• 제목/요약/키워드: High voltage impulse

검색결과 192건 처리시간 0.031초

개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성 (Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구 (An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계 (Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

고전압 펄스의 수중인가 조건이 하이드록실 라디칼 생성에 미치는 영향 (Effect of operating conditions of high voltage impulse on generation of hydroxyl radical)

  • 조승연;장인성
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.611-618
    • /
    • 2017
  • Recently, applications of high voltage impulse (hereafter HVI) technique to desalting, sludge solubilization and disinfection have gained great attention. However, information on how the operating condition of HVI changes the water qualities, particularly production of hydroxyl radical (${\cdot}OH$) is not sufficient yet. The aim of this study is to investigate the effect of operating conditions of the HVI on the generation of hydroxyl radical. Indirect quantification of hydroxyl radical using RNO which react with hydroxyl radical was used. The higher HVI voltage applied up to 15 kV, the more RNO decreased. However, 5 kV was not enough to produce hydroxyl radical, indicating there might be an critical voltage triggering hydroxyl radical generation. The concentration of RNO under the condition of high conductivity decreased more than those of the low conductivities. Moreover, the higher the air supplies to the HVI reactor, the greater RNO decreased. The conditions with high conductivity and/or air supply might encourage the corona discharge on the electrode surfaces, which can produce the hydroxyl radical more easily. The pH and conductivity of the sample water changed little during the course of HVI induction.

고전압 임펄스를 적용한 막분리 공정에서의 생물막 오염 제어에 관한 연구 (A Study on the Biofouling Control in Membrane Processes Using High Voltage Impulse)

  • 이주훈;김준영;이진우;이준호;장인성
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.67-75
    • /
    • 2011
  • Although membrane technologies are widely applied to the water and wastewater treatment processes, strategy for the control of membrane biofouling is strongly required. In this study, a possibility of control of membrane biofouling using HVI(High Voltage Impulse) was verified based on the inactivation of microorganisms by the HVI. The HVI system was consisted of power supply, voltage amplifier, impulse generator and disinfection chamber and the model microorganism was E. coli. When 15[kV/cm] of electric fields was applied to the E. coli solution, inactivation of the microorganism was found. A possibility of the control of membrane biofouling using HVI was verified with experiments of membrane filtration with and without exposure of the HVI to biomass solution. Another membrane filtration experiments with the contaminated membranes by E. coli solution were carried out and indicate that the HVI could be used as an alternative method for membrane biofouling control. A series of simulation of the electric fields between electrodes and microorganisms was carried out for the visualization of the disinfection that showed where the electric fields are formed.

고전압 임펄스궤도회로의 동작특성 연구 (Study on the Operating Characteristics of High Voltage Impulse Track Circuit)

  • 이태훈;박기범;전용주;류영태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1279-1284
    • /
    • 2008
  • This paper presents the operating characteristic of high voltage impulse(HVI) track circuit owing to the ill-contact of impedance bond lead wire. The characteristic operations of the track include rail voltage and current. Measurements are carried out using oscilloscope with current probe and it analyzed the abnormal operation due to connector of protective wire. Finally, suitable track circuit is proposed for conventional line, and operating characteristic of HVI track circuit is affected by bypass circuit.

  • PDF

송전선로용 폴리머 피뢰기의 직렬공극 특성 (Series-Gap Characteristics of Polymeric Arrester for Transmission Line)

  • 조한구;유대훈;이용순;김종채
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

직류 피뢰기용 ZnO 소자의 전기적 특성 (The Electrical Characteristics of ZnO varistor for d.c. Arrester)

  • 김석수;최익순;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1106-1110
    • /
    • 2003
  • The electrical characteristics of $A{\sim}C's$ ZnO varistors fabricated according to variable sintering condition, which sintering temperature is $l130^{\circ}C$ and speeds of pusher are A: 2mm/min, B: 4mm/min, C: 6 mm/min, respectively, were investigated. The varistor voltage of $A{\sim}C's$ ZnO varistors sintered at $1130^{\circ}C$ increased in order A < B $A{\sim}C's$ ZnO varistors exhibited below 2mA at rated voltage. Lightning impulse residual voltage of A's ZnO varistor suited standard characteristics, which is 3.85kV at 2.5kA, 4.4kV at 5kA and 5.16kV at 10kA. After multi lightning impulse residual voltage test of A's ZnO varistor exhibited good discharge characteristics which ZnO varistor reveals no evidence of puncture, flashover, cracking in visual examination. After high current impulse test of A's ZnO varistor exhibited good discharge characteristics, which variation rate of residual voltage is 0.4% before and after test, and revealed no evidence.

  • PDF

액체질소 내에서 뇌 임펄스전압에 대한 압력별 GFRP의 절연파괴 특성 분석 (A Study on the Dielectric Characteristics of GFRP in LN2 under Lightning Impulse Voltage According to Pressure)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1471-1476
    • /
    • 2012
  • A study on the dielectric characteristics of the Glass Fiber Reinforced Plastic (GFRP) is important for designing a reliable high voltage superconducting machines such as transmission superconducting fault current limiters, superconducting cables, and superconducting transformers. In this paper, dielectric experiments of the GFRP under lightning impulse voltage are conducted in liquid nitrogen($LN_2$) according to various experimental conditions such as the thicknesses of the GFRP, the diameters of electrode systems and the pressures. The dielectric characteristics of the GFRP are analyzed by using a Finite Elements Method(FEM) according to various field utilization factors. It has been reported that the electrical insulation design of the GFRP would be conducted by considering the mean electric field intensity($E_{mean}$) distributed inside the GFRP. In this study, it is found that the dielectric performance of the GFRP could be explained by not only $E_{mean}$ but also the maximum electric field intensity ($E_{max}$). Finally, the empirical formulae of the GFRP to estimate an electrical breakdown voltage at sparkover under the lightning impulse condition are deduced. It is expected that the presented experimental results in this paper are helpful to design electrically reliable high voltage superconducting machines using the GFRP as an insulation material.

전철탑재형 직류피뢰기용 ZnO 바리스터의 개발 (A Development of ZnO Varistor for Railroad Vehicle d.c. Arrester)

  • 조이곤;박춘현;정세영;송태권;김석수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.552-556
    • /
    • 2002
  • The microstructure and electrical characteristics of A~C's ZnO varistors fabricated according to variable sintering condition, which sintering temperature is $1130^{\circ}C$ and speeds of pusher are A: 2mm/min, B: 4mm/min, C: 6mm/min, respectively, were investigated. In the microstructure, A~C's ZnO varist-ors fabricated variable sintering condition was consisted of ZnO grain(ZnO), spinel phase$(Zn_{2.33}Sb_{0.67}O_4)$ Bi-rich $phase(Bi_{2}O_{3})$, wholly. Varistor voltage of A~C's ZnO varistors sintered at $1130^{\circ}C$ increased in order A < B < C's ZnO varistors. C's ZnO varistor exhibited good characteristics that nonlinear exponent is 31.70. Leakage current of A~C's ZnO varistors exhibited below 2mA at rated voltage. Lightning impulse residual voltage of A's ZnO varistor suited standard characteristics, which is 3.85kV at 2.5kA, 4.4kV at 5kA and 5.16kV at 10kA. After multi lightning impulse residual voltage test of A's ZnO varistor exhibited good discharge characteristics which ZnO varistor reveals no evidence of puncture, flashover, cracking in visual examination. After high current impulse test of A's ZnO varistor exhibited good discharge characteristics, which variation rate of residual voltage is 0.4% before and after test, and revealed no evidence.

  • PDF