. In this study, the effect of temperature and applied voltage of HVI on $Ca^{2+}$ concentration was studied. As the applied voltage from 0 to 15kV and the temperature increased from 20 to $60^{\circ}C$, the $Ca^{2+}$ concentration decreased, indicating that the aqueous $Ca^{2+}$ precipitated to $CaCO_3$. The $Ca^{2+}$ concentration decreased up to 81% under the condition of 15kV and $60^{\circ}C$. Rate constant for the precipitation reaction, k was determined under different temper1ature and voltage. The reaction rate constant under the 15kV and $60^{\circ}C$ condition was evaluated to $66{\times}10^{-3}L/(mmol{\cdot}hr)$, which was 5 times greater than the k of the reaction without HVI at same temperature. The increases in k by HVI at higher temperature region(40 to $60^{\circ}C$) was much greater than at lower temperature region(20 to $40^{\circ}C$), which implies temperature is more important parameter than voltage for reducing $Ca^{2+}$ concentration at high temperature region. These results show that the HVI induction accelerates the precipitation to $CaCO_3$, particularly much faster at higher temperature.

고전압 임펄스 공정의 전계와 접촉시간이 Ca2+ 농도 저감에 미치는 영향의 속도론 연구 (Kinetic study about the effect of electric field and contact time of high voltage impulse on reduction of Ca2+ concentration)

  • 김담하;장인성
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.113-120
    • /
    • 2021
  • High voltage impulse (HVI) has been gained attention as an alternative technique that could control the CaCO3 scale problems encountered in water main, pipe, cooling tower and heat exchanger vessels. The aim of this study was to investigate the effect of electric field (E) and contact time (t) of HVI on reduction of Ca2+ concentration at two different temperatures of 25℃ and 60℃. A kinetic model on the effect of E and t was investigated too. As the E and t increased, the Ca2+ concentration decreased more than that of the control (= no HVI). The Ca2+ concentration decreased up to 81% at 15 kV/cm at 60℃, which was nearly 2 times greater than the control. With these experimental data-set of reduction of Ca2+ concentration under different E and t, the kinetic model was developed. The relationship between E and t required to reduce the concentration of Ca2+ by 30% was modeled at each temperature. The empirical model equations were; E0.83· t = 60.3 at 25℃ and E0.08· t = 1.1 at 60℃. These equations state the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increment of E and vice versa.

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

$SF_6$ 가스중 V-t절연파괴특성 (Voltage Time characteristic of electrical breakdown in $SF_6$)

  • 서길수;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

과도고전압측정에서 측정값 보정에 관한 연구 (RECONSTRUCTION OF HV IMPLUSES DEFORMED BY THE MEASURING SYSTEM)

  • 백용현;이국중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.153-156
    • /
    • 1990
  • High voltage impulse measuring system gives an output signal that is a deformed responce of the input signal. This paper describes a method of reconstructing the input signal from the deformed output. The method is applicable to any wave shape, full or chopped impulse voltages.

  • PDF