• Title/Summary/Keyword: High voltage apparatus

Search Result 146, Processing Time 0.034 seconds

Partial Discharge Pattern Recognition of Cast Resin Current Transformers Using Radial Basis Function Neural Network

  • Chang, Wen-Yeau
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.293-300
    • /
    • 2014
  • This paper proposes a novel pattern recognition approach based on the radial basis function (RBF) neural network for identifying insulation defects of high-voltage electrical apparatus arising from partial discharge (PD). Pattern recognition of PD is used for identifying defects causing the PD, such as internal discharge, external discharge, corona, etc. This information is vital for estimating the harmfulness of the discharge in the insulation. Since an insulation defect, such as one resulting from PD, would have a corresponding particular pattern, pattern recognition of PD is significant means to discriminate insulation conditions of high-voltage electrical apparatus. To verify the proposed approach, experiments were conducted to demonstrate the field-test PD pattern recognition of cast resin current transformer (CRCT) models. These tests used artificial defects created in order to produce the common PD activities of CRCTs by using feature vectors of field-test PD patterns. The significant features are extracted by using nonlinear principal component analysis (NLPCA) method. The experimental data are found to be in close agreement with the recognized data. The test results show that the proposed approach is efficient and reliable.

A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type (37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치)

  • 김학성;유동욱;임근희;완충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

Analysis and Design of High-Power, High-Frequency Charging Circuit using FB-ZVS Converter (FB-ZVS 콘버터를 이용한 대용량.고주파 충전회로의 해석 및 설계)

  • Lee, Ki-Young;Cha, Young-Kil;Jung, Jong-Jin;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.453-457
    • /
    • 1996
  • DC/DC converter is widely used in computer, electronic communication and industrial apparatus where the regulated dc supply is needed. FB-ZVS converter is suitable for high-power, high-frequency and constant frequency control. Because the voltage stress of the diode rectifier is high due to the ring effect, the clamp circuit is essential to reduce the voltage stress. The nondissipative active clamp circuit eliminates ring effect. Analysis of FB-ZVS converter and the validity of the active clamp circuit are studied through the simulation, and the experimental results show the superior characterics of the proposed system.

  • PDF

Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging (가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석)

  • Choi, Sun-Ho;Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

The Countermeasure about Harmonics of the High Voltage Power Facilities (고압수전설비의 고조파에 관한 대책)

  • Kim, Ju-Chan;Sin, Su-Han;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

Development of the Power Line Proximity Warning Apparatus for Mobile Crane using the Induced Voltage Measurement (유도전위 검출방식을 이용한 크레인의 고압 전선로 접근 경보장치 개발)

  • Choi, Sam-Jin;Park, Chan-Won;Kim, Il-Hwan
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.213-219
    • /
    • 2001
  • This paper describes the power line proximity warning device for mobile crane by using the induced voltage measurement method. A mobile crane worker can be easily exposed to dangerous electrical shock and the electrocution while this are working at near the high-voltage electrical lines. In this paper, the derivation electric-potential of the power lines are simulated and microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment.

  • PDF

Study about Electrical Insulation and earthing system of Bimodal Tram with Polymer Composite Body (고분자복합소재차체를 적용한 바이모달트램의 전기적 절연 및 접지시스템에 관한 연구)

  • Lee, Kang-Won;Mok, Jai-Kyun;Kil, Gyung-Suk;Park, Dae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1063-1064
    • /
    • 2008
  • Bimodal tram has a carbody made of polymer composite material which is good electrical insulator. As an series hybrid type, Alternating voltage generated from generator coupled with CNG engine are rectified and transformed to variable voltage ranges which are applied to electrical apparatus and ECUs equipped inside of the tram. The failures of electrical insulation between high voltage($400V{\sim}800V$) and low voltage(24V) or between different kind of voltages such as AC and DC may cause some electrical interferences to prevent from operating rightly and other safety problem. This paper have investigated about the degradation factors of the electrical insulation and the earthing method available to bimodal tram, which is effective for preventing the electromagnetic interference coming from the inside or outside of tram but need some detecting measurements of earth leakage through electrical systems.

  • PDF

Voltage Application Indicator Using Liquid Crystal Device (LCD를 이용한 통전상태 표시기 개발)

  • Koo, K.W.;Lyu, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF